Fluke 414D/62 MAX+ Laser Distance Meter/Infrared Thermometer Combo Kit

Fluke 414D/62 MAX+ Laser Distance Meter/Infrared Thermometer Combo Kit is rated 5.0 out of 5 by 2.
  • y_2024, m_12, d_1, h_7
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_2
  • loc_en_US, sid_fluke-414d-62-max-plus-kit, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 45.05ms
  • REVIEWS, PRODUCT
  • Fluke 414D/62 MAX+ Laser Distance Meter/Infrared Thermometer Combo Kit

Key Features

The 414D reduces errors, saves time and money

  • The most advanced laser technology for distance measurement
  • Measures up to 50 m (165 ft) with accuracy of 2 mm (0.08 in)
  • Quick calculation of area (square feet/meters) and volume 
  • Pythagoras function indirectly measures height via two other measurements
  • Stores up to five measurement results
  • Battery life of 3000 measurements with automatic shut-off feature

Fluke 62 MAX+. Small in size. Big on toughness

  • Dust and water-resistant: IP54 rated
  • Rugged: 3-meter (9.8-foot) drop tested
  • Ergonomically designed: Completely redesigned for a more natural hand fit
  • Distance to spot: 12:1
  • Dual lasers: Identifies area to be measured
  • Large, backlit display: Makes data easier to read, even in dark areas

Product overview: Fluke 414D/62 MAX+ Laser Distance Meter/Infrared Thermometer Combo Kit

The most rugged Fluke 62 MAX+ IR thermometer teamed with the easy to use 414D Laser Distance Meter has everything you need to configure layout and to troubleshoot electrical/hvac problems quickly. Use the IR thermometer to test for overheating in electrical devices and HVAC components, and use the laser distance meter to determine distance, area, and volume for space configuration.

Specifications: Fluke 414D/62 MAX+ Laser Distance Meter/Infrared Thermometer Combo Kit

Fluke 414D Laser Distance Meter

Distance Measurement
Typical Measuring Tolerance ¹±2.0 mm ³
Maximum Measuring Tolerance ²±3.0 mm ³
Range At Leica Target Plate GZM2650 m / 165 ft
Typical Range ¹40 m / 130 ft
Range At Unfavorable Condition 4 35 m / 115 ft
Smallest Unit Displayed1 mm / 1/16 in
Ø Laser Point At Distances6 / 30 / 60 mm
(10 / 50 / 100 m)
Tilt Measurement
Measuring Tolerance To Laser Beam 5 No
Measuring Tolerance To Housing 5 No
RangeNo
General
Laser Class2
Laser Type635 nm, < 1 mW
Protection ClassIP40
Automatic Laser OffAfter 90 seconds
Automatic Power OffAfter 180 seconds
Battery Life (2 x AAA) 1.5 V NEDA 24A/IEC LR03Up to 3,000 measurements
Size (L x W x D)116 x 53 x 33 mm
Weight (with batteries)113 g
Temperature Range:
Storage Operation
-25 °C to +70 °C (-13 °F to +158 °F)
0 °C to +40 °C (32 °F to +104 °F)
Calibration CycleNot applicable
Maximum Altitude3000 m
Maximum Relative Humidity85% at 20 °F to 120 °F (-7 °C to 50 °C)
SafetyIEC Standard No. 61010-1:2001
EN60825-1:2007 (Class II)
EMCEN 55022:2010
EN 61000-4-3:2010
EN 61000-4-8:2010
1. Applies for 100% target reflectivity (white painted wall), low background illumination, 25 °C.
2. Applies for 10 to 500% target reflectivity, high background illumination, -10 °C to +50 °C.
3. Tolerances apply from 0.05 m to 10 m with a confidence level of 95%. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m to 30 m and to 0.15 mm/m for distances above 30 m.
4. Applies for 100% target reflectivity, background illumination between 10'000 lux and 30'000 lux.
5. After user calibration. Additional angle related deviation of ±0.01 ° per degree up to ±45 ° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ±0.1 °

Fluke 62 MAX+ Infrared Thermometer

Specifications
Temperature Range-30 °C to 650 °C (-22 °F to 1202 °F)
Accuracy±1.0 °C or ±1.0% of reading, whichever is greater
-10 °C to 0 °C: ±2.0
-30 °C to -10 °C: ±3.0
Response Time (95%)Fluke 62 MAX+ < 300 ms (95% of reading)
Spectral response8 to 14 microns
Emissivity0.10 to 1.00
Optical Resolution12:1 (calculated at 90% energy)
Display Resolution0.1 °C (0.2 °F)
Repeatability Of Readings±0.5% of reading or < ±0.5 °C (1 °F), whichever is greater
PowerAA battery
Battery Life8 hours with laser and backlight on
Physical Specifications
Weight255 g (8.99 oz)
Size (L x W x D)175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in)
Operating Temperature0 °C to 50 °C (32 °F to 122 °F)
Storage Temperature (Without Battery)-20 °C to 60 °C (-4 °F to 140 °F)
Operating Humidity10% to 90% RH non-condensing at 30 °C (86 °F)
Operating Altitude2000 meters above mean sea level
Storage Altitude12,000 meters above mean sea level
IP RatingIP 54 per IEC 60529
Drop Test3 meters
Vibration And ShockIEC 68-2-6 2.5 g, 10 to 200 Hz
IEC 68-2-27, 50 g, 11 ms
EMCEN 61326-1:2006
EN 61326-2:2006
Standards And Agency Approval
ComplianceEN/IEC 61010-1: 2001
Laser SafetyFDA and EN 60825-1 Class II

Models: Fluke 414D/62 MAX+ Laser Distance Meter/Infrared Thermometer Combo Kit

414D/62 MAX+
Fluke 414D/62 MAX+ Laser Distance Meter/Infrared Thermometer Combo Kit

Buy it

Includes:

  • Fluke 414D Laser Distance Meter
  • Fluke 62 MAX+ IR Thermometer
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 51.38ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Rated 5 out of 5 by from This product has great features and works great We use this every day so glad that I purchased this.
Date published: 2016-12-07
Rated 5 out of 5 by from Goes The Distance We purchased the Fluke 414D Laser Distance Meter to make our jobs in the Facilities Department easier and more accurate. It has done both.
Date published: 2016-12-07
  • y_2024, m_12, d_1, h_7
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_2
  • loc_en_US, sid_fluke-414d-62-max-plus-kit, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 22.9ms
  • REVIEWS, PRODUCT
Please enable cookies to view product reviews.