Fluke 725Ex Series Process Calibrator

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 165.09ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • Fluke 725Ex Series Process Calibrator
  • Fluke 725Ex Series Process Calibrator
  • Video Player is loading.
    Current Time 0:00
    Duration 0:00
    Loaded: 0%
    Stream Type LIVE
    Remaining Time 0:00
     
    1x
      • Chapters
      • descriptions off, selected
      • captions off, selected
      1. Fluke 725Ex Series Process Calibrator
      2. Fluke 725Ex Series Process Calibrator
      3. Fluke takes product testing seriously
      Discontinued

      Key Features

      • Intrinsically safe multifunction process calibrator
      • Meets I.S. Class I, Division 1 Groups B-D, 171°C compliance standards
      • Measures volts DC, mA, RTDs, thermocouples, frequency, and ohms
      • Sources or simulates volts DC, mA, RTDs, thermocouples, frequency and ohms

      Product is available in the Middle East and Africa. Check availability with your distributor.

      This product is discontinued or reclassified

      Product overview: Fluke 725Ex Series Process Calibrator

      Fluke 725Ex provides an intrinsically safe, simple and powerful multifunction calibration solution

      The 725Ex is an intrinsically safe multifunction process calibrator for use in explosion endangered areas. It is powerful, yet easy to use. Combine the 725EX with any of the eight Fluke 750PEx Pressure Modules (sold separately), and you’ll be able to calibrate almost any process instrument likely to need service in an area where explosive gasses may be present.

      The 725EX sources and measures almost all process parameters including mA, volts, temperature (RTDs and thermocouples), frequency, ohms, and pressure, using optional pressure modules. Its split display lets you view input and output values simultaneously to calibrate transmitters. For valve and I/P tests, you can source mA while measuring pressure. The 725Ex has auto-stepping and auto-ramping for remote testing, plus 25% stepping for fast linearity tests.

      From the moment you pick it up, the Fluke 725Ex is ready to perform. Its simple controls, without menus, make operation easy. Its memory functions make set up fast. And its rugged design lets it work as hard as you do.

      Other useful features:

      • Pressure switch test function to capture set, reset, and deadband values
      • Small, streamlined shape, and rugged, reliable design that stands up to field use
      • Simple, push-button user interface for easy operation
      • Provides two-channel simultaneous source and measure capability to calibrate transmitters
      • Powers transmitters during test using loop supply
      • Stores frequently-used test setups for later use
      • Measures pressure to 3,000 psi/200 bar using any of the eight intrinsically safe Fluke 700PEx Pressure Modules to calibrate pressure transmitters and I/P devices

      What's in the box:

      • Fluke 725Ex Intrinsically Safe Multifunction Process Calibrator
      • (1 set) AC72 alligator clips
      • (1 pair) stackable test leads
      • (1 pair) TL75 test leads
      • NIST- traceable calibration report and data
      • Quick Reference Guide
      • 3-year warranty

      Specifications: Fluke 725Ex Series Process Calibrator

      Measurement Accuracy
      Voltage DC30.000 V0.02% + 2 counts (upper display)
      10.000 V0.02% + 2 counts (lower display)
      90.00 mV0.02% + 2 counts
      -10.00 mV to 75.00 mV0.025% + 1 count (via TC connector)
      Current DC24.000 mA0.02% + 2 counts
      Resistance0.0 to 400.0 Ω0.1 Ω (4-wire), 0.15 Ω (2- and 3-wire)
      401 to 1500 Ω0.5 Ω (4-wire), 1 Ω (2- and 3-wire)
      1500 to 3200 Ω1 Ω (4-wire), 1.5 Ω (2- and 3-wire)
      Frequency2.0 to 1000.0 CPM0.05% + 1 count
      1.0 to 1100.0 Hz0.05% + 1 count
      1.00 to 10.00 kHz0.05% + 1 count
      Sensitivity1 V peak-to-peak-minimum
      PressureAccuracy from 0.025% of range using any of 8 intrinsic safe pressure modules (for detailed specifications refer to pressure modules in options and accessories). Modules available for differential, gauge, vacuum, absolute, dual and high pressure.
      Source Accuracy
      Voltage DC100.00 mV0.02% + 2 counts
      10.000 V0.02% + 2 counts
      -10.00 mV to 75.00 mV0.025% + 1 count (via TC connector)
      Current DC24.000 mA (source)0.02% + 2 counts
      24.000 mA (simulate)0.02% + 2 counts
      Resistance15.0 to 400.0 Ω0.15 Ω (exc. current 0.15 to 0.5 mA), 0.1 Ω (exc. current 0.5 to 2 mA)
      401 to 1500 Ω0.5 Ω (excitation current 0.05 to 0.8 mA)
      1500 to 3200 Ω1 Ω (excitation current 0.05 to 0.4 mA)
      Frequency2.0 to 1000.0 CPM0.05%
      1.0 to 1100.0 Hz0.05%
      1.00 to 10.00 kHz0.25%
      Waveform5 V p-p squarewave, -0.1 V offset
      RTDs and Thermocouples
      Measure accuracyNI-1200.2°C
      PT-100 (385)0.33°C
      PT-100 (393)0.3°C
      PT-100 (JIS)0.3°C
      PT-200 (385)0.2°C
      PT-500 (385)0.3°C
      PT-1000 (385)0.2°C
      Resolution0.1°C
      J0.7°C
      K0.8°C
      T0.8°C
      E0.7°C
      R1.8°C
      S1.5°C
      B1.4°C
      L0.7°C
      U0.75°C
      N0.9°C
      ResolutionJ, K, T, E, L, N, U: 0.1°C, 0.1°F B, R, S: 1°C, 1°F
      XK0.6°C
      BP1.2°C
      Source accuracyNI-1200.2°C
      PT-100 (385)0.33°C
      PT-100 (393)0.3°C
      PT-100 (JIS)0.3°C
      PT-200 (385)0.2°C
      PT-500 (385)0.3°C
      PT-1000 (385)0.2°C
      Resolution0.1°C
       Accuracy stated for 4-wire measurement.
      J0.7°C
      K0.8°C
      T0.8°C
      E0.7°C
      R1.4°C
      S1.5°C
      B1.4°C
      L0.7°C
      U0.75°C
      N0.9°C
      ResolutionJ, K, T, E, L, N, U: 0.1°C, B, R, S: 1°C
      XK0.6°C
      BP1.2°C
      Specifications
      Ramp functionsSource functionsVoltage, current, resistance, frequency, temperature
      RampsSlow ramp, Fast ramp, 25% step-ramp
      Loop power functionVoltage12 V
      Accuracy10%
      Maximum current22 mA, short circuit protected
      Step functionsSource functionsVoltage, current, resistance, frequency, temperature
      Steps25% of range, 100% of range
      Safety specifications
      Agency approvalsI.S. Class I, Division 1 Groups B-D
      Mechanical and General Specifications
      Size130 x 236 x 61 mm (5.188 x 9.291 x 2.402 in)
      Weight0.85 kg (1.874 lbs.)
      Batteries4 AA alkaline batteries
      WarrantyThree year
      Battery replacementSeparate battery compartment, accessible without breaking calibration seal
      Side port connectionsPressure module connector

      Models: Fluke 725Ex Series Process Calibrator

      Fluke 725Ex
      Fluke 725Ex Intrinsically Safe Multifunction Process Calibrator

      Includes:

      • One set of AC72 alligator clips
      • One set of stackable test leads
      • One set of TL75 testleads
      • User manuals
      • NIST- traceable calibration report and data
      • bvseo_sdk, p_sdk, 3.2.1
      • CLOUD, getContent, 111.86ms
      • QUESTIONS, PRODUCT
      • bvseo-msg: HTTP status code of 404 was returned;
      • bvseo_sdk, p_sdk, 3.2.1
      • CLOUD, getReviews, 23.58ms
      • REVIEWS, PRODUCT
      • bvseo-msg: HTTP status code of 404 was returned;
      Please enable cookies to view product reviews.