Fluke ii900 Industrial Acoustic Imager

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 139.98ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • Fluke ii900 Industrial Acoustic Imager
  • Identify compressed air, gas and vacuum leaks
  • Video Player is loading.
    Current Time 0:00
    Duration 0:00
    Loaded: 0%
    Stream Type LIVE
    Remaining Time 0:00
     
    1x
      • Chapters
      • descriptions off, selected
      • captions off, selected
      • Video Player is loading.
        Current Time 0:00
        Duration 0:00
        Loaded: 0%
        Stream Type LIVE
        Remaining Time 0:00
         
        1x
          • Chapters
          • descriptions off, selected
          • captions off, selected
          • Visualize air and vacuum leaks, even when it is noisy
          • Find more compressed air, gas and vacuum leaks faster
          1. Fluke ii900 Industrial Acoustic Imager
          2. Identify compressed air, gas and vacuum leaks
          3. ii900 Sonic and Ultrasonic Leak Detector
          4. Fluke ii900 See Sound Video
          5. Visualize air and vacuum leaks, even when it is noisy
          6. Find more compressed air, gas and vacuum leaks faster
          Discontinued

          Key Features

          • NEW: Leak volume and cost indication on the go
          • NEW: CO2 emission reporting
          • Improve energy efficiency. Do more with the same air compressors and delay the capital expense of purchasing an additional compressor
          • Lower utility and downtime costs 
          • Reduce time and costs to detect leaks
          • Improve production process and pneumatic equipment reliability
          This product is discontinued or reclassified

          Product overview: Fluke ii900 Industrial Acoustic Imager

          Fluke Premium Care eligible

          When you invest in your Fluke test tools, you want your money to go as far as possible. Fluke Premium Care is a paid offering that provides coverage above and beyond the original product warranty, so you don’t need to worry about unexpected downtime caused by damaged test equipment, accessories, or tools in need of calibration or repair.

          Video Player is loading.
          Current Time 0:00
          Duration 0:41
          Loaded: 0%
          Stream Type LIVE
          Remaining Time 0:41
           
          1x
            • Chapters
            • descriptions off, selected
            • en (Main), selected

            Learn more

            Industrial imaging virtual demo

            How fast will you find your first leak?

            Right out of the box, the Fluke ii900 is ready to use. It’s rugged and ergonomic design make it easy to handle and the large 7” LCD display make leaks easy to see. Within minutes, a user with little-to-no experience can start detecting leaks. When the Fluke engineers were considering the users of the ii900, they wanted to make sure all the necessary components were built-in and easy to access. In addition, the Fluke engineers knew shutting down the plant or putting technicians in harm’s way was out of the question—that’s why they made sure the Fluke ii900 Industrial Acoustic Imager could be used in noisy environments and from a safe distance.

            You can actually see money leaking right out of your system

            A 100 hp air compressor can consume around $50k in electricity annually and as much as 30% of that electricity goes toward pressurizing airlines that leak. Many facilities have never assessed the efficiency of their compressed air operation and thus, when the system appears to be slowing down or not keeping up with demand, the facilities simply add more capacity. An expensive purchase considering compressed air systems should have relatively little change in capacity over time unless demand has increased, or the system is being sabotaged by leaks.

            More than you expected, by far

            • 7” LCD touchscreen that overlays a SoundMap™ on a visual image for quick leak location identification
            • Straightforward, intuitive interface to isolate the sound frequency of the leak and filter out loud background noise
            • Image and video tagging, annotation, and organization using folders
            • Leak sizing to help determine priority for repairs
            • Report tool to share visuals, tagging, notes, and more with others on your team or repair personnel

            Communication and reporting tools for everyone

            The Fluke ii900 comes enabled with LeakQ mode, which automatically determines the distance to the target (a leak that shows inside the circle on the display). When a leak is detected and the imager can determine the distance, the LeakQ value on the display gives in indication of the size of the leak. The value is based on the measured dB SPL value and the distance.

            The LeakQ reporting tool combines the inputs from your Fluke ii900 Industrial Acoustic Imager with inputs made directly to the tool to create organized and detailed reports. These reports can be used to convey where repairs need to be made, for follow-up post repair to confirm fixes, or for simply documenting the inspection process and results.

            How do you see sound?

            The Fluke ii900 Industrial Acoustic Imager visualizes the sounds coming from small leaks in compressed air, gas, and vacuum systems. Equipped with an array of microphones for an expanded field-of-view, the handheld Fluke ii900 Industrial Acoustic Imager (Sonic Industrial Imager) enables maintenance teams to locate air, gas, and vacuum leaks quickly and accurately in compressed air systems—even in noisy environments. Specifically designed for noisy production facilities the new SoundSight™ technology is simple to learn and easy to implement.

            What's in the box:

            • Fluke ii900 Industrial Acoustic Imager
            • AC power supply and battery pack charger (including universal AC adapters)
            • Two rugged lithium ion smart battery packs
            • USB cable
            • Rugged, hard carrying case
            • Adjustable hand strap and neck strap

            Specifications: Fluke ii900 Industrial Acoustic Imager

            Sensors
            # of microphones64 digital MEMS microphones
            Frequency band2 kHz to 52 kHz
            Sound pressure sensitivityDetects a 0.005 CFM leak at 100PSI from up to 32.8 feet
            (Detects a 2.5 cm3/sec leak at 7 bar from up to 10 meters)
            Operation distance range0.5 to > 70 meters (1.6 to > 164 feet)*
            Field of View63 ° ± 5 °
            Nominal frame rate25 FPS
            *Depending on ambient conditions
            Built-in digital camera (visible light)
            Field of View (FOV)63 ° ± 5 °
            FocusFixed lens
            Zoom3 x Digital Zoom
            Resolution1.2 MP
            Display7" LCD with backlight, under-sunlight readable
            Resolution1280 x 800 (1,024,000 pixels)
            TouchscreenCapacitive
            Acoustic ImageYes, SoundMap™ image
            Image storage
            Storage capacity20GB (>5000 pictures / >999 videos)
            Image formatBlended visual and SoundMap™.JPG or .PNG
            Video formatBlended visual and SoundMap™.MP4
            Video lengthUp to 5 minutes
            Digital exportUSB-C for data transfer
            Acoustic Measurements
            Sound pressure (typical)15.4 dB to 115.2 dB SPL (±1 dB) at 2 kHz
            5.6 dB to 102.5 dB SPL (±2 dB) at 19 kHz
            28.4 dB to 131.1 dB SPL (±1 dB) at 35 kHz
            41.8 dB to 133.1 dB SPL (±3 dB) at 52 kHz
            Auto max/min dB gainAuto or manual, user selectable
            Frequency band selectionUser selectable through user-made presets or manual entry
            Classification and quantificationLeakQ™
            Leak size and cost estimation
            Software
            Ease of useIntuitive user interface
            Trend graphsFrequency and dB scale
            Spot markersdB level reading at center point of the image
            Asset IDQR code based asset ID identification
            Asset Inspection Status:'As left', 'As found' ; 'Undetermined'
            Photo notesUp to 4 photos notes for reference
            SourceShow single or multiple sources
            ProfilePreset capture profiles
            Annotation:Asset name; Asset ID; Asset type; Leak type; Gas type; Pressure;
            OtherOperating conditions; Weather notes
            Leak valuesLeak costs; Leak volume; LeakQ™ scale
            Battery
            Batteries (field-replaceable, rechargeable)Rechargeable Li-ion
            Battery life6 hours (product includes spare battery)
            Battery charging time3 hours
            Battery charging systemExternal charger
            General Specifications
            Standard palettes3: Grayscale, Ironbow, Blue-Red
            Operating Temperature-10 °C to 45 °C (14 °F to 113 °F)
            Storage Temperature-20 °C to 70 °C (-4 °F to 158 °F) Without batteries
            Relative humidity10 % to 95 % non-condensing
            Size (H x W x L)186 mm x 322 mm x 68 mm (7.3 inches x 12.7 inches x 2.7 inches)
            Weight (battery included)1.8 kg (3.95 pounds)
            Ingress Protection (IP)IP40
            Warranty2 year
            Fluke Premium CarePremium Care Standard**
            Self-diagnostic notificationArray-health test to identify when microphone array needs attention
            Supported languagesDutch, English, Finish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese
            RoHS compliantYes
            ** Subject to regional availability 
            Safety
            General SafetyIEC 61010-1
            Electromagnetic Compatibility (EMC) InternationalIEC 61326-1: Portable Electromagnetic Environment IEC 61326-2-2
            CISPR 11: Group 1, Class A
            Korea (KCC)Class A Equipment (Industrial Broadcasting & Communication)
            USA (FCC)47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.

            Models: Fluke ii900 Industrial Acoustic Imager

            FLK-ii900

            Fluke ii900 Sonic Industrial Imager


            Includes:

            • Imager
            • AC power supply and battery pack charger (including universal AC adapters)
            • Two rugged lithium ion smart battery packs
            • USB cable
            • Rugged, hard carrying case
            • Adjustable hand strap and neck strap
            • bvseo_sdk, p_sdk, 3.2.1
            • CLOUD, getContent, 132.47ms
            • QUESTIONS, PRODUCT
            • bvseo-msg: HTTP status code of 404 was returned;
            • bvseo_sdk, p_sdk, 3.2.1
            • CLOUD, getReviews, 23.38ms
            • REVIEWS, PRODUCT
            • bvseo-msg: HTTP status code of 404 was returned;
            Please enable cookies to view product reviews.