Fluke 1652C Multifunction Installation Tester

Discontinued

Key Features

Read more
This product is discontinued or reclassified

Product overview: Fluke 1652C Multifunction Installation Tester

Extra functionality, faster testing, and as rugged as ever

The 1652C Installation Tester builds upon the rugged reputation of the earlier 1650 Series, only it’s re-designed to meet your need for more productive test tools.

This installation tester offers the following new capabilities:

  • Fast high current loop test
  • Variable RCD current mode for customized settings
  • PASS/FAIL indication for RCD tests
  • Select voltage measurement between L-N, L-PE and N-PE
  • Zero adapter for easy test lead compensation, available as new accessory and also included with standard scope of supply
  • Extended documentation mode (UK only)
Measurement functionsFluke 1652CFluke 1653BFluke 1654B
Voltage and frequency
Wiring polarity checker
Insulation resistance250 V, 500 V, 1000 V50 V, 100 V, 250 V,
500 V, 1000 V
50 V, 100 V, 250 V,
500 V, 1000 V
Continuity   
Loop and line resistance
Loop and line resistance-mΩ resolution  
PEFC/PSC (fault/short-circuit current)
RCD tripping time
RCD tripping current level
Ramp test
Automatic ROD test sequence
Test dc-sensitive RCDs (type A)
Test dc-sensitive RCDs (type B)  
Earth resistance 
Phase sequence indicator
Other features   
Self-test
EN 61557*/VDE 0413 compliant
Illuminated display
Live voltage indicator
Battery indicator and battery test function
Memory, interface   
Memory 
Extended memory  
Computer interface 
Time stamp (software enabled) 
Software (optional) 

Specifications: Fluke 1652C Multifunction Installation Tester

Specifications
AC voltage measurementRange500 V
Resolution0.1 V
Accuracy (50 - 60 Hz)±(0.8% + 3 digits)
Input impedance3.3 MΩ
Overload protection660 Vrms
Continuity testingRange (autoranging)20 Ω, 200 Ω, 2000 Ω
Resolution0.01 Ω, 0.1 Ω, 1 Ω
Test current> 200 mA
Open circuit voltage> 4 V
Accuracy±(1.5%+3 digits)
Insulation Resistance Measurement
Test voltageFluke 1652C250 - 500 - 1000 V
Fluke 1653B + 1654B50 - 100 - 250 - 500 - 1000 V
Test voltage (50 V)Test current1 mA @ 50 kΩ
Insulation range10 kΩ - 50 мΩ
Resolution0.01 мΩ
Accuracy±(3% + 3 digits)
Test voltage (100 V)Test current1 mA @ 100 kΩ
Range/Resolution20 MΩ/0.01 MΩ / 100 MΩ/0.1 MΩ 
Accuracy±(3% + 3 digits)
Test voltage ( 250 V)Test current1 mA @ 250 kΩ
Range/Resolution20 MΩ/0.01 MΩ /200 MΩ/0.1 MΩ 
Accuracy±(1.5% + 3 digits)
Test voltage (500 V)Test current1 mA @ 500 kΩ
Range/Resolution20 MΩ/0.01 MΩ
Range/Resolution200 MΩ/0.1 MΩ
Accuracy±(1.5% + 3 digits)
Range/Resolution500 MΩ/1 MΩ
Accuracy10%
Test voltage (1000 V)Test current1 mA @ 1 MΩ
Range/Resolution20 MΩ/0.01 MΩ
Range/Resolution200 MΩ/0.1 MΩ
Accuracy±(1.5% + 3 digits)
Range/Resolution500 MΩ/1 MΩ
Accuracy10%
Auto dischargeDischarge time constant, 0.5 second for C = 1 µF or less
Live circuit detectionInhibits test if terminal voltage > 30 V prior to initiation of test
Maximum capacitive loadOperable with the 5 µF load
Loop Impedance Measurement (High Current Mode and Non-Trip Mode)
 Range100 - 500 VAC (50/60 Hz)
Input connectionSoft Key selection
Loop impedancePhase to earth
Line impedancePhase to neutral
Limit on consecutive testsAutomatic thermal shutdown after 50 consecutive tests at 10 second intervals (typical)
  
Range/Resolution (High Current)20 Ω/0.001Ω (1mΩ) (Fluke 1654B)
Range/Resolution20 Ω/0.01 Ω
Range/Resolution200 Ω/0.1 Ω
Range/Resolution2000 Ω/1 Ω
  
Accuracy (no Trip mode)±(3% + 6 digits)
Accuracy (Hi Current mode)±(2% + 4 digits)
Accuracy (Hi Current mode 1mΩ)±(2% + 15 digits) (Fluke 1654B)
PFC, PSC TestComputationPFC or PSC determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance
Range0 - 25 kA
Resolution (Ik < 1000 A)1 A
Resolution (Ik >= 1000 A)0.1 kA
AccuracyDetermined by accuracy of loop resistance and mains voltage measurements.
RCD Testing ¹Fluke 1654BA, AC, B, B+, F, G/R, S
Fluke 1652CA, AC, F, G/R, S
Fluke 1653BA, AC, F, G/R, S
Tripping Time Test (ΔT)
Trip time accuracy ±(1% Reading + 1 digit)
Multiplier: x ½ Current Settings10, 30, 100, 300, 500, 1000 mA
Current Accuracy+0% - 10%
RCD Type ¹G
Measurement Range310 ms (Europe), 2000 ms (UK)
RCD Type ¹S
Measurement Range510 ms (Europe), 2000 ms (UK)
Multiplier: x 1Current Settings10, 30, 100, 300, 500, 1000 mA
Current Accuracy+10% - 0%
RCD Type ¹G
Measurement Range310 ms
RCD Type ¹S
Measurement Range510 ms
Multiplier: x 5Current Settings10, 30 mA
Current Accuracy±10%
RCD Type ¹G
Measurement Range50 ms
RCD Type ¹S
Measurement Range160 ms
Tripping Current (ramp)
Current range50% - 110% of RCD's rated current
Step Size10% of IΔN
Dwell time (Type G) ¹300 ms / step
Dwell time (Type S) ¹500 ms / step
Trip current measurement zccuracy±5%
Earth Resistance Test (RE) - Fluke 1653B + 1654B
Range/Resolution200 Ω/0.1 Ω
Accuracy±(2% + 5 digits)
Range/Resolution2000 Ω/1 Ω
Accuracy±(3.5% + 10 digits)
Frequency128 Hz
Compliance voltage+25 V
Phase Sequence Indication
IconIcon Phase Sequence indicator is active
Display of Phase SequenceDisplays '1-2-3' in digital display field for correct sequence
Displays '3-2-1' for incorrect phase
Dashes in place of a number indicate a valid determination could not be made
¹ RCD Types
GGeneral, no delay
STime delay
AResponds to pulsed signal
ACResponds to AC
1654B 
Environmental Specifications
Operating temperature-10 °C to 40 °C
Humidity (without condensation)10 to 30 °C95%
30 to 40 °C75%
Safety Specifications
Safety RatingEN 61010-I CAT III 500V, CAT IV 300V
Mechanical and General Specifications
Size (L x W x H)10 x 25 x 12.5 cm
Weight1.3 kg
BatteriesType AA: 6
Warranty3 years
Battery typeAlkaline supplied, usable with 1.2V NiCD or NiMH rechargeable batteries

Models: Fluke 1652C Multifunction Installation Tester

Fluke 1652C
Fluke 1652C Multifunction Installation Tester

  • 6 AA Cell batteries
  • C1600 Hard carrying case
  • Zero Adapter
  • Mains test cord
  • TL165X/STD Standard Test Lead Set
  • Padded carrying strap
  • Quick reference guide
  • TP165X Remote control probe and lead¹
  • Users manual on CD-ROM