Fluke T6-1000 Electrical Tester

Fluke T6-1000 Electrical Tester is rated 4.0 out of 5 by 35.
  • y_2025, m_3, d_22, h_10
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_5, tr_30
  • loc_en_US, sid_3739311243316, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 22.49ms
  • REVIEWS, PRODUCT
  • T6-1000 Electrical Tester
  • T6-1000 Electrical Tester - 2
  • T6-1000 Electrical Tester - 3
  • Fluke T6-1000 Electrical Tester
  • Video Player is loading.
    Current Time 0:00
    Duration 1:56
    Loaded: 0%
    Stream Type LIVE
    Remaining Time 1:56
     
    1x
      • Chapters
      • descriptions off, selected
      • captions off, selected
      • en (Main), selected
    1. T6-1000 Electrical Tester
    2. T6-1000 Electrical Tester - 2
    3. T6-1000 Electrical Tester - 3
    4. Fluke T6-1000 Electrical Tester
    5. Make FieldSense measurements correctly

    Key Features

    • Measure voltage to 1000 V AC without test leads
    • Simultaneously measure voltage and current
    • 17.8 mm open fork is widest in the industry
    • Measure up to 200 A on 4/0 wires (120 mm2)

    Product overview: Fluke T6-1000 Electrical Tester

    Measure voltage without test leads

    The Fluke T6-1000 Electrical Tester with FieldSense™ technology lets you quickly, safely take True rms voltage and current measurements without test leads.

    Unlike other fork testers that merely detect voltage, the T6-1000 makes actual measurements, without contacting a live, metallic conductor. Just slide the 17.8 mm open fork, the widest in the industry, over a conductor and read simultaneous voltage and current values. Or simultaneous frequency and current values. The open fork works with wires up to AWG 4/0 (120 mm2). Or, you can use the attached test leads to measure voltage DC to 1000 V.

    • True rms voltage and current to 200 A AC, 1000 V AC
    • Resistance 1 Ω to 100 kΩ

    Work on any jobsite

    Make use of the HOLD button to temporarily freeze the reading on the screen so you can keep working with the same measurement up. Plus, the display features large, easy-to-read numbers and a backlight for darker work environments or inside cabinets. The T6-1000 works with the Fluke TPACK ToolPak™ Magnetic Meter Hanger to make it even more convenient.

    How FieldSense™ technology works

    FieldSense ™ technology is different than other open fork testers work by interpreting a magnetic field to show AC current. FieldSense™ detects an electrical field that interacts with a T6 reference signal, showing a voltage value on the tester’s display.

    FieldSense tools

    Learn how to use the T6
    Download the Quick Reference Guide
    Download the T6 "How-To" Demonstration Guide
    Read the FieldSense Proving Unit Demonstration Guide

    FieldSense tools

    T6 Electrical Tester Helps Team at Cutting Edge Cancer Research Center

    T6 Awards

    PTIA 2018 Awards Winner

    2017 NECA Showstopper H18 Innovation Awards Winner

    Dealer Design Award 2018

    What's in the box:

    • T6-1000 Electrical Tester
    • Attached test leads with removable 4 mm probe caps
    • Quick Reference Guide

    Specifications: Fluke T6-1000 Electrical Tester

    Measurement Specifications
    FunctionRequires test leadsRangeResolutionAccuracy[1]
    FieldSense
    ac voltage true-rms
    No1000 V1 V± (3 % + 3 counts) 45 Hz - 66 Hz[2][3]
    FieldSense
    ac current true-rms
    No200.0 A0.1 A± (3% + 3 counts) 45 Hz - 66 Hz
    FieldSense
    frequency (Hz)
    No45 Hz – 66 Hz1 Hz± (1% + 2 counts)[3]
    Volts ac true-rmsYes1000 V1 V± (1.5% + 2 counts) 45 Hz - 66 Hz
    Volts dcYes1000 V1 V± (1% + 2 counts)
    ResistanceYes2000 Ω1 Ω± (1% + 2 counts)
    Yes20.00 kΩ0.01 kΩ
    Yes100.0 kΩ0.1 kΩ
    Safety 1000 V CAT III
    600 V CAT IV
      
    Accuracy[1]: ± ( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC measurements are ac-coupled, RMS responding.
    Accuracy[2]: Add 3 % without an external ground connection. External ground connection required for user wearing insulated gloves, standing on an insulated ladder, or otherwise insulated from earth ground.
    Accuracy[3]: FieldSense is specified from 16 V to 100 % of range.
    General Specifications
    Calibration1-year calibration cycle
    Dimensions61.1 x 259.3 x 43.8 mm
    Jaw opening17.8 mm
    Weight0.35 kg (0.78 lb)
    TemperatureOperating-10 °C to +50 °C (14 °F to 122 °F)
    Storage-30 °C to +60 °C (-22 °F to +140 °F)
    AltitudeOperating2,000 m (6,562 feet)
    Storage10,000 m (32,808 feet)
    Relative Humidity0% to 90%, 5 °C to 30 °C (41 °F to 86 °F)
    0% to 75%, 30°C to 40 °C (86 °F to 104 °F)
    0% to 45%, 40°C to 50 °C (104 °F to 122 °F)
    Battery Type and Life2 x AA (IEC LR6); 360 hours continuous, typical; 200 hours using FieldSense
    Temperature coefficient0.1 x (specified accuracy) / °C for <18°C or >28 °C
    0.1 x (specified accuracy) / °C for <18°C or >28 °C
    SafetyIEC/EN 61010-1: Pollution Degree 2
    Electromagnetic EnvironmentIEC/EN 61326-1: Portable

    Models: Fluke T6-1000 Electrical Tester

    T6-1000 Electrical Tester

    Buy it

    Includes:

    • Attached test leads with removable 4 mm probe caps
    • User documentation
    • bvseo_sdk, p_sdk, 3.2.1
    • CLOUD, getContent, 23.16ms
    • QUESTIONS, PRODUCT
    • bvseo-msg: HTTP status code of 404 was returned;
    • y_2025, m_3, d_22, h_10
    • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
    • cp_1, bvpage1
    • co_hasreviews, tv_5, tr_30
    • loc_en_US, sid_3739311243316, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
    • clientName_fluke
    • bvseo_sdk, p_sdk, 3.2.1
    • CLOUD, getReviews, 22.36ms
    • REVIEWS, PRODUCT
    Please enable cookies to view product reviews.