Fluke Calibration 1524 Handheld Thermometer Readout
Key Features
- Measure, graph, and record PRTs, thermocouples, and thermistors, supporting a wide range of temperature sensors.
- Accuracy up to ±0.002 °C.
- Quick sample readings in as little as 0.3 seconds.
- 1524 has two channels for simultaneous measurements, doubling productivity.
Product overview: Fluke Calibration 1524 Handheld Thermometer Readout
Make accurate, consistent measurements… anywhere.
You need accuracy for compliance, product yields, energy savings, and consistent results. The 1524 uses current reversal, a technique used in high-end instruments that eliminates thermal EMFs, for precision temperature measurements. Specifications are guaranteed from -10 °C to 60 °C ambient. Special precision resistors and a highly stable reference voltage source keep 1524 accuracy virtually insensitive to environmental temperature.
Like all Fluke handheld tools, the 1524 Reference Thermometers endure rigorous testing in temperature extremes and under harsh conditions of vibration, so you can take them anywhere you need to go.
An optional magnetic hanger allows you to hang the thermometer for easy viewing while freeing your hands to focus on the job.
INFO-CON connectors ensure correct temperature conversion
Inside the INFO-CON, a memory chip keeps calibration information for the attached probe. Simply plugging in the probe uploads the information to the readout, ensuring the correct temperature conversion for accurate, hassle-free measurements.
Probes may be locked by password to specific channels and readouts for security or for system calibration traceability. Plug any thermocouple with mini-thermocouple jacks into an optional universal thermocouple adapter for convenient measurement. Each thermocouple adapter or standard connector supports reference junction compensation (RJC) with its own internal precision thermistor.
Monitor trends in the lab or in the field
See trends graphically on the 1524 thermometer’s 128x64-backlit LCD display. You can change the graph’s resolution at the touch of a button. Now it’s easy to see when the temperature is stable, without statistics or long delays, or monitor processes over time to verify correct operation.
Document on demand up to 25 readings and associated statistics for easy retrieval. You can view the data through the display or by uploading it to a PC via RS-232 connection and 9940 software, included free. To monitor and log more data over time, use a PC and optional LogWare II software.
RS-232-to-USB adapters are available for those who prefer USB connectors. Battery power lasts at least 20 hours on three AA batteries, or use the dc power adapter for extended periods of measurement. Power saving features can be enabled or disabled for longer battery life or greater convenience.
Applications
The new 1524 Reference Thermometers help you do twice the work in half the time. Two channels and three sensor types and high-speed measurement make you more productive and make model 1524 the one reference thermometer you need to own. It has all the features of the 1523, and it’s a data logger too. A real-time clock and memory for 15,000 time and date stamped measurements mean everything you are going to need is in this package. Log up to three times per second, or once every hour or other options in between. Download the data to a PC for analysis when you need it.
Calibration, loop checking, plant startup, troubleshooting, maintenance, and repair are some of the varied duties that need a 1524 thermometer. Use it for a handy temperature reference in baths, dry-block calibrators, thermowells, clean rooms, engines, heat exchangers, furnaces, freezers, or anything else that must be calibrated, checked, or maintained.
Specifications: Fluke Calibration 1524 Handheld Thermometer Readout
Specifications | |
Input channels | 2 |
Logging | 15,000 time and date stamped; 25 readings with statistics |
Sample interval (normal) | 1 second |
Sample interval (fast mode) | 0.3 seconds (see technical manual for details) |
Sensor types | PRTs, RTDs, thermistors, and thermocouples |
Thermocouple types | C, E, J, K, L, M, N, T, U, B, R, S |
Operating temperature | -10°C to 60°C (Best accuracy 13°C to 33°C) |
Power requirements | 3 AA alkaline batteries |
Size | 96 x 200 x 47 mm (3.75 x 7.9 x 1.86 in) |
Weight | 0.65 kg (1.4 lb) |
Environmental conditions for best accuracy | 13°C to 33°C |
Millivolt range and accuracy | –10 mV to 75 mV ±(0.005% + 5 μV) |
Resistance range and accuracy | 0 Ω to 400 Ω ±(0.004% + 0.002 Ω) 200 Ω to 50 kΩ ±(0.01% + 0.5 Ω) 50 kΩ to 500 kΩ ± (0.03%) |
Temperature coefficient, voltage (–10°C to 13°C, +33°C to 60°C) | ±(0.001%/°C + 1 μV/°C) |
Temperature coefficient, resistance (–10°C to 13°C, +33°C to 60°C) | 0.0008%/°C + 0.0004 Ω (0 Ω to 400 Ω) 0.002%/°C + 0.1 Ω (0 Ω to 50 kΩ) 0.06%/°C + 0.1 Ω (50 kΩ to 500 kΩ) |
Excitation current, resistance | 1 mA (0 Ω to 400 Ω) 10 μA (0 Ω to 50 kΩ) 2 µA (50 kΩ to 500 kΩ) |
Thermocouple Equivalent Temperature Accuracies (Readout Only) | |
Type B | ±0.85°C from 600°C to 800°C ±0.68°C from 800°C to 1000°C ±0.57°C from 1000°C to 1800°C |
Type C | ±0.32°C from 100ºC to 550°C ±0.71°C from 550°C to 2300°C |
Type E | ±0.52°C from -200°C to 0°C ±0.22°C from 0°C to 950°C |
Type J | ±0.52°C from -200°C to 0°C ±0.23°C from 0°C to 1200°C |
Type K | ±0.61°C from -200°C to 0°C ±0.24°C from 0°C to 1370°C |
Type L | ±0.36°C from -200°C to 0°C ±0.23°C from 0°C to 1370°C |
Type M | ±0.26°C from -20°C to 0°C ±0.25°C from 0°C to 400°C ±0.22°C from 400°C to 1400°C |
Type N | ±0.72°C from -200°C to 0°C ±0.28°C from 0°C to 1300°C |
Type R | ±1.09°C from -20°C to 0°C ±0.97°C from 0°C to 500°C ±0.49°C from 500°C to 1750°C |
Type S | ±1.05°C from -20°C to 0°C ±0.95°C from 0°C to 500°C ±0.56°C from 500°C to 1750°C |
Type T | ±0.60°C from -200°C to 0°C ±0.25°C from 0°C to 400°C |
Type U | ±0.54°C from -200°C to 0°C ±0.24°C from 0°C to 400°C |
Accuracies are based on internal reference junction compensation. Refer to technical manual for equivalent accuracies with an external reference junction. | |
1524 Accuracies with Selected Probes (±°C) | |
-200°C | 5616-12: 0.014 5615-6: 0.025 5627A-12: 0.027 5610-9: n/a |
0°C | 5616-12: 0.021 5615-6: 0.021 5627A-12: 0.049 5610-9: 0.009 |
100°C | 5616-12: 0.027 5615-6: 0.028 5627A-12: 0.065 5610-9: 0.009 |
300°C | 5616-12: 0.040 5615-6: 0.043 5627A-12: 0.103 5610-9: n/a |
420°C | 5616-12: 0.050 5615-6: n/a 5627A-12: 0.130 5610-9: n/a |
Includes readout accuracy, probe calibration, and probe drift | |
PRT Equivalent Temperature Accuracy (Readout only) | |
–100°C | ±0.011 |
0°C | ±0.015 |
100°C | ±0.019 |
200°C | ±0.023 |
400°C | ±0.031 |
600°C | ±0.039 |
Thermistor Equivalent Temperature Accuracy (Readout Only) | |
0°C | ±0.002 |
25°C | ±0.003 |
50°C | ±0.006 |
75°C | ±0.014 |
100°C | ±0.030 |
Models: Fluke Calibration 1524 Handheld Thermometer Readout
Fluke Calibration 1524-156 Handheld Thermometer Readout
2 Channel, Data Logger, 17025 Accredited Calibration
For 1524 packages with PRTs below,
please contact us
1524 Bundled with 5628 PRT
Includes:
- 5628 PRT
- Universal TC INFO-CON Connector
- TPAK
- Case
1524 Bundled with 5627A PRT
Includes:
- 5627A PRT
- Universal TC INFO-CON Connector
- TPAK
- Case
1524 Bundled with 5615 PRT
Includes:
- 5616 PRT
- Universal TC INFO-CON Connector
- TPAK
- Case
System Verification, PRT with Readout, Accredited.
Choose two temperature points, extra points at additional cost. Available temperature points are –197 °C, -80 °C , –39 °C, 0.01°C, 30 °C, 157 °C, 232 °C, 300 °C, 420 °C, 500 °C, 660 °C.
System Verification, Thermistor with Readout, Accredited.
Choose two temperature points; extra points at additional cost. Available temperature points are -30 °C, -20 °C, -10 °C, 0 °C, 10 °C, 20 °C, 30 °C, 40 °C, 50 °C, 60 °C, 70 °C, 80 °C, 90 °C, 100 °C.
System Calibration, Thermistor with Readout, NVLAP-accredited
Choose thermistor temperature range for the calibration. Available temperature ranges are 100 °C span (6 points over span), 60 °C span (7 points over span), 100 °C span (11 points over span).