6022/6024 High Temperature Calibration Oil Baths

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 53.91ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • 6022/6024 High Temperature Calibration Oil Baths
Discontinued
This product is discontinued or reclassified

Product overview: 6022/6024 High Temperature Calibration Oil Baths

Comparison calibrations require a heat source that’s stable and uniform, and for moderately high temperatures nothing provides a better heat source than a Fluke Calibration oil bath.

Fluke Calibration oil baths are stable to ±0.001 °C and do not require calibration blocks or use of special calibration techniques to achieve that stability. The specifications of all our baths are “true specifications representing the performance you can expect to achieve in your lab under your operating conditions. Other companies advertise specs that they know you will never see in your lab. When their baths fail to perform, they blame it on you.

Fluke Calibration baths are built using a unique tank design that guarantees the best uniformity possible in a liquid bath. This, coupled with the industry’s best-selling digital bath controller, achieves uncompromised performance and ease of use.

Not only does our digital controller have features like its “Super-Tweak high-resolution mode so you can dial in the exact temperatures you want, it also lets you completely automate the calibration process using your PC and our 9938 MET/TEMP II software.

You’ll love these baths, and once you’ve got one you’ll never buy anything else. There’s a bath to match any temperature range, depth, price, and performance you need.

Specifications: 6022/6024 High Temperature Calibration Oil Baths

Specifications
 60226024
Range40 °C to 300 °C
Stability±0.001 °C at 40 °C (water)
±0.003 °C at 100 °C (oil 5012)
±0.005 °C at 300 °C (oil 5017)
Uniformity±0.002 °C at 40 °C (water)
±0.004 °C at 100 °C (oil 5012)
±0.012 °C at 300 °C (oil 5017)
Temperature SettingDigital display with push-button data entry
Set-Point Resolution0.01 °C; high-resolution mode, 0.00018 °C
Display
Temperature Resolution
0.01 °C
Digital Setting Accuracy±1 °C
Digital Setting Repeatability±0.02 °C
Heaters350 and 1050 watts
Access Opening
(call for custom openings)
127 x 254 mm (5 x 10 in)184 x 324 mm
(7.25 x 12.75 in)
Depth464 mm (18.25 in)337 mm (13.25 in)
Wetted Parts304 stainless steel
Power115 VAC (±10 %), 50/60 Hz, 10 A or 230 VAC (±10 %), 50/60 Hz, 5 A, specify
Volume42 liters (11.2 gallons)
Weight36 kg (80 lb.)
Size (HxWxD)813 x 406 x 508 mm
(32 x 16 x 20 in)
699 x 483 x 584 mm
(27.5 x 19 x 23 in)
Automation PackageMetTemp II software and RS-232 computer interface are included for setting bath temperature via remote computer. For IEEE-488, add the 2001-IEEE.

External cooling required for operation below 40 °C. Cooling coils are built into the

Models: 6022/6024 High Temperature Calibration Oil Baths

6024
Standard Bath, 40 °C to 300 °C, deep

6022
Standard Bath, 40 °C to 300 °C, high capacity

2001-IEEE

IEEE-488 Interface, 6330/7320/7340


  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 23.69ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 23.14ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.