Fluke ii900 Industrial Acoustic Imager

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 27.82ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • Fluke ii900 Industrial Acoustic Imager
  • Identify compressed air, gas and vacuum leaks
  • Visualize air and vacuum leaks, even when it is noisy
  • Find more compressed air, gas and vacuum leaks faster

Key features

  • NEW: Leak volume and cost indication on the go
  • NEW: CO2 emission reporting
  • Improve energy efficiency. Do more with the same air compressors and delay the capital expense of purchasing an additional compressor
  • Lower utility and downtime costs 
  • Reduce time and costs to detect leaks
  • Improve production process and pneumatic equipment reliability

Product overview: Fluke ii900 Industrial Acoustic Imager

Industrial imaging virtual demo

How fast will you find your first leak?

Right out of the box, the Fluke ii900 is ready to use. It’s rugged and ergonomic design make it easy to handle and the large 7” LCD display make leaks easy to see. Within minutes, a user with little-to-no experience can start detecting leaks. When the Fluke engineers were considering the users of the ii900, they wanted to make sure all the necessary components were built-in and easy to access. In addition, the Fluke engineers knew shutting down the plant or putting technicians in harm’s way was out of the question—that’s why they made sure the Fluke ii900 Industrial Acoustic Imager could be used in noisy environments and from a safe distance.

You can actually see money leaking right out of your system

A 100 hp air compressor can consume around $50k in electricity annually and as much as 30% of that electricity goes toward pressurizing airlines that leak. Many facilities have never assessed the efficiency of their compressed air operation and thus, when the system appears to be slowing down or not keeping up with demand, the facilities simply add more capacity. An expensive purchase considering compressed air systems should have relatively little change in capacity over time unless demand has increased, or the system is being sabotaged by leaks.

More than you expected, by far

  • 7” LCD touchscreen that overlays a SoundMap™ on a visual image for quick leak location identification
  • Straightforward, intuitive interface to isolate the sound frequency of the leak and filter out loud background noise
  • Image and video tagging, annotation, and organization using folders
  • Leak sizing to help determine priority for repairs
  • Report tool to share visuals, tagging, notes, and more with others on your team or repair personnel

Communication and reporting tools for everyone

The Fluke ii900 comes enabled with LeakQ mode, which automatically determines the distance to the target (a leak that shows inside the circle on the display). When a leak is detected and the imager can determine the distance, the LeakQ value on the display gives in indication of the size of the leak. The value is based on the measured dB SPL value and the distance.

The LeakQ reporting tool combines the inputs from your Fluke ii900 Industrial Acoustic Imager with inputs made directly to the tool to create organized and detailed reports. These reports can be used to convey where repairs need to be made, for follow-up post repair to confirm fixes, or for simply documenting the inspection process and results.

How do you see sound?

The Fluke ii900 Industrial Acoustic Imager visualizes the sounds coming from small leaks in compressed air, gas, and vacuum systems. Equipped with an array of microphones for an expanded field-of-view, the handheld Fluke ii900 Industrial Acoustic Imager (Sonic Industrial Imager) enables maintenance teams to locate air, gas, and vacuum leaks quickly and accurately in compressed air systems—even in noisy environments. Specifically designed for noisy production facilities the new SoundSight™ technology is simple to learn and easy to implement.

What's in the box:

  • Fluke ii900 Industrial Acoustic Imager
  • AC power supply and battery pack charger (including universal AC adapters)
  • Two rugged lithium ion smart battery packs
  • USB cable
  • Rugged, hard carrying case
  • Adjustable hand strap and neck strap

Specifications: Fluke ii900 Industrial Acoustic Imager

Sensors
# of microphones64 digital MEMS microphones
Frequency band2 kHz to 52 kHz
Sound pressure sensitivityDetects a 0.005 CFM leak at 100PSI from up to 32.8 feet
(Detects a 2.5 cm3/sec leak at 7 bar from up to 10 meters)
Operation distance range0.5 to > 70 meters (1.6 to > 164 feet)*
Field of View63 ° ± 5 °
Nominal frame rate25 FPS
*Depending on ambient conditions
Built-in digital camera (visible light)
Field of View (FOV)63 ° ± 5 °
FocusFixed lens
Zoom3 x Digital Zoom
Resolution1.2 MP
Display7" LCD with backlight, under-sunlight readable
Resolution1280 x 800 (1,024,000 pixels)
TouchscreenCapacitive
Acoustic ImageYes, SoundMap™ image
Image storage
Storage capacity20GB (>5000 pictures / >999 videos)
Image formatBlended visual and SoundMap™.JPG or .PNG
Video formatBlended visual and SoundMap™.MP4
Video lengthUp to 5 minutes
Digital exportUSB-C for data transfer
Acoustic Measurements
Sound pressure (typical)15.4 dB to 115.2 dB SPL (±1 dB) at 2 kHz
5.6 dB to 102.5 dB SPL (±2 dB) at 19 kHz
28.4 dB to 131.1 dB SPL (±1 dB) at 35 kHz
41.8 dB to 133.1 dB SPL (±3 dB) at 52 kHz
Auto max/min dB gainAuto or manual, user selectable
Frequency band selectionUser selectable through user-made presets or manual entry
Classification and quantificationLeakQ™
Leak size and cost estimation
Software
Ease of useIntuitive user interface
Trend graphsFrequency and dB scale
Spot markersdB level reading at center point of the image
Asset IDQR code based asset ID identification
Asset Inspection Status:'As left', 'As found' ; 'Undetermined'
Photo notesUp to 4 photos notes for reference
SourceShow single or multiple sources
ProfilePreset capture profiles
Annotation:Asset name; Asset ID; Asset type; Leak type; Gas type; Pressure;
OtherOperating conditions; Weather notes
Leak valuesLeak costs; Leak volume; LeakQ™ scale
Battery
Batteries (field-replaceable, rechargeable)Rechargeable Li-ion
Battery life6 hours (product includes spare battery)
Battery charging time3 hours
Battery charging systemExternal charger
General Specifications
Standard palettes3: Grayscale, Ironbow, Blue-Red
Operating Temperature-10 °C to 45 °C (14 °F to 113 °F)
Storage Temperature-20 °C to 70 °C (-4 °F to 158 °F) Without batteries
Relative humidity10 % to 95 % non-condensing
Size (H x W x L)186 mm x 322 mm x 68 mm (7.3 inches x 12.7 inches x 2.7 inches)
Weight (battery included)1.8 kg (3.95 pounds)
Ingress Protection (IP)IP40
Warranty2 year
Fluke Premium CarePremium Care Standard**
Self-diagnostic notificationArray-health test to identify when microphone array needs attention
Supported languagesDutch, English, Finish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese
RoHS compliantYes
** Subject to regional availability 
Safety
General SafetyIEC 61010-1
Electromagnetic Compatibility (EMC) InternationalIEC 61326-1: Portable Electromagnetic Environment IEC 61326-2-2
CISPR 11: Group 1, Class A
Korea (KCC)Class A Equipment (Industrial Broadcasting & Communication)
USA (FCC)47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.

Models: Fluke ii900 Industrial Acoustic Imager

FLK-ii900

Fluke ii900 Sonic Industrial Imager


Includes:

  • Imager
  • AC power supply and battery pack charger (including universal AC adapters)
  • Two rugged lithium ion smart battery packs
  • USB cable
  • Rugged, hard carrying case
  • Adjustable hand strap and neck strap

Given that the fluke ii900 is measure's accustic (Sound level) will it work in a noisy environment? While production lines are running next to it?

Asked by: ACONTR
Yes, the Fluke ii900 Industrial Acoustic Imager will work in noisy environments, but depending on noise level can play a factor in what is being read.
Answered by: FlukeCorp
Date published: 2023-10-03

Can this find Natural Gas leaks?

Asked by: Doug Power Plant Tech
The Fluke ii900 Industrial Acoustic Imager measures sound, which means if the leak has enough volume/sound the Fluke ii900 Industrial Acoustic Imager can pick it up. We also have a resource that may provide additional information: https://dam-assets.fluke.com/s3fs-public/6013561a-en-ii900-case-study-localize-leaks-ngsi-w.pdf?Py6cafJVLlmeUAUFTNsOXOY2heECqKlp
Answered by: FlukeCorp
Date published: 2023-11-20

What is the reading capability like for Steam Leaks? Are there any resources about Steam Leak Detection?

Asked by: Brian MRO
The Fluke ii900 Industrial Acoustic Imager can identify and locate steam, but not quantify the amount.
Answered by: FlukeCorp
Date published: 2023-03-16

Is there an ATEX zone II version?

Asked by: Greg B

Can this find a leak through 2" fiberglass insulation?

Asked by: RickyS
  • y_2024, m_11, d_19, h_8CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_2, bvpage2n
  • co_hasquestionsanswers, tq_13
  • loc_en_US, sid_3747386196020, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 157.03ms
  • QUESTIONS, PRODUCT
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 26.87ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.