Fluke 301A

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 55.51ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • 301A 1500x1000
  • 301A 1500x1000 02
  • 301A 1500x1000 03
  • 301A 1500x1000 04

Key features

  • The body weighs only 132g and is 16mm thick, which is light and portable and can be fitted into a pocket
  • The slim and thin jaw of only 10mm can easily clamp onto tightly packed wires
  • 400A AC range, 0.01A high resolution
  • Tests voltage, resistance and continuity
  • Tests current frequency and voltage frequency
  • Tests capacitance and diodes

Product overview: Fluke 301A

Fluke 301A
The Fluke 301A Clamp Meter has a lightweight and compact body, which allows you to carry it around in your pocket. The slim and thin jaw can easily clamp onto tightly packed wires. The Fluke 301A tests current, voltage, resistance, continuity, frequency (voltage and current), capacitance, and diode, etc.. You can handle more testing needs with it.

Specifications: Fluke 301A

Specifications
Accuracy is specified for 1 year after calibration, with operating temperatures from 18 °C to 28 °C and relative humidity from 0 % to 75 %. Accuracy specifications take the form of:
±([% of Reading] + [Number of Least Significant Digits]).

Models301A/301A+301B301C
AC Current (45 to 400 Hz)Range40.00 A400.0 A60.00 A600.0 A60.00 A600.0 A1000 A
Resolution0.01 A0.1 A0.01 A0.1 A0.01 A0.1 A1 A
Accuracy2 % + 102 % + 52 % + 102 % + 52 % + 102 % + 52 % + 5
AC Voltage (45 to 400 Hz)Range600.0 V600.0 V600.0 V
Resolution0.1 V0.1 V0.1V
Accuracy1.5% + 51.5% + 51.5% + 5
DC VoltageRange600.0 V600.0 V600.0 V
Resolution0.1 V0.1 V0.1 V
Accuracy1% + 51% + 51% + 5
ResistanceRange600.0 Ω
6.000 kΩ
60.00 kΩ
600.0 Ω
6.000 kΩ
60.00 kΩ
600.0 Ω
6.000 kΩ
60.00 kΩ
Accuracy1% + 51% + 51% + 5
Voltage FrequencyRange9.999 Hz
99.99 Hz
999.9 Hz
9.999 kHz
99.99 kHz
9.999 Hz
99.99 Hz
999.9 Hz
9.999 kHz
99.99 kHz
9.999 Hz
99.99 Hz
999.9 Hz
9.999 kHz
99.99 kHz
Accuracy0.1% + 30.1% + 30.1% + 3
Current FrequencyRange45.0 to 400.0 Hz45.0 to 400.0 Hz45.0 to 400.0 Hz
Accuracy0.1% + 30.1% + 30.1% + 3
CapacitanceRange9.999 uF99.99 uF 999.9 uF9.999 uF99.99 uF 999.9 uF9.999 uF99.99 uF 999.9 uF
Accuracy2 % + 55% + 52 % + 55% + 52 % + 55% + 5
DiodeRange3.000 V3.000 V3.000 V
Accuracy10%10%10%
T-rms Value--
Continuity
Hold
Backlight-
Safety ratingCAT III 300VCAT III 300VCAT III 300V
Weight132 g132 g132 g
Size190 mm x 52 mm x 16 mm190 mm x 52 mm x 16 mm190 mm x 52 mm x 16 mm
Jaw Opening34 mm34 mm34 mm
Clamp Arm Size10 mm X 10 mm10 mm X 10 mm10 mm X 10 mm
Battery(2) AAA Batteries(2) AAA Batteries(2) AAA Batteries
Warranty1 year1 year1 year
General Specifications
Maximum Voltage between any Terminal and Earth Ground300 V
Maximum Differential Voltage between V/Ω and COM Terminals600 V
Display (LCD)6000 counts, updates 3 times per second
Battery Type2 AAA, IEC LR03
Battery Life500 hours minimum
Auto Power Off Time20 minutes
TemperatureOperating: -10 °C to 50 °C;
Storage: -30 °C to 60 °C
Relative HumidityOperating Humidity: Non condensing (<10°C); ≤ 90 % RH at 10 °C to 30 °C; ≤ 75 % RH at 30 °C to 40 °C; ≤ 45 % RH at 40 °C to 50 °C;
AltitudeOperating: 2000 m; Storage: 12000 m
Temperature Coefficient0.1 x (specified accuracy) /°C (<18 °C or>28 °C)
Dimensions (H x W x L)190 mm x 52 mm x 16 mm
Weight132 g
Jaw Opening34 mm
Ingress Protection RatingIP30
SafetyIEC 61010--1, IEC61010-2-032 CAT III 300 V, Pollution Degree 2
Electromagnetic EnvironmentIEC 61326--1: Portable

Models: Fluke 301A

Fluke 301A

Models: Fluke 301A Clamp Meter


Buy it

Fluke 301A

  • Fluke 301A Clamp Meter
  • (2) AAA batteries

Fluke 301A+

  • Fluke 301A Clamp Meter
  • TL75 test lead
  • (2) AAA batteries

Note: Fluke 301A is the standard model without test leads.
Fluke 301A+ includes Fluke301A and a TL75 teat lead.

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 67.35ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 22.33ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.