Fluke 709 Precision mA Loop Calibrator

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 173.76ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • Fluke 709 Precision Loop Calibrator
  • Fluke 709 Precision Loop Calibrator

Key features

  • mA precision loop calibrator with best-in-class accuracy at 0.01% reading
  • Provides intuitive user interface with quick-set rotary encoder knob for fast setup
  • Includes built in selectable 250 Ω resistor for HART communication
  • Features 24 V DC loop power with mA Measure Mode (-25% to 125%)
  • Requires only simple two wire connection for all measurements

Product overview: Fluke 709 Precision mA Loop Calibrator

The Fluke 709 mA loop calibrator is designed to reduce the time it takes to measure or source voltage or current and power up a loop and still produce high-quality results. The Fluke 709 is built around a user friendly interface with a quick-set rotary encoder knob and best in class accuracy at 0.01% of reading. It features a protective holster that fits easily in a technician's hand and a large backlit display that is easy to read, even in dark, cramped work areas. So it's a great choice anywhere you need a compact, rich featured precision loop calibrator.

Other useful features:

  • Provides resolution of 1 µA on mA ranges and 1 mV on voltage ranges
  • Features a compact rugged design and runs on 6 standard AAA batteries
  • Provides Auto Shutdown to conserve battery life (adjustable up to 30 minutes)
  • Offers variable step and ramp time in seconds
  • Provides adjustable span selection (0 to 20 mA or 4 to 20 mA)
  • Includes valve test functionality (simulates defined mA values with % keys)

Related blog posts:

Process tools best practices

What's in the box:

  • Fluke 709 Precision Loop Calibrator
  • (1 set) AC175 Alligator Clip
  • (1 pair) TL75 Test Leads
  • Soft Case
  • (6) AAA Batteries (installed)
  • NIST- traceable calibration report and data
  • Quick Reference Guide
  • 3-year warranty

Specifications: Fluke 709 Precision mA Loop Calibrator

Detailed Specifications
FunctionsmA source, mA simulate, mA read, mA read/loop power, and volts read.
RangesmA (0 to 24 mA) and Volts (0 to 30 V DC)
Resolution1 µA on mA ranges and 1 mV on voltage range
Accuracy0.01% ± 2 counts, all ranges (@23° ± 5°C)
Operating temperature range-10°C to 55°C  (14°F to 131°F)
Humidity range10 to 95% non-condensing
Stability20 ppm of F.S. /°C from -10°C to 18°C and 28°C to 55°C
Display128 x 64 pixels, LCD graphic w/backlight, .34 high digits
Power6 AAA alkaline
Battery life40 hours typical
Loop compliance voltage24 V DC @ 20 mA
Over-voltage protection240 V AC
Overload current protection28 mA DC
EMCEN61326 Annex A (Portable Instruments)
Dimensions (L x W x D)15 x 9 x 3 cm (6 x 3.6 x 1.3 in)
Weight0.3 kg (9.5 oz)
Included accessoriesNIST traceable calibration certificate with data, batteries, test leads, and manual
WarrantyOne year

Models: Fluke 709 Precision mA Loop Calibrator

Fluke 709
Fluke 709 Precision Loop Calibrator

Buy it

Includes:

  • AC175 Alligator Clip Set
  • TL75 Test Leads
  • Soft Case
  • Six AAA Batteries (Installed)
  • Product Manual CD-ROM
  • Quick Reference Guide
  • Safety Information

Hi, does the 709 have enough power for connecting directly to a smart valve positioner ( without using a external power supply) - for stroke testing - say a fisher DVC .

Asked by: matty
The Fluke 709, 709H, and 710 Precision mA Loop Calibrators, can stroke most valves. Maximum load impedance for the valve must be 1200 ohms or less to drive a 4-20 mA signal.
Answered by: FlukeCorp
Date published: 2023-06-21
  • y_2024, m_12, d_3, h_7CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_1
  • loc_en_US, sid_3840953090100, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 23.19ms
  • QUESTIONS, PRODUCT
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 23.26ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.