Fluke TiS45 Infrared Camera
Key features
- Manual focus infrared camera with 160x120 resolution (19,200 pixels)
- Captures optimal images from as close as 0.15m (6in)
- Helps you find problems fast with exclusive IR-Fusion® AutoBlend and PIP modes
- Provides a D:S of 257:1
- Offers a temperature measurement range from -20 °C to 350 °C (–4 °F to 662 °F)
- Displays images on a 3.5 inch, 320x240 LCD
- Captures visible light images with built-in 5 megapixel industrial performance digital camera
- Includes a smart battery system that allows you to easily monitor your battery charge level with five-segment LED display
- Allows real-time communication by email from your smart phone with Fluke Connect®*
- Stores thousands of images—4 GB internal memory and optional 4 GB micro SD card
Product overview: Fluke TiS45 Infrared Camera
Fluke TiS45 Infrared Camera delivers the flexibility of manual focus to capture the best possible image of your target
Electricians and technicians can increase their inspection and repair speed with the TiS45 Infrared Camera. Its 160x120 resolution and manual focus deliver the versatility you need for multiple industrial applications. And it is built rugged so you can take it anywhere. With five presets of IR-Fusion® AutoBlend™ you can blend a visible light image with an infrared image at five different levels to more easily locate problems. Likewise, picture-in-picture mode lets you maintain a frame of reference by placing an infrared window within the digital image to highlight the point of interest. With a distance to spot (D:S) ratio of 257:1 you can capture those images from a longer distance away.
With 4 GB internal memory and 4 GB more with an optional micro SD card, you can store thousands of images on the TiS45, making it quick and easy to document problems. And with the lithium ion smart battery with the five-segment LED charge level display, you'll always know how much power you have left.
Collaborate from the field with Fluke Connect® connectivity
Because the TiS45 is Fluke Connect-enabled you can share images in real-time¹ across teams and save time by creating and emailing reports from the jobsite. Capture multiple measurements and save them to the cloud with WiFi upload and free storage for up to 5GB with Fluke Cloud™.
Get more out of your images with Fluke Connect® SmartView® IR Analysis Reporting Software
You can use Fluke Connect SmartView software to analyze images from the TiS45 with graphical tools to quantify the severity of problems. you're done analyzing you can easily generate a professional report complete with thermal images with the easy-to-follow report wizard to guide you step by step.
¹ Within your provider's wireless service area; Fluke Connect is not available in all countries
Specifications: Fluke TiS45 Infrared Camera
Key Features | |
IFOV (spatial resolution) | 3.9 mRad |
Detector resolution | 160x120 |
Field of view | 35.7 ° x 26.8 ° |
Distance to spot | 257:1 |
Wireless connectivity | Yes |
Fluke Connect® app compatible | Yes (where available) |
IR-Fusion® Technology | |
AutoBlend™ mode | 5 presets (0%, 25%, 50%, 75%, 100%) |
Picture-In-Picture (PIP) | 5 presets (0%, 25%, 50%, 75%, 100%) |
Focus system | Manual focus, Minimum focus distance, 0.15 m (6 in) |
Ruggedized display | 3.5 inch (landscape) 320x240 LCD |
Rugged, ergonomic design for one-handed use | Yes |
Thermal sensitivity (NETD) | ≤0.09 °C at 30 °C target temp (90 mK) |
Temperature measurement range (not calibrated below -10 °C) | -20 °C to +350 °C (–4 °F to 662 °F) |
Level and span | Smooth auto and manual scaling |
Fast auto toggle between manual and auto modes | Yes |
Fast auto-rescale in manual mode | Yes |
Minimum span (manual mode) | 2.5 °C |
Minimum span (auto mode) | 5 °C |
Built-in digital camera (visible light) | 5 MP |
Frame rate | 9 Hz or 30 Hz |
Laser pointer | - |
Data storage and Image Capture | |
Extensive SD memory system | Internal 4 GB memory and 4 GB removable micro SD card |
Image capture, review, save mechanism | One-handed image capture, review, and save capability |
Image file formats | Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2); No analysis software required for non-radiometric (.bmp, .jpg) files |
Instant Upload | Instantly upload captured images to Fluke Connect server with the use of a WiFi connection |
Memory review | Thumbnail review |
Software | SmartView® software - full analysis and reporting software and Fluke Connect® (where available) |
Export file formats with SmartView® software | BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF |
Voice annotation | - |
IR-PhotoNotes™ | - |
Standard video recording | - |
Radiometric video recording | - |
Video file formats | - |
Streaming video (remote display) | - |
Battery | |
Batteries (field-replaceable, rechargeable) | One lithium ion smart battery pack with five-segment LED display to show charge level |
Battery life | Four+ hours |
Battery charge time | 2.5 hours to full charge |
Battery charging system | In-imager charging (optional external charger sold separately) |
AC operation | AC operation with included power supply (100 V AC to 240 V AC, 50/60 Hz) |
Temperature Measurement | |
Accuracy | ±2 °C or 2% (at 25 °C nominal, whichever is greater) |
On-screen emissivity correction | Yes (both value and table) |
On-screen reflected background temperature compensation | Yes |
On-screen transmission correction | Yes |
Color Palettes | |
Standard palettes | 7: Ironbow, Blue-Red, High-Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted |
Ultra Contrast™ palettes | - |
General Specifications | |
Color alarms (temperature alarms) | High temperature, low temperature |
Infrared spectral band | 7.5 μm to 14 μm |
Operating temperature | -10 °C to +50 °C (14 °F to 122 °F) |
Storage temperature | -20 °C to +50 °C (-4 °F to 122 °F) |
Relative humidity | 10% to 95%, non-condensing |
Center-point temperature measurement | - |
Spot temperature | Yes |
User-definable spot markers | 1 |
Center box | - |
Safety standards | EN 61010-1: CAT none, pollution degree 2, EN 60825-1: Class 2, EN 60529, EN 62133 (lithium battery) |
Electromagnetic compatibility | EN 61326-1:2006, EN 55011: Class A, EN 61000-4-2, EN 61000-4-3 |
C Tick | IEC/EN 61326-1 |
US FCC | EN61326-1; FCC Part 5, EN 55011: Class A, EN 61000-4-2, EN 61000-4-3 |
Vibration and shock | 2G, IEC 68-2-6 and 25G, IEC 68-2-29 |
Drop | Engineered to withstand 2 m (6.5 ft) drop |
Size (H x W x L) | 26.7 x 10.1 x 14.5 cm (10.5 x 4.0 x 5.7 in) |
Weight (battery included) | Fixed focus .72 kg (1.6 lb), Manual focus .77 kg (1.7 lb) |
Enclosure rating | IP54 (protected against dust, limited ingress; protection against water spray from all directions) |
Warranty | Two-years (standard), extended warranties are available |
Recommended calibration cycle | Two-years (assumes normal operation and normal aging) |
Supported languages | Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish |
Models: Fluke TiS45 Infrared Camera
UPC#: 0 95969 79886 0
- Thermal imager 30 Hz
- AC charger/power supply with mains adapters for battery charging and AC operation
- One rugged lithium ion smart battery
- USB cable
- Adjustable hand strap
- Rugged, hard carrying case
- Soft transport bag
- Statement of factory calibration
- Quick start guide
- Safety sheet
UPC#: 0 95969 79885 3
- Thermal imager 9 Hz
- AC charger/power supply with mains adapters for battery charging and AC operation
- One rugged lithium ion smart battery
- USB cable
- Adjustable hand strap
- Rugged, hard carrying case
- Soft transport bag
- Statement of factory calibration
- Quick start guide
- Safety sheet
Manuals + resources: Fluke TiS45 Infrared Camera
- TiS10, TiS20, TiS40, TiS45, TIS50, TiS60, TiS65, TiS75 | Users manual
- TiS10, TiS20, TiS40, TiS45, TIS50, TiS60, TiS65, TiS75 | Users manual supplement
- TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65 | Quick reference guide
- TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65, TiS75 | Safety sheet
- TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65, TiS75 | Statement of memory volatility