Fluke Calibration 6109A / 7109A Portable Calibration Baths

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 196.64ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • 6109A 7109A 5
  • 6109A 7109A 4
  • 6109A 7109A 2
  • 6109A 7109A 3

Key features

  • Calibrate up to four tri-clamp sanitary sensors per batch with ± 0.1 °C temperature display accuracy.
  • Covers a wide temperature range: 6109A: 35 °C to 250 °C
  • 7109A: -25 °C to 140 °C.
  • Stainless steel casing that withstands harsh cleaning solutions; it's easy to transport and maintain.

Product overview: Fluke Calibration 6109A / 7109A Portable Calibration Baths

Four times more calibration throughput with twice the accuracy of Micro-Baths and dry-block calibrators


Process manufacturing plants for pharmaceuticals, biotechnology, and food production utilize many sanitary temperature sensors that require regular calibration. Production must stop while the calibrations are taking place. Therefore, more calibration throughput means less plant downtime. And in businesses where even a few tenths of a degree Celsius can cost thousands of dollars in ruined product, temperature accuracy is crucial to maintaining quality.

The Fluke Calibration 6109A and 7109A Portable Calibration Baths let process industry professionals calibrate four times more sanitary sensors per batch in less time and with twice the accuracy of other baths in this class. Up to four tri-clamp sanitary sensors fit easily into these baths for calibration at ± 0.1 °C temperature display accuracy. Throughput is even higher for sanitary RTDs with small or no flanges.

Two bath models cover a wide temperature range: 35 °C to 250 °C for the 6109A and -25 °C to 140 °C for the 7109A. Each model offers a “-P” version that includes process electronics for connecting an external reference probe.

Professionals working in clean process industries, including facilities managers, production engineers and calibration technicians, prefer these baths for a variety of reasons.

Facilities managers who need to meet U.S. FDA and ISO clean room standards like the baths’ stainless steel casing that stands up to harsh cleaning solutions. They depend on the 6109A and 7109A to help maintain the accuracy of the plant’s temperature sensors, thus reducing the possibility of an expensive product batch loss.

Production engineers also appreciate the baths’ accuracy, which helps them control sensor out-of-tolerance conditions. Moreover, they prefer to use a bath designed specifically for clean room calibration throughput. No more need to make do with equipment designed for some other application.

Calibration technicians who perform calibrations on platforms, in crawl spaces, and other hard-to-reach parts of the plant enjoy the portability and clean room compatibility (i.e. easy to sanitize, don’t harbor bacteria) of these baths.

Global Fluke Calibration service and support ensure that your 6109A and 7109A baths will give you years of service that you can trust.

Calibrate more sanitary sensors at a time – with confidence


The 6109A and 7109A baths calibrate most temperature sensor applications used in clean process manufacturing, including pharmaceutical bioreactors (-10 C to 100 °C), chemical reactors (200 °C), steam-in-place process (122 °C to 140 °C), autoclave sterilization (120 °C to 135 °C), food storage freezers (-25 °C), and food processing (0 °C to 220 °C).

A large tank volume (112 mm square tank opening x 154 mm depth) lets you immerse up to four sanitary sensors at the same time. Calibrate a batch of odd shaped sensors of varying lengths and diameters, and still have room for a reference thermometer. Fast heating and cooling times let you get the job done without spending a lot of time waiting for the bath to come to temperature and stabilize. Increase your sanitary sensor calibration throughput and decrease expensive production downtime.

Excellent system display accuracy of ± 0.1 °C. Accuracy covers all sources of error including calibration uncertainty, stability, uniformity, and repeatability. NVLAP accredited calibration is included standard. Fluke Calibration’s high metrological standards and conservative specifications mean you can have confidence in the measurements you make with the 6109A and 7109A Portable Calibration Baths.

Take these portable baths almost anywhere, including the clean room


The 6109A weighs 16 kilograms (35 pounds) and the 7109A weighs 20 kilograms (44 pounds). They each feature a fixed, non-rotating bail handle, enabling most people to carry a bath with one hand. Single-handed carrying comes in handy when the job includes walking up and down stairs, across catwalks, and into other hard-to-reach environments. Two recessed handles on the bottom of each bath also make it easy to move from a shelf to a cart or benchtop. A sealed lid protects against fluid spills while moving the bath.

Stainless steel casing stands up to the harsh chemicals used to sterilize equipment for clean room use. Synthetic materials used for decals, keypads and feet do not harbor bacteria. The keypad is sealed against moisture ingress to protect against damage during cleaning or in non-controlled environments.

Easy to use and maintain


Each bath features a large color display that indicates date and time, bath fluid temperature, setpoint temperature, control indicator when the fluid is at setpoint, and heating status. A ready indicator changes color from amber to green, giving you 360-degree visual indication when the bath fluid has reached its setpoint temperature and is ready for you to start making measurements.

A hot warning indicator lights up if the fluid temperature reaches above 60 °C, warning the operator that the bath fluid and tank area are hot and should not be touched.

An adjustable probe fixture holds up to four tri-clamp sensors securely inside the tank opening during calibration. An optional single probe clamp kit holds a reference probe.

Fluid spills create mess and potential safety hazards. The 6109A and 7109A include an overflow tube that directs excess bath fluid into an optional overflow container. A drain tube makes it easy to remove bath fluid for replacement or transport.

I own a Fluke Calibration Micro-Bath. Why do I need a 6109A or 7109A bath?


If you already own a Fluke Calibration Micro-Bath or dry-block calibrator, thank you for being a customer! We hope you are enjoying the portability and stability of these popular products.

However, there are a few reasons why you should consider adding a 6109A or 7109A bath:

Errors of just a few tenths of a degree Celsius can cause expensive losses in ruined product. The 6109A and 7109A baths are twice as accurate as a Micro-Bath, helping you to reduce this risk. The 6109A and 7109A have four times the calibration throughput of a Micro-Bath, which can only calibrate a single tri-clamp sensor at a time. They're made with materials that don't harbor bacteria. Their stainless steel panels and tank are easy to clean and rust resistant--perfect for clean room use. We hope you will continue to use your Fluke Calibration Micro-Bath for many years to come. The 6109A or 7109A baths will also serve you well if you need the throughput, accuracy, and clean room readiness that they provide.

Backed by global Fluke support and service


The 6109A and 7109A are designed to meet demanding Fluke Calibration metrology specifications, so you can trust that they will perform the way we say they will. Need assistance? We offer world-class support both before and after the sale, via online chat, email, telephone and through our service organizations. Rest easy knowing the value of your investment will be preserved now and into the future.

 

Specifications: Fluke Calibration 6109A / 7109A Portable Calibration Baths

General specifications
SizeHeight: 382 mm (15 in)
Width: 242 mm (9.5 in)
Depth: 400 mm (15.7 in)
Weight6109A: 16 kg (35 lb)
7109A: 20 kg (44 lb)
Fluid volume2.5 liters (0.66 gallons)
Fluid working area75 mm x 75 mm (3 in x 3 in)
Maximum fluid depth154 mm (6.1 in)
Factory calibrationTraceable NVLAP-accredited calibration included
Temperature specifications
The temperature specifications describe the Absolute Instrumental Uncertainty at 95 % level of confidence (coverage factor k = 2) within one year from calibration. The specifications include environmental temperature effects from 13 °C to 33 °C.
 6109A7109A
Range (at 25 °C ambient temperature)35 °C to 250 °C–25 °C to 140 °C (–15 °C cover off)
Accuracy (maximum permissible error)0.1 °C0.1 °C
Display resolution0.01 °, 0.001°0.01 °, 0.001°
Stability0.015 °C0.01 °C
Typical uniformity0.03 °C up to 200 °C
0.04 °C above 200 °C
0.02 °C
Repeatability0.04 °C0.04 °C
Typical heating time35 °C to 100 °C: 25 minutes
100 °C to 250 °C: 45 minutes
–25 °C to 25 °C: 35 minutes
25 °C to 140 °C: 55 minutes
Typical cooling time250 °C to 100 °C: 35 minutes
100 °C to 35 °C: 55 minutes
140 °C to 25 °C: 45 minutes
25 °C to –25 °C: 75 minutes
Typical settling time15 minutes10 minutes
Process Input Module specifications (-P models)
The Input Module specifications describe the Absolute Instrumental Uncertainty at 95 % level of confidence (coverage factor k = 2) within one year from calibration. The specifications include calibration uncertainty, linearity, repeatability, resolution, stability, and environmental temperature effects from 13 °C to 33 °C.
FunctionRangeAccuracy (Maximum Permissible Error)
Reference input resistance0 Ω to 42 Ω
42 Ω to 400 Ω
0.0025 Ω
0.006 %
Reference input temperature-25 °C to 250 °C0.007 % + 0.015 °C
Resistance sensing current1 mA8 %
DUT 4-wire resistance0 Ω to 31 Ω
31 Ω to 400 Ω
0.0025 Ω
0.008%
DUT 3-wire resistance accuracy0 Ω to 400 Ω0.12 Ω
Thermocouple mV-10 mV to 100 mV0.025 % + 0.01 mV
Reference junction temperature0 °C to 40 °C0.35 °C
Thermocouple temperature-25 °C to 250 °CJ: 0.44 °C
E: 0.44 °C
L: 0.42 °C
K: 0.49 °C
N: 0.57 °C
U: 0.48 °C
T: 0.53 °C
M: 0.48 °C
0 °C to 250 °CR: 1.92 °C
D: 1.12 °C
S: 1.88 °C
G/W: 3.34 °C
C: 0.84 °C
mA range0 mA to 22 mA0.02 % + 0.002 mA
Loop power24 V dc± 6 V

Models: Fluke Calibration 6109A / 7109A Portable Calibration Baths

6109A
6109A
Portable Calibration Bath, 35 °C to 250 °C

Buy it
6109A-P
6109A-P
Portable Calibration with Process Electronics, 35 °C to 250 °C

Buy it
7109A
7109A
Portable Calibration Bath, -25 °C to 140 °C

Buy it
7109A-P
7109A-P
Portable Calibration Bath with Process Electronics, -25 °C to 140 °C

Buy it

Can this product be connected by wifi to a network?

Asked by: Anonymous
  • y_2024, m_11, d_22, h_7CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestions, tq_1
  • loc_en_US, sid_4651128356916, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 116.9ms
  • QUESTIONS, PRODUCT
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 25.76ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.