Fluke 115 Field Technicians Digital Multimeter

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 72.68ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • Fluke 115 Technician’s Digital Multimeter
  • Fluke 115 What’s In The Box
  • 115 DMM measures ac and dc voltage current and more
  • Fluke 115 DMM offers basic electrical and electronic tests

Key features

  • Compact True-rms digital multimeter for field service
  • Includes: meter, holster, 4 mm PVC-Insulated test lead
  • Easy one-handed operation of the meter
  • Min/Max/Average to record signal fluctuations
In stock
S$444.72
9% GST Included
Genuine Fluke Product
Free shipping for cart size over $50
Parcel will be shipped out within 3 working days. If there are delays due to unforeseen circumstances, we will keep you updated.

Product overview: Fluke 115 Field Technicians Digital Multimeter

Compact true-rms meter for field service technicians

The Fluke 115 field technician’s digital multimeter measures True-rms voltage and current with plus resistance, continuity, frequency, and capacitance to meet the needs of a wide variety of field service technicians.

The 115 digital multimeter offers the users one-handed operation and a backlit display. The large, easy-to-read digits offer a 6000-count resolution. The 115 provides Min/Max/Average with elapsed time to record signal fluctuations. It also measures:

  • AC and DC voltage to 600V,
  • AC and DC current to 10 A (20 A overload for 30-seconds max).

2019 Best Multimeters, Top Pick – GeekWrapped.com

For a complete comparison of specifications, please visit our selection guide for digital multimeters.

 
 Fluke 115 Field Technicians Digital MultimeterFluke 117 Electrician's MultimeterFluke 177 True-RMS Digital MultimeterFluke 233 Remote Display Digital MultimeterFluke 3000 FC Series Wireless Multimeter
CAT ratingCAT III 600 VCAT III 600 VCAT III 1000 V
CAT IV 600 V
CAT III 1000 V
CAT IV 600 V
CAT III 1000 V
CAT IV 600 V
True-rms readings
Voltage AC/DC600 V600 V1000 V1000 V1000 V
Current AC/DC10 A10 A10 A10 A400 mA
Resistance40 MΩ40 MΩ50 MΩ40 MΩ50 MΩ
Capacitance9,999 μF9,999 μF9,999 μF9,999 μF9,999 μF
Temperature-40 °C to 400 °F-40 °C to 400 °F-40 °C to 400 °F-40 °C to 400 °Fwith t3000 FC
Additional
measurement
capabilities
Continuity/diode testContinuity/diode test,
frequency, non-contact
voltage detection
Continuity/diode test,
frequency,
low input impedance
Continuity/diode test,
frequency
Frequency,
continuity/diode test.
Able to connect to
three 3000 FC
modules.

What's in the box:

  • Digital multimeter
  • Holster
  • Installed 9V battery
  • 4 mm PVC-Insulated test lead
  • Quick Reference Guide

Specifications: Fluke 115 Field Technicians Digital Multimeter

Specifications
Accuracy Specifications
DC millivoltsRange/resolution600.0 mV / 0.1 mV
Accuracy± ([% of reading] + [counts]): 0.5% + 2
DC voltsRange/resolution6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy± ([% of reading] + [counts]): 0.5% + 2
AC millivolts1 True RMSRange/resolution600.0 mV / 0.1 mV
Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
AC volts1 True RMSRange/resolution6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
ContinuityRange/resolution600 Ω / 1 Ω
AccuracyBeeper on < 20 Ω, off > 250 Ω detects opens or shorts of
500 μs or longer.
OhmsRange/resolution600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ
Accuracy0.9% + 1
Range/resolution40.00 MΩ / 0.01 MΩ
Accuracy5% + 2
Diode testRange/resolution2.00 V / 0.001 V
Accuracy0.9% + 2
CapacitanceRange/resolution1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μF
Accuracy1.9% + 2
Range/resolution> 1000 μF
Accuracy5% + 20%
Lo-Z capacitanceRange1 nF to 500 μF
Accuracy10% + 2 typical
AC amps True RMS
(45 Hz to 500Hz)
Range/resolution6.000 A / 0.001 A
10.00 A / 0.01 A
Accuracy1.5% + 3
20 A overload for 30-seconds max
DC ampsRange/resolution6.000 A / 0.001 A
10.00 A / 0.01 A
Accuracy1.0% + 3
20 A overload for 30-seconds max
Hz (V or A input)2Range/resolution99.99 Hz / 0.01 Hz
999.9 Hz / 0.01 Hz
9.999 kHz / 0.001 kHz
50.00 kHz / 0.01 kHz
Accuracy0.1% + 2
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
2. Frequency is AC coupled, 5Hz to 30 kHz for AC voltage.
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
2. Temperature Range/Resolution: -40℉ to 752℉ / 0.2℉.
General Specifications
Maximum voltage between any terminal and earth ground600 V
SafetyIEC 61010-1: Pollution Degree 2
IEC 61010-2-033: CAT III 600V
DisplayDigital: 6,000 counts, updates 4 per second
Bar graph33 segments, updates 32 per second
Operating temperature-10℃ to + 50℃
Storage temperature-40℃ to + 60℃
Battery type9 volt Alkaline, IEC 6LR61
Battery life400 hours typical, without backlight
Size167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
Weight550 g
Warranty3 years

Models: Fluke 115 Field Technicians Digital Multimeter

FLUKE-115
Fluke 115 Digital Multimeter

Buy it

Includes:

  • Holster
  • Installed 9V battery
  • 4 mm PVC-Insulated test lead
  • User manual
FLUKE-115/EM ESP
Fluke 115 Digital Multimeter

Buy it

Includes:

  • Holster
  • Installed 9V battery
  • 4 mm silicone test lead set
  • User manual
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 134.98ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 128.05ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.