Fluke 377 FC Non-Contact Voltage True-rms AC/DC Clamp Meter with iFlex

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 205.29ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • Fluke 377 FC measures voltage and current with the clamp jaw
  • Fluke 377 FC uses FieldSense technology for faster, safer testing.
  • Fluke 377 FC includes clamp, leads, grounding clip, iFlex high-current probe, magnetic hanging strap, premium carrying case.
  • Fluke 377 FC sends readings to your smart phone via Fluke Connect software
  • Video Player is loading.
    Current Time 0:00
    Duration 0:46
    Loaded: 0%
    Stream Type LIVE
    Remaining Time 0:46
     
    1x
      • Chapters
      • descriptions off, selected
      • en (Main), selected
    • Video Player is loading.
      Current Time 0:00
      Duration 1:09
      Loaded: 0%
      Stream Type LIVE
      Remaining Time 1:09
       
      1x
        • Chapters
        • descriptions off, selected
        • en (Main), selected
      1. Fluke 377 FC measures voltage and current with the clamp jaw
      2. Fluke 377 FC uses FieldSense technology for faster, safer testing.
      3. Fluke 377 FC includes clamp, leads, grounding clip, iFlex high-current probe, magnetic hanging strap, premium carrying case.
      4. Fluke 377 FC sends readings to your smart phone via Fluke Connect software
      5. Fluke 377/378 FC Non-Contact Voltage True-rms AC/DC Clamp Meter with iFlex - Video
      6. The Fluke 377 FC and 378 FC Clamp Meters overview

      Key features

      • Measure voltage and current with your clamp jaw
      • Faster, safer testing - all without touching a live wire - using FieldSense™ technology
      • Complete 3-phase voltage and current tests in 3 quick steps
      In stock
      S$1,437.71
      9% GST Included
      Genuine Fluke Product
      Free shipping for cart size over $50
      Parcel will be shipped out within 3 working days. If there are delays due to unforeseen circumstances, we will keep you updated.

      Product overview: Fluke 377 FC Non-Contact Voltage True-rms AC/DC Clamp Meter with iFlex

      Voltage and current measurements with FieldSense™ technology

      The Fluke 377 FC true-rms clamp meter uses FieldSense™ technology to make testing faster and safer, all without contacting a live conductor. You get accurate voltage and current measurements through the clamp jaw. Simply clip the black test lead to any electrical ground, put the clamp jaw around the conductor and see reliable, accurate voltage and current values on the display.

      Measure extremely high current with iFlex® probe

      Use the included iFlex flexible current probe to measure ac current as high as 2500 A. The iFlex probe provides access to large conductors in tight spaces.

      Complete 3-phase measurements in quick, easy steps

      • Complete 3-phase voltage and current tests in 3 easy steps
      • Full set of phase-to-ground and phase-to-phase values calculated and shown on the meter
      • Values are also displayed on your smart phone and saved to the cloud via Fluke Connect software
      • Phase rotation auto-calculated and shown on the Fluke Connect software
      • No more hand-written notes or complicated math.

      Easy to see, easy to use with included tools

      Your job will get easier when you use the 377 FC clamp meter. The display turns green when a stable FieldSense measurement is detected. Visual Continuity also provides a bright green screen for easy detection of continuity in noisy work areas.

      Record, analyze, share results with Fluke Connect® software

      With Fluke Connect software you can remotely log, trend and monitor measurements to pinpoint intermittent faults. Fluke Connect also allows you to gather data as the basis for a preventive maintenance program.

       

      What's in the box:

      The 377 FC current clamp includes:

      • 377 FC Non-Contact Voltage True-rms Clamp Meter
      • iFlex flexible current probe (18 inches; 48 cm)
      • TL224 silicone insulated test leads
      • TP175 adjustable length test probes
      • AC285 grounding clip (black, quantity one)
      • TPAK magnetic hanging kit, with 9 inch (23 cm) hanging strap
      • Premium Carrying case
      • Quick reference guide

      Specifications: Fluke 377 FC Non-Contact Voltage True-rms AC/DC Clamp Meter with iFlex

      General specifications
      General Maximum Voltage between any Terminal and Earth Ground1000 V
      BatteryType2 AA IEC LR6 alkaline
      Life200 hour
      DisplayDual readout
      Automatic Power Off20 minutes
      Electrical
      AC Current: Jaw
      Range999.9 A
      Resolution0.1 A
      Accuracy2 % ±5 digits (45 Hz to 66 Hz)
      Crest Factor (50/60 Hz)3 @ 500 A
      2.5 @ 600 A
      1.42 @ 1000 A
      Add 2 % for C.F. >2
      AC Current: Flexible Current Probe
      Range2500 A
      Resolution1 A (≤2500 A) 0.1 A (≤999.9 A)
      Accuracy3 % ±5 digits (5 Hz to 500 Hz)
      Crest Factor (50/60Hz)3.0 at 1100 A
      2.5 at 1400 A
      1.42 at 2500 A
      Add 2 % for C.F. >2
      Position Sensitivity
      Flexible current probeDistance from Optimumi2500-10 Flexi2500-18 FlexError
      A0.5 in (12.7 mm)1.4 in (35.6 mm)± 0.5 %
      B0.8 in (20.3 mm)2.0 in (50.8 mm)± 1.0 %
      C1.4 in (35.6 mm)2.5 in (63.5 mm)± 2.0 %
      Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
      DC Current
      Range999.9 A
      Resolution0.1 A
      Accuracy2 % ±5 digits1
      [1]When using the ZERO function to compensate for offsets
      AC Voltage: Field Sense
      Range1000 V
      Resolution1 V (≤1000V)
      Accuracy≤4/0 AWG3 % ±5 digits (45 Hz to 66 Hz)
      ≥4/0 AWG5 % ±5 digits (45 Hz to 66 Hz)
      Position wire as close as possible to jaw opening (see illustration).
      AC Voltage: Test Leads
      Range600.0 V 1000 V
      Resolution0.1 V (≤600.0 V)
      1 V (≤1000 V)
      Accuracy1 % ±5 digits (20 Hz to 500 Hz)
      DC Voltage
      Range600.0 V
      1000 V
      Resolution0.1 V (≤600.0 V)
      1 V (≤1000 V)
      Accuracy1 % ±10 digits
      mV dc
      Range500.0 mV
      Resolution0.1 mV
      Accuracy1 % ±5 digits
      Amps Frequency: Jaw
      Range45 Hz to 66 Hz
      Resolution0.1 Hz
      Accuracy0.5 % ±5 digits
      Trigger Level5 Hz to 10 Hz, ≥10 A
      10 Hz to 100 Hz, ≥ 5 A
      100 Hz to 500 Hz, ≥ 10 A
      Amps Frequency: Flexible Current Probe
      Range5.0 Hz to 500.0 Hz
      Resolution0.1 Hz
      Accuracy0.5 % ±5 digits
      Trigger Level5 Hz to 20 Hz, ≥25 A
      20 Hz to 100 Hz, ≥20 A
      100 Hz to 500 Hz,≥25 A
      Resistance
      Range60.00 kΩ
      6000 Ω
      600.0 Ω
      Resolution0.1 Ω (≤600.0 Ω)
      1 Ω (≤6000 Ω)
      10 Ω (≤60.00 kΩ)
      Accuracy1 % ±5 digits
      Capacitance
      Range1000 μF
      Resolution0.1 μF (≤100.0 μF)
      1 μF (≤1000 μF)
      Accuracy1 % ±4 digits
      Mechanical
      Size (L x W x H)274 mm x 86 mm x 47 mm
      Weight (with Batteries)463 g
      Jaw Opening34 mm
      Flexible Current Probe Diameter7.5 mm
      Flexible Current Probe Cable Length (head to electronics connector)1.8 m
      Rogowski Coil Length450 mm
      Environmental
      Operating Temperature-10 °C to 50 °C
      Storage Temperature-40 °C to 60 °C
      Operating Humidity (without condensation)Non condensing (<10 °C)
      ≤90 % RH (10 °C to 30 °C)
      ≤75 % RH (30 °C to 40 °C)
      ≤45 % RH (40 °C to 50 °C)
      Temperature CoefficientsAdd 0.1 x specified accuracy for each degree C >28 °C or <18 °C
      Ingress ProtectionIEC 60529: IP30 (jaw closed)
      Operating Altitude2000 m
      Storage Altitude12 000 m
      Electromagnetic Compatibility (EMC)
      InternationalIEC 61326-1: Portable Electromagnetic Environment
      IEC 61326-2-2, CISPR 11: Group 1, Class B
      Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
      Class B: Equipment is suitable for use in domestic establishments and in establishments directly connected to a low voltage power supply network which supplies buildings used for domestic purposes.
      Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.
      Korea (KCC)Class A equipment (Industrial Broadcast & Communications Equipment)
      Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
      USA (FCC)47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
      Safety
      GeneralIEC 61010-1: Pollution degree 2
      MeasurementIEC 61010-2-032: CAT III 1000 V / CAT IV 600 V
      IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V
      Current Clamp for Leakage Current MeasurementsIEC 61557-13: Class 2, ≤30 A/m
      Wireless Radio
      Radio Frequency CertificationFCC ID: T68-FBLE IC:6627A-FBLE
      Frequency Range2405 MHz to 2480 MHz
      Output Power<100 mW
      Radio Frequency DataRadio Frequency Data For Class A Devices
      SIMPLIFIED EU DECLARATION OF CONFORMITY
      Hereby, Fluke declares that the radio equipment contained in this Product is in compliance with Directive 2014/53/EU. The full text of the EU declaration is available at the following internet address: https://dam-assets.fluke.com/s3fs-public/FLK_RED_1aeng0900.pdf.

      Models: Fluke 377 FC Non-Contact Voltage True-rms AC/DC Clamp Meter with iFlex

      FLUKE-377 FC

      FLUKE-377 FC


      Buy it

      Includes:

      • Fluke 377 FC Non-Contact Voltage True-RMS AC/DC Clamp Meter
      • TL224 Test Leads
      • TP175 TwistGuard™ Test Probes
      • AC285 black grounding clip (1 only)
      • i2500-18 iFlex® Flexible Current Probes 18 inch (48 cm)
      • TPAK ToolPak™ Magnetic Meter Hanger
      • Premium carrying case
      • Quick reference guide
      • bvseo_sdk, p_sdk, 3.2.1
      • CLOUD, getContent, 174.93ms
      • QUESTIONS, PRODUCT
      • bvseo-msg: HTTP status code of 404 was returned;
      • bvseo_sdk, p_sdk, 3.2.1
      • CLOUD, getReviews, 23.6ms
      • REVIEWS, PRODUCT
      • bvseo-msg: HTTP status code of 404 was returned;
      Please enable cookies to view product reviews.