Fluke 106 Digital Multimeter/i400E Clamp Kit

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 162.75ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • Fluke 106 Digital Multimeter/i400E Clamp Kit 1
  • Fluke 106 Digital Multimeter/i400E Clamp Kit 2
  • Fluke 106 Digital Multimeter/i400E Clamp Kit 3
Discontinued

Key features

Fluke 106 Palm-sized Digital Multimeter

  • Voltage, resistance, continuity, capacitance
  • Input terminal for ac and dc current measurements to 10 A and current
  • Data hold

Fluke i400E AC Current Clamp

  • Compatible with most Fluke multimeters or mV ac measurement tools with these features:
    • 400 mV ac range
    • 19.05 mm banana jack inputs
    • Input accuracy of 2 % or greater to take full advantage of the accuracy of the product
    • Input impedance of >1 M?
  • 1 mV/A ac output guarantees easy current readings on you meter
  • CAT III 600 V safety rating
  • Specially designed to offer maximum utility in a very compact shape
  • Take accurate current readings
This product is discontinued or reclassified

Product overview: Fluke 106 Digital Multimeter/i400E Clamp Kit

The Fluke 106 digital multimeter is made to fit the way you work! It is designed to fit in the palm of your hand and go with you no matter where your job takes you.

The Fluke i400E AC Current Clamp is an ideal tool to extend current measurement. It is designed to work with the new Fluke 101, 106 and 107 palm sized digital multimeters, as well as most Fluke multimeters or other voltage measurement tools that accepts 19.05 mm shrouded banana plugs and has mV ac measurement functionality.

Specifications: Fluke 106 Digital Multimeter/i400E Clamp Kit

Fluke 106 Palm-sized Digital Multimeter

Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, Relative humidity at 0% to 75%. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits])

Accuracy specifications
AC volts1RangeResolutionAccuracy
6.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V
1.0% + 3
DC volts6.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V
0.5% + 3
AC millivolts600.0 mV0.1 mV3.0% + 3
Diode test22.000 V0.001 V10%
Resistance
(Ohms)
400.0 O
4.000 kO
40.00 kO
400.0 kO
4.000 MO
40.00 MO
0.1 O
0.001 kO
0.01 kO
0.1 kO
0.001 MO
0.01 MO
0.5% + 3
0.5% + 2
0.5% + 2
0.5% + 2
0.5% + 2
1.5% + 3
Capacitance350.00 nF
500.0 nF
5.000 µF
50.00 µF
500.0 µF
1000 µF
0.01 nF
0.1 nF
0.001 µF
0.01 µF
0.1 µF
1 µF
2% + 5
2% + 5
5% + 5
5% + 5
5% + 5
5% + 5
Frequency4 Hz
(10 Hz – 100 kHz)
50.00 Hz
500.0 Hz
5.000 kHz
50.00 kHz
100.0 kHz
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz
NA
Duty cycle41% to 99%0.1%NA
AC current
(40 Hz to 200 Hz)
4.000 A
10.00 A
0.001 A
0.01 A
1.5% + 3
DC Current4.000 A
10.00 A
0.001 A
0.01 A
1.5% + 3
1All AC, Hz, and Duty cycle are specified from 1% to 100% of range. Inputs below 1% of range are not specified.
2Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA.
3Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 50 nF range).
4All AC, Hz, and Duty cycle are specified from 1% to 100% of range. Inputs below 1% of range are not specified.
FunctionOverload protectionInput impedance (Nominal)Common mode rejection ratioNormal mode rejection ratio
AC volts600 V 1>10 MO <100 pF 2>60 dB at dc,
50 Hz or 60 Hz
-
AC millivolts600 mV>1M, <100 pF>80 dB at 50 Hz or 60 Hz-
DC volts600 V 1>10 MO <100 pF>100 dB at dc,
50 Hz or 60 Hz
>60 dB at 50 Hz or 60 Hz
16 x 105 V Hz Max
2For mV (AC), input impedance is approximately 1 MO.
General specifications
Maximum voltage between any terminal and earth ground600 V
Display (LCD)6000 counts, updates 3/sec
Battery type2 AAA, NEDA 24A, IEC LR03
Battery life200 hours minimum
Temperature
Operating0 °C to 40 °C
Storage-30 °C to 60 °C
Relative humidity
Operating humidityNon-condensing when <10°C
=90% at 10 °C to 30 °C
=75% at 30 °C to 40 °C
Operating humidity, 40 MO range=80% at 10 °C to 30 °C
=70% at 30 °C to 40 °C
Altitude
Operating2000 m
Storage12,000 m
Temperature coefficient0.1 x (specified accuracy) /°C (<18 °C or >28 °C)
Fuse protection for current inputs11A, 1000V Fast Fuse, Fluke specified part only
Size (H x W x L)142 x 69 x 28mm
Weight200 g
IP ratingIEC 60529: IP 40
SafetyIEC 61010-1: 600 V CAT III, Pollution Degree 2
Electromagnetic environmentIEC 61326-1: Portable
Electromagnetic compatibilityApplies to use the Korea only.  Class A Equipment (Industrial Broadcasting and Communication Equipment)1
1This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or user should take notice of it. This equipment is intended for use in business environments and is not to be used in homes.

Fluke i400E AC Current Clamp

Electrical specifications
AC current range

1 A to 400 A

Output signal 1mV/A ac
Accuracy2.0% ±5 digits (45 Hz to 65 Hz)
2.5% ±5 digits (65 Hz to 400 Hz)
Typical bandwith5 Hz to 20 kHz
Working voltage600 V ac rms, in compliance with IEC 61010-1 and IEC 61010-2-030
Load impedance1 A to 400 A
Maximum non-destructive current600 A
Jaw inner diameter30 mm
Maximum wire size600 MCM
Standard plugs19.04 mm dual banana plugs
Safety specifications
Category ratingIEC 61010-1 and IEC 61010-2-030/IEC 61010-2-031 and
IEC 61010-2-032: 600 V CAT III
Pollution Degree 2
Electromagnetic environmentIEC 61326-1: Portable
General specifications
Output cable length1 m
Operating temperature-10 °C to +50 °C
Storage temperature-30 ºC to +60 ºC
Relative humidity=90% at 10 °C to 530 °C
=75% at 30 °C to 540 °C
=45% at 40 °C to 50 °C
IP ratingIEC 60529: IP30 when jaw closed
Temperature coefficientsAdd 0.1 x specified accuracy for each °C above 28°C or below 18 °C.
Operating altitude2,000 meters
Storage altitude12,000 meters
Vibration requirementsMIL-PRF-28800F, Class 2
Drop test requirements-10 °C, 1m, 6 sides, oak wood
Jaw impact test requirementsFollow EN/IEC 61010-2-032:2012
EMI, RFI, EMCIEC/EN 61326-1
Dimensions (H x W x D)146 x 62 x 34 mm
Weight150 g

Models: Fluke 106 Digital Multimeter/i400E Clamp Kit

Fluke 106/i400E Kit

Includes:
  • Fluke 106 Digital Multimeter
  • Fluke i400E AC Current Clamp
  • Tl75 Hard Point Test Lead Set
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 124.04ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 23.71ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.