Key features

  • Current clamp based on Hall Effect technology that measures both DC and AC current
  • Includes a BNC connector for compatibility with oscilloscopes
  • Current range: 30 mA to 30 A DC, 30 mA to 20 A AC rms
  • Frequency range: DC to 100 kHz (-0.5 dB)
  • CAT III 300 V safety rating

Product overview: Fluke i30s AC/DC Current Clamp

The i30s current clamp is based on Hall Effect technology for use in measurement of both DC and AC current. The i30s may be used in conjunction with oscilloscopes and other suitable recording instruments for accurate non-intrusive current measurement.

Specifications: Fluke i30s AC/DC Current Clamp

Electrical specifications
Specified current range30 mA to 30 A DC, 30 mA to 20 A AC rms
Usable current range5 mA to 30 A DC, 30 mA to 20 A AC rms
Crest factor1.4 in
Output sensitivity100 mV/A
Accuracy (at +25°C)DC ±1 % of reading ±2 mA
AC ± 0.5 dB of reading ±2 mA
Resolution±1 mA
Load impedance> 100 kΩ
Conductor position sensitivity±1% relative to center reading
Frequency rangeDC to 100 kHz (-0.5 dB)
Phase shift below 1 kHz< 2°
Temperature coefficient±0.01% of reading / °C
Power supply9 V Alkaline, MN1604/PP3, 30 hours, low battery indicator
Working voltage (see Safety Standards section)300 V AC rms or DC
General Specifications
Maximum conductor size19 mm diameter
Output connectionSafety BNC connector, supplied with safety 4 mm adapter
Output zeroManual adjust via thumbwheel
Cable length2 m
Operating temperature range0°C to +50°C
Storage temperature range (with battery removed)-20°C to +85°C
Operating humidity15% to 85% (non-condensing)
Weight250 g
SafetyIEC 61010-1, Pollution Degree 2
IEC 61010-2- 032: CAT III 300V
Use of the probe on uninsulated conductors is limited to 300 V ac rms or dc andfrequencies below 1 kHz.
EMC CompatibilityIEC 61326-1: Portable Electromagnetic Environment

Models: Fluke i30s AC/DC Current Clamp

Fluke i30s

AC/DC Current Clamp


Buy it
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 32.01ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • y_2025, m_3, d_20, h_7
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_2
  • loc_en_US, sid_3739329953844, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 23.34ms
  • REVIEWS, PRODUCT
Please enable cookies to view product reviews.