Fluke TiR27 Infrared Camera
Key features
Superior image quality
- Delivers the clear, crisp images needed to find problems fast with its 240 x 180 infrared resolution.
- Identify even the smallest temperature differences that could indicate problems with thermal sensitivity (NETD).
- Automatic alignment (parallax correction) of visual and infrared images with Fluke patented IR-Fusion®
- Optional telephoto and wide angle lenses available for added versatility and special applications (easily installable in the field).
Easy to use
- Field replaceable batteries give you maximum flexibility no matter where your work takes you.
- Intuitive, three-button menu is easy to use—simply navigate with the push of a thumb.
- No need to carry pen and paper—record findings by speaking into the imager. Voice annotations can be recorded with every image you take. Voice comments are saved along with individual images for future reference.
- One-handed focus capability, emissivity correction, reflected background temperature compensation, and transmission correction increase the accuracy of measurements in most situations.
- Adjustable hand strap for left-or right-handed use.
- Everything needed to get started is included.
Rugged
- Optimized for field use in challenging work environments.
- Engineered and tested to withstand a 2 m drop for the ultimate peace of mind - When was the last time you dropped a tool or piece of equipment?
- Withstands dust and water—tested to an IP54 rating.
Product overview: Fluke TiR27 Infrared Camera
When You Need to See the Smallest Visual and Thermal Details from Short or Long Distance
The TiR27, a thermal imaging camera offers 240 x 180 resolution with IR-Fusion® Technology – the blending of digital and infrared images into a single image and delivers crisp quality images. The TiR27 also produces partially transparent images that help identify issues and report findings easier (AutoBlend™). With thermal sensitivity of ≤ 0.045 °C at 30 °C (50 mK) and a temperature range from -20 ° to 150 °C (-4 ° to 302 °F) the TiR27 is ideal for inspectors, energy auditors, restoration and remediation professionals and weatherization experts who need to see the most challenging infrared details.
Take the Guesswork Out of Infrared Troubleshooting
Whether you are searching for energy waste, leaky roofs or moisture problems, the TiR27 takes the guesswork out of finding problems. Field installable telephoto and wide angle lenses are available for added versatility for special applications and voice annotation makes pen and paper no longer necessary. With its rugged body, integrated lens cover, protected display and 2 meter drop test, the TiR27 is designed to handle the harshest environments. Make no mistake on your next building inspection with the TiR27.
For applications that require a high temperature range and low thermal sensitivity (NETD), the Fluke Ti200 is an alternative choice. It features wireless connectivity for quick and easy sharing of images, LaserSharp® Auto Focus for consistently in-focus images – every, single, time and a ruggedized high resolution 640 x 480 capacitive touch screen for quick menu navigation.
As always, Fluke SmartView® Software is included at no additional charge.
Specifications: Fluke TiR27 Infrared Camera
Temperature | ||
Temperature measurement range (not calibrated below -10°C) | -20°C to +150°C (-4°F to +302°F) | |
Temperature measurement accuracy | ±2°C or 2% (at 25°C nominal, whichever is greater) | |
On-screen emissivity correction | Yes | |
On-screen reflected background temperature compensation | Yes | |
On-screen transmission correction | Yes | |
Imaging Performance | ||
Detector type | Focal Plane Array, uncooled microbolometer, 240 x 180 pixels | |
Total pixels | 43,200 | |
Thermal sensitivity (NETD) | ≤ 0.045°C at 30°C target temp. (45 mK) | |
Infrared spectral band | 7.5 μm to 14 μm (long wave) | |
Visual (visible light) camera | Industrial performance 2.0 megapixel | |
Minimum focus distance | 46 cm (approx. 18 in) | |
Standard infrared lens type | Field of view | 23° x 17° |
Spatial resolution(IFOV) | 1.67 mRad | |
Minimum focus distance | 15 cm (approx. 6 in) | |
Optional telephoto infrared lens type | Field of view | 11.5° x 8.7° |
Spatial resolution(IFOV) | 0.84 mRad | |
Minimum focus distance | 45 cm (approx. 18 in) | |
Optional wide-angle infrared lens type | Field of view | 46° x 34° |
Spatial resolution(IFOV) | 3.34 mRad | |
Minimum focus distance | 7.5 cm (approx. 3 in) | |
Focus mechanism | Manual, one-handed Smart Focus capability | |
Image Presentation | ||
Palettes | Standard | Ironbow, blue-red, high contrast, amber, amber inverted, hot metal, grayscale, grayscale inverted |
Ultra Contrast™ | Ironbow ultra, blue-red ultra, high contrast ultra, amber ultra, amber inverted ultra, hot metal ultra, grayscale ultra, grayscale inverted ultra | |
Level and span | Smooth auto-scaling and manual scaling of level and span | |
Fast auto toggle between manual and auto modes | Yes | |
Fast auto-rescale in manual mode | Yes | |
Minimum span (in manual mode) | 2.0°C (3.6°F) 3°C (5.4°F) | |
IR-Fusion® Information | ||
Automatically aligned (parallax corrected) visual and IR blending | Yes | |
Picture-In-Picture (PIP) | Three levels of on-screen IR blending displayed in center of LCD | |
Full screen infrared | Three levels of on-screen IR blending displayed in center of LCD | |
Color alarms (temperature alarms) | Dewpoint temperature color alarm (user-selectable) | |
Image Capture and Data Storage | ||
Voice annotation | 60 seconds maximum recording time per image; reviewable playback on imager | |
The TiR27 allows user to adjust palette, blending, level, span, IR-Fusion® mode, emissivity, and reflected background temperature compensation, and transmission correction on a captured image before it is stored. | ||
Image capture, review, save mechanism | One-handed image capture, review, and save capability | |
Storage medium | SD Memory Card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked visual images each with 60 seconds voice annotations, or 3000 basic bitmap (.bmp) images, or 3000 jpeg (.jpeg) images; transferrable to PC via included multi-format USB card reader | |
File formats | Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2) No analysis software required for non-radiometric (.bmp and .jpeg) files | |
Export file formats w/ SmartView® software | JPEG, JPG, JPE, JFIF, BMP, GIF, DIB, PNG, TIF, and TIFF | |
Memory review | Thumbnail view navigation and review selection | |
General Specifications | ||
Operating temperature | -10°C to +50°C (14°F to 122°F) | |
Storage temperature | -20°C to +50°C (-4°F to 122°F) without batteries | |
Relative humidity | 10% to 95% non-condensing | |
Display | 9.1 cm (3.6 in) diagonal landscape color VGA (640 x 480) LCD with backlight (selectable bright or auto) | |
Controls and adjustments | User selectable temperature scale (°C/°F) Language selection Time/Date set Emissivity selection Reflected background temperature compensation Transmission correction User selectable hot spot and cold spot, and center point on the image (other custom markers and shapes in SmartView® software) Dewpoint (low temperature) color alarm User selectable backlight: "Full Bright or "Auto Information display preference | |
Software | SmartView® full analysis and reporting software included | |
Batteries | Two lithium ion rechargeable smart battery packs with five-segment LED display to show charge level | |
Battery life | Four+ hours continuous use per battery pack (assumes 50% brightness of LCD) | |
Battery charge time | 2.5 hours to full charge | |
AC battery charging | Two-bay AC battery charger (110 V AC to 220 V AC, 50/60 Hz) (included), or in-imager charging. AC mains adapters included. Optional 12 V automotive charging adapter. | |
AC operation | AC operation with included power supply (110 V AC to 220 V AC, 50/60 Hz). AC mains adapters included. | |
Power saving | Sleep mode activated after five minutes of inactivity, automatic power off after 30 minutes of inactivity | |
Safety standards | CSA (US and CAN): C22.2 No. 61010-1-04, UL: UL STD 61010-1 (2nd Edition), ISA: 82.02.01 | |
Electromagnetic compatibility | Meets all applicable requirements in EN61326-1:2006 | |
C Tick | IEC/EN 61326-1 | |
US FCC | CFR 47, Part 15 Class B | |
Vibration | 0.03 g2/Hz (3.8 grms), IEC 68-2-6 | |
Shock | 25 g, IEC 68-2-29 | |
Drop | 2 m (6.5 ft) with standard lens | |
Dimensions (H x W x L) | 27.7 x 12.2 x 17.0 cm (10.9 x 4.8 x 6.7 in) | |
Weight (battery included) | 1.05 kg (2.3 lb) | |
Enclosure rating | IP54 (protected against dust, limited ingress; protection against water spray from all directions) | |
Warranty | Two-years (standard) | |
Recommended calibration cycle | Two-years (assumes normal operation and normal aging) | |
Supported languages | Czech, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish |
Models: Fluke TiR27 Infrared Camera
Includes:
- Building Diagnostic Thermal Imaging camera with standard infrared lens
- AC power supply and battery pack charger (including mains adapters)
- Two, rugged lithium ion smart battery packs
- SD memory card
- Multi-format USB memory card reader for downloading images into your computer
- SmartView® software with free software upgrades for life
- Rugged, hard carrying case
- Soft transport bag
- Adjustable hand strap
- Printed users manual
- Warranty registration card
Manuals + resources: Fluke TiR27 Infrared Camera
- Fluke Infrared Camera: IR-Fusion® Technology
- Fluke thermal imaging: just another day on the job
- Fluke smartview 3d-IR: IR analysis and reporting software
- Fluke Thermal Imaging: For Building Inspectors - Introduction
- Fluke Thermal Imaging: For Building Inspectors - Technology
- Fluke Thermal Imaging for Building Inspectors - Building Envelope
- Fluke Thermal Imaging: For Building Inspectors - HVAC
- Fluke Thermal Imaging: For Building Inspectors - Moisture
- Thermal Imagers for Building Inspectors - Commercial Properties