PPC4 Pressure Controller / Calibrator

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 120.98ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;

Key features

  • Premium performance, supporting ranges up to 14 MPa and 4 ppm control precision with 50:1 turndown
  • Low measurement uncertainty, as low as +/- 0.008% RDG
  • Real-time uncertainty calculation.
  • Suitable for cal lab benchtop to automated production testing.
  • Advanced user interface interface with color display and easy navigation or basic economical interface.

Product overview: PPC4 Pressure Controller / Calibrator

Priority Gold Instrument CarePlan

Make sure to ask your account manager about the Fluke Calibration Priority Gold CarePlan

A Fluke Calibration Priority Gold CarePlan puts you in control of your downtime and in control of your business, with calibration services and other offerings.

Video Player is loading.
Current Time 0:00
Duration 0:00
Loaded: 0%
Stream Type LIVE
Remaining Time 0:00
 
1x
    • Chapters
    • descriptions off, selected
    • subtitles off, selected

      Learn more

      The basic and advanced PPC4 includes all the pressure transducer calibration features you expect in a state-of-the-art digital pressure calibrator

      • Portable pressure calibrator, rugged enough for mobile applications and standard shipment without special packaging
      • Advanced user interface with full support in 11 languages
      • Covers the absolute range of 1 kPa (0.15 psi) to 14 MPa (2,000 psi) and gauge equivalent, including very low differential pressure
      • Control precision to ± 4 ppm of Q-PRT span, default ± 0.005% of Autoranged range
      • Three different Q-RPT measurement classes available to fit different performance requirements
      • Measured and delivered pressure uncertainties calculated real-time and available on remote and local interfaces
      • Q-RPTs can be located in an external RPM4 so that PPC4 does not need to be shipped or removed for recalibration
      • AutoRange feature optimizes and sets measurement, control and safety features for the specific range of the test beign run with a few simple entries
      • Dynamic and static control modes with default or user specified parameters
      • Common remote command protocol with Fluke Calibration PPC3 pressure controllers
      • RS-232 and front panel USB included standard, IEEE488.2 optional
      • Instantaneous switching between absolute, gauge and bidirectional gauge modes without added hardware or calibration requirements
      • Instantaneous switching between control and measure modes with no pressure discontinuity
      • Automated AutoZeroing while vented at atmospheric pressure
      • 16 SI and US pressure units as well as user definable uits
      • Simple, objective pressure “ready/not ready indicator with user adjustable criteria
      • Automatic pressure head correction
      • On-board, programmable calibration sequences with UUT tolerance testing
      • Automated leak testing routines
      • Valve drivers option for system design
      • Automated self purging liquid trap (SPLT) accessory available for protection against liquid contamination
      • Flash memory for simple and free embedded software upgrades from flukecal.com
      • …and much more

      Specifications: PPC4 Pressure Controller / Calibrator

      PPC4 General Specifications
      Power requirements100 to 240 VAC 50/60 Hz, 70 W max consumption
      Operating temperature range15 to 40 °C (50 °F to 104 °F)
      Storage temperature range- 20 to 70 °C (-4 °F to 158 °F)
      VibrationMeets MIL-T-28800D
      Weight16.6 kg (36.5 lb)
      Dimensions
      PPC4:19 cm H x 35 cm W x 41 cm D (7.5 in. x 13.8 in. x 16.1 in.)
      PPC4-ui:19 cm H x 35 cm W x 45 cm D (7.5 in. x 13.8 in. x 17.7 in.)
      Remote communication interfacesRS232 (COM1, COM2), USB (front panel)
      Optional: IEEE-488.2 or Ethernet and USB (Rear Panel)
      Languages Supported (Advanced UI)Chinese (simplified), Chinese (traditional), Czech, English, French, German, Italian, Japanese, Portuguese, Russian and Spanish
      Pressure rangesVacuum to 14 MPa (2,000 psi)
      Operating mediumAny clean, dry, non-corrosive gas
      Supply pressureMaximum desired set pressure + 70 kPa (10 psi)
      Exhaust pressureAtmosphere or vacuum for pressures under 5 psig (35 kPa gauge)
      Pressure connections
      TEST (+), TEST (-):1/8 in. NPT F
      SUPPLY:1/8 in. NPT F
      EXHAUST:3/8 in. NPT F
      ATM:10-32 UNF
      Pressure limits
      Maximum working test pressure:103% Hi Q-RPT maximum
      Maximum pressure on TEST port without damage:115 % Hi Q-RPT maximum
      Utility sensor (if present)
      Resolution:0.001% of span
      Precision:0.1% of span
      Pressure measurement
      Warm up time30 minute temperature stabilization recommended for best performance from cold power up.
      ResolutionTo 1 ppm, user adjustable
      Acceleration affect± 0.008 % /g maximum, worst axis. Allows operation at ± 20° from reference plane without significant effect.
      Predicted one year stability1± 0.005% of reading (Gauge mode or Absolute mode with regular use of AutoZero)
      Precision2Full Scale Standard Q-RPT Class
      ± 0.01 % of AutoRanged span4
      Standard Q-RPT Class
      ± 0.008 % of reading5
      Premium Q-RPT Class
      ± 0.005 % of reading7
      Measurement Uncertainty3Full Scale Standard Q-RPT Class
      ± 0.015 % of AutoRanged span4
      Standard Q-RPT Class
      ± 0.01 % of reading6
      Premium Q-RPT Class
      ± 0.008 % of reading8


      1 Predicted Q-RPT measurement stability limit (k=2) over one year assuming regular use of AutoZero function. AutoZero occurs automatically in gauge mode whenever vented, by comparison with barometric reference in absolute mode. Absolute mode predicted one year stability without AutoZ is ± (0.005 % Q-RPT span + 0.005 % of reading).
      2 Combined linearity, hysteresis, repeatability. Add + 1 Pa (0.00015 psi) in gauge mode with an Axxx (absolute) Q-RPT for the resolution and short term stability of the on-board barometer.
      Maximum deviation of the Q-RPT indication from the true value of applied pressure including precision, predicted one year stability limit, temperature effect and calibration uncertainty, combined and expanded (k=2) following the ISO “Guide to the Expression of Uncertainty in Measurement.
      % of AutoRanged span, but with AutoRanged span no lower than 30 % of Q-RPT span (10 % with BG15K and G15K).
      5 ±0.008 % of reading from 30 % to 100 % of Q-RPT span. Below 30 %; ±0.0024 % of Q-RPT span.
      6 ±0.01 % of reading from 30 % to 100 % of Q-RPT span. Below 30 %; ±0.0030 % of Q-RPT span.
      7 ±0.005 % of reading from 30 % to 100 % of any AutoRanged span between 30 % and 100 % of maximum Q-RPT span. Below 30 %; ±0.0015 % of AutoRanged span, or 0.0005 % of Q-RPT span, whichever is greater.
      8 ±0.008 % of reading from 30 % to 100 % of any AutoRanged span between 30 % and 100 % of maximum Q-RPT span. Below 30 %; ±0.0024 % of AutoRanged span, or 0.0007 % of Q-RPT span, whichever is greater.
      Note: Technical note 8050TN11 provides a detailed description of PPC4 Q-RPT uncertainties.

      Pressure Control Modes and Ready Indication
      Static modeSets pressure to target within hold limit and shuts off control in a closed test volume.
      Pressure is “ready when inside hold limit and stability test is met.
      Dynamic modeSets pressure within hold limit and continuously adjusts pressure to remain at target value. Pressure is “ready when inside hold limit.
      Control parametersHold limit, stability limit (default values can be adjusted by user)
      Pressure Control Performance
      Control precision± 4 ppm of Q-RPT span or ± 0.4 ppm of HI Q-RPT span, whichever is greater.
      Lowest controllable pressure in dynamic modeGauge: Zero set by automated venting. Lowest point above or below zero limited only by Q-RPT resolution and control precision. Absolute, negative gauge: ±0.05% of Q-RPT span or 1 kPa (0.15 psia), whichever is greater
      Ultimate pressure
      (absolute, negative gauge)
      With low ultimate pressure option:
      50 Pa (0.5 mbar, 0.007 psia) typical, depending on vacuum pump and connections
      Without low ultimate pressure option:
      200 to 700 Pa (2 to 7 mbar, 0.03 to 0.1 psia) depending on vacuum pump and connections
      Typical pressure setting ready time (0.005 % hold limit, 50 cc test volume)15 to 35 s
      Slew time
      (ATM to FS with 50 cc test volume)
      30 s
      Typical test volumeHI Q-RPT span: 0-2 MPa [0-300 psi]: 0-1,000 cc
      HI Q-RPT span: 3.5-14 MPa [500-2000 psi]: 0-500 cc

      Models: PPC4 Pressure Controller / Calibrator

      PPC4-ui xxxxy/zzzzy
      PPC4 Controller/Calibrator with Advanced user interface (color display, full keypad, point-and-click knob)

      Buy it
      To configure:
      • Define the maximum controlled pressure required
        (up to 14 MPa)
      • Select the Q-RPT or utility sensor (xxxx) for the maximum pressure identified and choose its class (y) from the “Accessory” table below:
      Full Scale Standard Q-RPT
      • Standard Q-RPT
      • Premium Q-RPT
      • Utility sensor
      • Select a Lo Q-RPT (zzzz) if desired.
        • Full Scale Standard Q-RPT
        • Standard Q-RPT
        • Premium Q-RPT
      • Select options
        • Units – SI or US nominal ranges
        • CE compliance
        • Remote interface – add IEEE-488.2
      For detailed information about configuration options, download the PPC4 product brochure.
      PPC4 xxxxy/zzzzy
      PPC4 Controller/Calibrator with Basic user interface (2 x 20 character, 10 key)

      Buy it
      To configure:
      • Define the maximum controlled pressure required
        (up to 14 MPa)
      • Select the Q-RPT or utility sensor (xxxx) for the maximum pressure identified and choose its class from the “Accessory” table below.
      • Select a Lo Q-RPT (zzzz) if desired.
      • Select options:
        • Units – SI or US nominal ranges
        • CE compliance
        • Remote interface – add IEEE-488.2
      For detailed information about configuration options, download the PPC4 product brochure.
      A1.4M
      PPC4 Quartz Reference Pressure Transducer (Q-RPT)

      Buy it
      SI Version
      Maximum Range (kPa) Absolute: 1,400
      Maximum Range (kPa) Gauge: 1,400

      US Version
      Maximum Range (psi) Absolute: 200
      Maximum Range (psi) Gauge:200
      A100K
      PPC4 Quartz Reference Pressure Transducer (Q-RPT)

      Buy it
      SI Version
      Maximum Range (kPa) Absolute: 110
      Maximum Range (kPa) Gauge: 10

      US Version
      Maximum Range (psi) Absolute: 16
      Maximum Range (psi) Gauge: 1.5
      A10M HI Q-RPT
      PPC4 Quartz Reference Pressure Transducer (Q-RPT)

      Buy it
      SI Version
      Maximum Range (kPa) Absolute: 10,000
      Maximum Range (kPa) Gauge: 10,000

      US Version
      Maximum Range (psi) Absolute: 1,500
      Maximum Range (psi) Gauge: 1,500
      A14M Hi Q-RPT
      PPC4 Quartz Reference Pressure Transducer (Q-RPT)

      Buy it
      SI Version
      Maximum Range (kPa) Absolute: 14,000
      Maximum Range (kPa) Gauge: 14,000

      US Version
      Maximum Range (psi) Absolute: 2,000
      Maximum Range (psi) Gauge:2,000
      A160K
      PPC4 Quartz Reference Pressure Transducer (Q-RPT)

      Buy it
      SI Version
      Maximum Range (kPa) Absolute: 160
      Maximum Range (kPa) Gauge: 60

      US Version
      Maximum Range (psi) Absolute: 23
      Maximum Range (psi) Gauge: 8
      A200K
      PPC4 Quartz Reference Pressure Transducer (Q-RPT)

      Buy it
      SI Version
      Maximum Range (kPa) Absolute: 200
      Maximum Range (kPa) Gauge: 100

      US Version
      Maximum Range (psi) Absolute: 30
      Maximum Range (psi) Gauge: 15
      A2M
      PPC4 Quartz Reference Pressure Transducer (Q-RPT)

      Buy it
      SI Version
      Maximum Range (kPa) Absolute: 2,000
      Maximum Range (kPa) Gauge: 2,000

      US Version
      Maximum Range (psi) Absolute: 300
      Maximum Range (psi) Gauge: 300
      A3.5M
      PPC4 Quartz Reference Pressure Transducer (Q-RPT)

      Buy it
      SI Version
      Maximum Range (kPa) Absolute: 3,500
      Maximum Range (kPa) Gauge: 3,500

      US Version
      Maximum Range (psi) Absolute: 500
      Maximum Range (psi) Gauge: 500
      A350K
      PPC4 Quartz Reference Pressure Transducer (Q-RPT)

      Buy it
      SI Version
      Maximum Range (kPa) Absolute: 350
      Maximum Range (kPa) Gauge: 250

      US Version
      Maximum Range (psi) Absolute: 50
      Maximum Range (psi) Gauge: 35
      A700K
      PPC4 Quartz Reference Pressure Transducer (Q-RPT)

      Buy it
      SI Version
      Maximum Range (kPa) Absolute: 700
      Maximum Range (kPa) Gauge: 700

      US Version
      Maximum Range (psi) Absolute: 100
      Maximum Range (psi) Gauge: 100
      A7M
      PPC4 Quartz Reference Pressure Transducer (Q-RPT)

      Buy it
      SI Version
      Maximum Range (kPa) Absolute: 7,000
      Maximum Range (kPa) Gauge: 7,000

      US Version
      Maximum Range (psi) Absolute: 1,000
      Maximum Range (psi) Gauge: 1,000
      BA100K
      PPC4 Quartz Reference Pressure Transducer (Q-RPT)

      Buy it
      SI Version
      Maximum Range (kPa) Absolute: 7 to 110
      Maximum Range (kPa) Gauge: n/a

      US Version
      Maximum Range (psi) Absolute: 10.2 to 16
      Maximum Range (psi) Gauge: n/a
      BG15K
      PPC4 Quartz Reference Pressure Transducer (Q-RPT)

      Buy it
      SI Version
      Maximum Range (kPa) Absolute: n/a
      Maximum Range (kPa) Gauge:15

      US Version
      Maximum Range (psi) Absolute: n/a
      Maximum Range (psi) Gauge: 2.2
      G100K
      PPC4 Quartz Reference Pressure Transducer (Q-RPT)

      Buy it
      SI Version
      Maximum Range (kPa) Absolute: n/a
      Maximum Range (kPa) Gauge: 100

      US Version
      Maximum Range (psi) Absolute: n/a
      Maximum Range (psi) Gauge: 15
      G15K
      PPC4 Quartz Reference Pressure Transducer (Q-RPT)

      Buy it
      SI Version
      Maximum Range (kPa) Absolute: n/a
      Maximum Range (kPa) Gauge:15

      US Version
      Maximum Range (psi) Absolute: n/a
      Maximum Range (psi) Gauge: 2.2
      G200K
      PPC4 Quartz Reference Pressure Transducer (Q-RPT)

      Buy it
      SI Version
      Maximum Range (kPa) Absolute: n/a
      Maximum Range (kPa) Gauge: 200

      US Version
      Maximum Range (psi) Absolute: n/a
      Maximum Range (psi) Gauge: 30
      RPM4
      Reference pressure monitor for external Q-RPTs

      Buy it
      • bvseo_sdk, p_sdk, 3.2.1
      • CLOUD, getContent, 83.18ms
      • QUESTIONS, PRODUCT
      • bvseo-msg: HTTP status code of 404 was returned;
      • bvseo_sdk, p_sdk, 3.2.1
      • CLOUD, getReviews, 22.02ms
      • REVIEWS, PRODUCT
      • bvseo-msg: HTTP status code of 404 was returned;
      Please enable cookies to view product reviews.