52120A Transconductance Amplifier

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 30.85ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;

Key features

Read more

Product overview: 52120A Transconductance Amplifier

Priority Gold Instrument CarePlan

Make sure to ask your account manager about the Fluke Calibration Priority Gold CarePlan

A Fluke Calibration Priority Gold CarePlan puts you in control of your downtime and in control of your business, with calibration services and other offerings.

Video Player is loading.
Current Time 0:00
Duration 0:00
Loaded: 0%
Stream Type LIVE
Remaining Time 0:00
 
1x
    • Chapters
    • descriptions off, selected
    • subtitles off, selected

      Learn more

      The 52120A is designed for users whose ability to address their calibration workload may be
      limited by the output current, accuracy and drive capability of their present test equipment,
      including:

      • Calibration professionals in a calibration/standards lab or an electrical utility
      • Manufacturers of power/energy instrumentation and meters, power quality analyzers or power converters
      • Users of electrical test and measurement equipment

      The 52120A operates as a transconductance amplifier with:

      • 5522A/5502A/5520A/5500A Multi-Product Calibrators
      • 5730A*/5700A/5720A Multifunction Calibrator
      • 6105A*/6100B* Electrical Power Standard
      • 5080A Multi-Product Calibrator
      • 9100 Universal Calibration System
      • Any calibrator, signal generator or power supply capable of sourcing 2 V or 200 mA, dc or ac

      *Special closed-loop operating mode

      You may also operate your 52120A in closed-loop mode, seamlessly communicating with your Fluke Calibration 6105A or 6100B Electrical Power Standard to deliver enhanced 52120A accuracy.

      Specifications: 52120A Transconductance Amplifier

      Operating limits
      Output ranges2 A, 20 A, 120 A (100 A dc)
      Input current range200 mA, 200 mA, 120 mA (100 mA dc)
      Current gain10, 100, 1000
      Input voltage range2 V, 2 V, 1.2 V (1.0 V dc)
      Transconductance1,10,100 Siemens
      FrequencyTo 10 kHz
      Maximum output compliance voltage4.5 Vrms (6.4 Vpeak)
      Inductive drive capability:1 mH load
      Output isolation, current terminal to earth600 Vrms, 850 Vpeak, dc to 850 Hz
      Performance specifications
      AC accuracy, closed loop with 6105ATo 140 ppm
      DC accuracy, standaloneTo 160 ppm
      AC accuracy, standaloneTo 350 ppm
      Phase angle accuracy0.006°
      Load dependent phase angle shift<0.001° @ 60 Hz
      General specifications
      Input line voltage range100 V to 240 V with up to ±10 % fluctuations
      Transient overvoltageImpulse withstand (overvoltage); Category II of IEC 60364-4-443
      Frequency47 Hz to 63 Hz
      Maximum consumption< 1500 VA
      Calibration DocumentationReport of calibration with data included; 17025 accredited report optional
      Dimensions with feet (H x W x L)192 mm x 432 mm x 645 mm  (7.6 inches x 17 inches x 25.5 inches)
      Dimensions without feet (H x W x L)178 mm x 432 mm x 645 mm  (7 inches x 17 inches x 25.5 inches)
      Weight25 kg (54 lb.)
      Design standards and complianceDesigned to EN 61010-1: 2010, CAN/CSA 22.2 No 61010.1-04, ANSI/UL 61010-1:2004, EN 61326-1:2006 CE marked, CSA listed
      Operating temperature5 °C to 35 °C
      Calibration temperature range16 °C to 30 °C
      Warm up time1 hour
      Safe operating max. relative humidity (non-condensing)<80 % 5 °C to 31 °C ramping linearly down to 50  % at 35 °C
      Operating altitude0 m to 2,500 m
      Shock and vibrationMIL-PRF-28800F class 3
      Specification confidence level99%

      Models: 52120A Transconductance Amplifier

      52120A
      Transconductance Amplifier

      Buy it
      • bvseo_sdk, p_sdk, 3.2.1
      • CLOUD, getContent, 23.85ms
      • QUESTIONS, PRODUCT
      • bvseo-msg: HTTP status code of 404 was returned;
      • bvseo_sdk, p_sdk, 3.2.1
      • CLOUD, getReviews, 27.78ms
      • REVIEWS, PRODUCT
      • bvseo-msg: HTTP status code of 404 was returned;
      Please enable cookies to view product reviews.