Product overview: 5080A High Compliance Multi-Product Calibrator

Priority Gold Instrument CarePlan

Make sure to ask your account manager about the Fluke Calibration Priority Gold CarePlan

A Fluke Calibration Priority Gold CarePlan puts you in control of your downtime and in control of your business, with calibration services and other offerings.

Video Player is loading.
Current Time 0:00
Duration 0:00
Loaded: 0%
Stream Type LIVE
Remaining Time 0:00
 
1x
    • Chapters
    • descriptions off, selected
    • subtitles off, selected

      Learn more

      Accurate, reliable analog meter calibration


      The 5080A Multi-Product Calibrator calibrates your analog workload accurately and reliably, thanks to its high voltage and current compliance. With maximum burden up to 800 mA for ac/dc voltage, and voltage up to 50 V for ac/dc current, 5080A calibrators can drive a wide range of analog meters.

      Options and accessories expand workload coverage

      Options and accessories enable you to use the 5080A Multi-Product Calibrator to calibrate an even broader workload, including:

      • Clamp meters. The 9100-200 10/50 turn coil and 5500A/COIL 50-turn current coil enables the 5080A to calibrate most popular clamp meters at currents up to 1000 A rms amps.
      • Oscilloscopes. Oscilloscope calibration to 200 MHz quickly, easily, and cost effectively. Verify dynamic response, bandwidth, timing, multiple triggering functions, and input resistance.
      • Megohm meters. This option sources high ohms, high voltage resistors up to 18 G ohms. It also measures high voltage outputs.

      Protective circuits prevent damage

      Mains voltage inadvertently applied to a calibrator’s output terminals can cause extensive damage, requiring costly repairs. Electrical protection for calibrator outputs is vital for daily operation. The 5080A calibrator’s innovative protection circuitry prevents it from being damaged by reversed input voltage, so you can use it with confidence day after day.

      Highest voltage and current compliance

      The 5080A has the highest voltage and current compliance of any calibrator in the Fluke Calibration multi-product and multifunction calibrator families, making it an ideal solution for calibrating analog meters and other instruments requiring higher drive capability for proper operation.

      Maximum burden or compliance voltage
      Functions
      ModelDC voltageAC voltageDC currentAC current*
      5080A600 mA800 mA50 V44 V
      910020 mA20 mA4 V4 V
      5500A10 mA10 mA4.5 V3 V
      5520A10 mA10 mA7 V5 V
      5700A50 mA50 mA10 V7 V
      5720A50 mA50 mA10 V7 V

      * With AC LCOMP on

      Automate the 5080A Multi-Product Calibrator to increase efficiency and throughput

      For the full spectrum of calibration automation and asset management, choose MET/CAL software

      The solutions you need, from the leader in calibration

      Fluke Calibration is a premium brand, well known around the world for its accurate, dependable, high quality products. Long known as a leader in dc and low frequency ac calibration, Fluke Calibration is also recognized for its offerings in temperature, pressure, power, process, and rf calibration. Fluke Calibration provides the calibrators, standards, software, service, support and training you need for a complete solution in your cal lab.

      Specifications: 5080A High Compliance Multi-Product Calibrator

      Technical Specifications
      Voltage DCRange: 0 to ±1020V
      Best 1 Year Specification: ±0.025% of setting
      Current DCRange: 0 to ±20.5A
      Best 1 Year Specification: ±0.025% of setting
      ResistanceRange: 0 to 190 MO, 19 values in x1 and x1.9
      Best 1 Year Specification: ±0.025% of setting
      Voltage ACRange: 1 mV to 1020V
      45Hz to 1 kHz, Sine
      Best 1 Year Specification: ±0.25% of setting
      Current ACRange:29 mA to 20.5A
      45 Hz to 1 kHz, Sine
      Best 1 Year Specification: ±0.25% of setting
      DC PowerRange:10.9 mW to 20.5 kW
      Best 1 Year Specification: ±0.125% of setting
      AC PowerRange: 10.9 mW to 20.5 kW
      45-65 Hz, PF=1
      Best 1 Year Specification: ±0.36% of setting
      PhaseRange: 0 to ± 179.99°
      45 Hz to 1 kHz
      Best 1 Year Specification: ±0.25° of setting
      FrequencyRange: 45 Hz to 1 kHz
      Best 1 Year Specification: ±50 ppm of setting
      General Specifications
      Warm up Time Twice the time since last warmed up, to a maximum of 30 minutes
      Settling TimeLess than 5 seconds for all functions and ranges except as noted
      Standard InterfacesRS-232 and Ethernet
      Temperature PerformanceOperating: 0°C to 50°C
      Calibration (tcal):15°C to 35°C
      Storage:-20°C to +70°C
      Temperature CoefficientTemperature coefficient for temperatures outside tcal ±5 °C is 10 % of the stated specification per °C for temperatures in the range of 0 °C to 35 °C. Above 35 °C, the temperature coefficient is 20 % of the stated specification per °C.
      Relative HumidityOperating: <80% to 30°C, <70% to 40°C, <40% to 50°C
      Storage:<925%, non-condensing
      AltitudeOperating: 2,000m (6,500 ft) maximum
      Non-operating: 12,200m (40,000 ft) maximum
      SafetyMeets EN. 61010-1:2001, CAN/CSA-C22.2 No. 61010-1-04, UL 61010-1: 2004
      Analog Low Isolation20V
      EMCMeets EN613261:2006.
      Line PowerLine Voltage (selectable): 100V, 120V, 220V, 240V
      Line Frequency: 47 to 63 Hz
      Line Voltage Variation: + 25% about line voltage setting
      Power Consumption600 VA
      Calibration DocumentationReport of calibration with data included; 17025 accredited report optional
      DimensionsHeight:19.3 cm (7.6 in)
      Width:43.2 cm (17 in), 44.3 cm (17.5 in) including handles
      Depth:53.8 cm (21.2 in)
      Weight (without options)22 kg (48 lbs.)
      Absolute Uncertainty Definition
      The specifications include stability, temperature coefficient, linearity, line and load regulation, and the traceability of the external standards used for calibration. It is not necessary to add anything to determine the total specification for the temperature range indicated.
      Specification Confidence Interval99%

      Models: 5080A High Compliance Multi-Product Calibrator

      5080A
      Multi-Product Calibrator

      Buy it
      5080A/MEG
      Multi-Product calibrator with Megohm Meter Calibration Option

      Buy it
      5080A/SC
      Multi-Product Calibrator with Oscilloscope Calibration Option

      Buy it
      5080A/SC/MEG
      Multi-Product Calibrator with Megohm Meter and Oscilloscope Calibration Option

      Buy it
      5080A -> 5080A/MEG

      Upgrade 5080A to 5080A/MEG - Installable only at Fluke service centers for extra installation and calibration cost.


      Buy it
      5080A -> 5080A/SC/MEG
      Upgrade 5080A to 5080A/SC/MEG - Installable only at Fluke service centers for extra installation and calibration cost.

      Buy it
      9100-200
      10/50 Turn Coils

      Buy it
      • bvseo_sdk, p_sdk, 3.2.1
      • CLOUD, getContent, 122.73ms
      • QUESTIONS, PRODUCT
      • bvseo-msg: HTTP status code of 404 was returned;
      • bvseo_sdk, p_sdk, 3.2.1
      • CLOUD, getReviews, 23.38ms
      • REVIEWS, PRODUCT
      • bvseo-msg: HTTP status code of 404 was returned;
      Please enable cookies to view product reviews.