Key features

Read more

Product overview: 8558A 8.5 Digit Multimeter

Priority Gold Instrument CarePlan

Make sure to ask your account manager about the Fluke Calibration Priority Gold CarePlan

A Fluke Calibration Priority Gold CarePlan puts you in control of your downtime and in control of your business, with calibration services and other offerings.

Video Player is loading.
Current Time 0:00
Duration 0:00
Loaded: 0%
Stream Type LIVE
Remaining Time 0:00
 
1x
    • Chapters
    • descriptions off, selected
    • subtitles off, selected

      Learn more

      Accurate data, delivered amazingly fast


      Shorter test time on the 8588A/8558A high-speed digital platform enables you to increase throughput, improve yield and realize a greater return on your investment. The 8588A/8558A digitizes to memory at 200 nanoseconds per reading and delivers 4.5 digit data to a PC via USB, Ethernet and GPIB at 100,000 readings per second. Fast, high resolution data capture gives you the quantity and quality of information you need to make timely, correct decisions affecting system throughput and efficiency.

      • 0 ns to 100 s aperture setting allows industry’s widest flexibility to control data capture window
      • Reading speed: 1 reading /s @ 8.5 digits to 100,000 reading /s @ 4.5 digits
      • Data transfer from memory to PC: up to 500,000 readings /s in binary format through USB, up to 200,000 through Ethernet and GPIB

      Debug and perfect your device under test


      The 8558A features a 5 mega-sample digitizing rate with up to 20 MHz analog bandwidth, making it the first and only instrument on the market that can characterize extremely low level transient signals at 18-bit resolution. This capability makes it easier to debug designs, uncover anomalies and perfect your devices under test for use in real life environments.

      • Voltage sensitivity to hundreds of nV and current sensitivity to hundreds of pA allows you uncover ultra-low level transient signals
      • Up to 20 MHz bandwidth for voltage and 4 MHz for current retains high bandwidth content of the signal measured
      • 18-bit SAR analog-to-digital converter that achieves 5 mega-samples per second
      • 5 mega-samples per second sample rate, into buffer, for capturing complex, fast changing waveforms
      • 15 million readings memory allows large amount of data storage eliminating the
      • immediate need to transfer data to a PC
      • Graphical waveform display enables real-time visualization of complex waveforms, increased productivity with faster access to results and answers

      Fast, reliable and accurate system compatibility


      Inserting a new instrument into a tightly synchronized system can create overhead and incompatibility. The 8558A’s digital platform includes common connectivity interfaces plus precise triggering that lets it digitize, integrate and transfer data to anywhere in the system for analysis, with minimal obstruction and the highest reliability.

      • GPIB, USBTMC, Ethernet allows industry standard selection of remote interface
      • USB thumb drive enable quick and easy data transfer to PC in .csv format
      • SCPI compliant commands with 8505A and 3458A emulation mode simplifies and accelerates system upgrade process to 8588A/8558A
      • Fully supports MET/CAL calibration procedures library that commands the Fluke 8508A 
      • IVI Driver for industry standard control of DMM on 8558A/8588A
      • Trigger Mechanisms: External BNC Trigger Trig In and Trig Out, Edge or level trigger, Timer trigger, Epoch trigger, Line trigger
      • Less than 100 ns trigger latency with external BNC trigger for digitize voltage and current
      8558A 8.5 Digit Multimeter

      Analyze: FFT
       

      8558A 8.5 Digit Multimeter

      Trend Plot
       

      8558A 8.5 Digit Multimeter

      Trigger System
       

      Usability features ease training and operation


      Some popular system digit multimeters have complex menu structures and unintuitive commands, while others lack any user interface, presenting barriers to training and operation. By contrast, the 8558A features an easy-to-access configuration menu that makes it easy to train new users. Language choices include English, Chinese, French, German, Japanese, Korean, Russian and Spanish. The graphical display lets you easily visualize trends, histograms, complex waveforms, and statistics. Repeatable system-specific tasks can be automated quickly and easily.

      The 8558A’s front panel features Visual Connection Management™ output terminals that light up to show which terminals are active, guiding the user to make the correct connections. The handles and spin wheel are over-molded for comfort and easy transport.

      USB host ports are placed both on the front and rear of the unit. Use them to export data to external memory devices and simplify firmware updates.

      8558A 8.5 Digit Multimeter

      Trend Plot
       

      8558A 8.5 Digit Multimeter

      Analyze: Histogram
       

      The MET/CAL™ Calibration Management Software advantage


      The 8588A and 8558A work with Fluke Calibration MET/CAL™ Calibration Software with native MET/CAL support or using 8508A emulation mode to increase throughput up to four times that of traditional manual and multi-product methods while ensuring calibrations are performed consistently every time. This powerful software documents calibration procedures, processes and results for ease in complying with ISO 17025 and similar quality standards.

      Support and services when you need them


      Fluke Calibration offers testing, repair and calibration services to meet your needs quickly and at a fair cost while maintaining the high level of quality that you expect. Our electrical calibration laboratories are accredited for conformance to ISO/IEC Guide 17025 and we maintain global calibration and repair facilities.

      Get peace of mind and uptime with a Gold CarePlan service package


      The 8588A/8558A multimeters come with a standard one year factory warranty. You can enhance warranty protection with a Priority Gold Instrument CarePlan service package.

      A Priority Gold Instrument CarePlan includes an expedited annual calibration to reduce downtime by a week and extended warranty to help ensure the best long-term performance from your instruments. Choose from one-year, three-year or five-year Care- Plans. (Note: Priority shipping times vary by country. Contact your local Fluke Calibration sales representative for details.)

      Specifications: 8558A 8.5 Digit Multimeter

      8588A complete specifications
      8558A complete specifications

      Key feature and specification comparison8558A8588A
      DC voltage100 mV – 1000 V100 mV – 1000 V
      AC voltage10 mV – 1000 V, 1 Hz – 10 MHz10 mV – 1000 V, 1 Hz – 10 MHz
      Resistance, LoI, HV1 Ω - 10 GΩ1 Ω - 10 GΩ
      DC current10 uA – 2 A10 uA – 30 A
      AC current10 uA – 2A, 1 Hz to 100 kHz10 uA – 30 A, 1 Hz to 100 kHz
      Digitize V100 mV - 1000 V, 5 MSamples/s, up to 20 MHz BW100 mV - 1000 V, 5 MSamples/s, up to 20 MHz BW
      Digitize I10 uA - 2 A, 5 MSamples/s,
      up to 4 MHz BW
      10 uA - 30 A, 5 MSamples/s, up to 4 MHz BW
      Frequency (V, I, BNC)1 Hz to 10 MHz, 1 Hz to 100 kHz, 10 Hz to 100 MHz1 Hz to 10 MHz, 1 Hz to 100 kHz, 10 Hz to 100 MHz
      TemperaturePRT / Thermocouple (ext CJC)PRT / Thermocouple (ext CJC)
      CapacitanceNo1 nF – 100 mF
      RF powerNoR&S NRP Series
      Ext. dc current and ac currentNoA40B current shunt and other shunts
      Graphical displayYesYes
      Visual Connection Management ®YesYes
      Programmable front/rear input switchingYesYes
      Ratio difference, deviation - ohms, voltageYesYes
      External 10 MHz ref clock, 50 Î©/Hi-ZYesYes
      A40B and other shunt asset managementNoYes
      GPIB 488.2, Ethernet, USB TMCYesYes
      SCPI command compatibilityYesYes
      3458A emulation, 8508A emulationYesYes
      Memory15 million15 million
      Level and other triggerYesYes
      FFT onboardNoYes
      Reading rates: 5 MS/s into memory, bus: 100 kS/s at 4.5 digits, 1 rdg/s at 8.5 digitsYesYes

       

      Function8558A uX/X of reading + uX/X of range 8588A uX/X of reading + uX/X of range 
      95%99%95%99%
      DC voltage10 Vrelative4.0 + 0.065.2 + 0.082.7 + 0.053.5 + 0.06
      absolute4.1 + 0.065.3 + 0.082.8 + 0.053.6 + 0.06
      AC voltage10 V, 1 kHzrelative80 + 10103 + 1360 + 577 + 6.5
      absolute90 + 10116 + 1364 + 583 + 6.5
      Resistance10 kΩrelative10 + 0.613 + 0.77 + 0.59 + 0.6
      absolute10.3 + 0.613.3 + 0.77.2 + 0.59.2 + 0.6
      DC current1 mArelative9 + 512 + 66.5 + 48.4 + 5
      absolute9.8 + 513 + 67.6 + 410 + 5
      AC current1 mA, 1 kHzrelative300 + 100387 + 129250 + 50323 + 65
      absolute310 + 100400 + 129260 + 50335 + 65
      Frequency1 kHzrelativeN/AN/A0.50.5
      TemperaturePRT 100 Ωrelative± 5 mK± 5 mK± 5 mK± 5 mK
      Capacitance1 uFrelativeN/AN/A400 + 100516 + 129
      absoluteN/AN/A406 + 100523 + 129

      95% 1 year relative specification. Fluke Calibration guarantees to 99% confidence interval k=2.58. For 99%, multiply by (2.58/2)

      Looking for lower specs? See our other benchtop multimeters:

      Bench Multimeter Selection Guide
      ModelResolutionAccuracyApplication
      8588A8.52.7 µV/V 95% confidence level, 1 year relative accuracyMetrology
      8558A8.54.0 µV/V 95% confidence level, 1 year relative accuracyHigh-Speed Automation
      8845A/8846A6.5Basic V dc accuracy of up to 0.0024 %Bench
      8808A5.5Basic V dc accuracy of 0.015 %Bench

      Models: 8558A 8.5 Digit Multimeter

      8558A
      8.5 Digit Multimeter

      Buy it
      Includes:
      • Meter
      • 8588A-LEAD KIT-OSP General purpose probe kit & pouch with 2x 4-way shorting PCB
      8588A
      Reference Multimeter

      Buy it
      Includes:
      • Meter
      • 8588A-LEAD KIT-OSP General purpose probe kit & pouch with 2x 4-way shorting PCB
      • bvseo_sdk, p_sdk, 3.2.1
      • CLOUD, getContent, 22.49ms
      • QUESTIONS, PRODUCT
      • bvseo-msg: HTTP status code of 404 was returned;
      • bvseo_sdk, p_sdk, 3.2.1
      • CLOUD, getReviews, 24.8ms
      • REVIEWS, PRODUCT
      • bvseo-msg: HTTP status code of 404 was returned;
      Please enable cookies to view product reviews.