Key features

  • Two electrically isolated inputs
  • CAT III 1000 V / CAT IV 600 V safety rated
  • 200 MHz bandwidth model
  • 2.5 GS/s
  • Deep memory: 10,000 samples per channel waveform capture so you can zoom in on the details
  • Dedicated 5000 Count digital multimeter
  • IP-51 rated for dust and drip proof to withstand harsh environments
  • Easy-access battery door to make it easy to swap batteries
  • A handy slot to tether and lock down the oscilloscope while unattended using a standard Kensington® lock

Product overview: Fluke 190-204 ScopeMeter® Test Tool

Fluke 190-204 - 20 years of ScopeMeter® Test Tool Innovation

As the first four-channel portable scope safety rated CAT III 1000 V / CAT IV 600 V, the Fluke ScopeMeter® 190-204 combines an unprecedented level of performance, ruggedness, and portability with 200 MHz bandwidth and real-time sampling rates up to 2.5 GS/s and 200 ps resolution to capture noise and other disturbances. This model feature deep memory up to 10,000 samples per channel; so you can examine very small parts of the waveform in detail, and it is IP-51 rated to withstand dust, drips, humidity, and wide temperature variations. Fluke ScopeMeter® test tools are hand-held battery operated, designed to meet the demands of field service professionals.

Gain Four Times the Diagnostic Power Plus CAT IV Safety Rating

The Fluke ScopeMeter® 190-204 portable scope is double-insulated four-channel floating oscilloscopes safety rated for measurements in CAT III 1000V/CAT IV 600V environments.

Three-dimensional testing for industrial systems

Inspect input signals, output feedback loops or safety interlocks simultaneously to find a range of problems including:

  • Circuit voltage/current overloading
  • Signal timing measurements and synchronization issues
  • Attenuation/input impedance mismatch
  • Signal fluctuation/drift

Three-phase testing for diagnosing VSD, power inverters, and converters

  • Test for harmonics, transients and loads at the three-phase power input
  • Troubleshoot dc to ac converters for faulty IGBT gates or filter circuits
  • Test PWM output for reflections and transients or voltage unbalance

Safely measure from mV to kV

Standard probes that cover a wide application range from mV to kV prepare you for anything from micro-electronics to heavy duty medium voltage electrical applications. Independent isolated inputs eliminate the risk of accidental ground short circuits by allowing you to make measurements in mixed circuits with separate ground references.

Take on the Harshest Conditions with the only IP-51-rated Scope on the Market

Rugged and shock-proof, all ScopeMeter® portable oscilloscopes are built for harsh environments. Their sealed cases protect them from dust, water vapor, drips, humidity and airborne pollutants, ensuring reliable accurate performance every time you need them.

Built in multimeter to quickly and conveniently perform precise measurements

Built-in digital multimeter 4 channel model with isolated dual input scope and dedicated digital multimeter. Conveniently switch from waveform analysis to precise multimeter measurements using the built in 5000 count digital multimeter. Measurement functions include Vdc, Vac, Vac+dc, resistance, continuity and diode test. Measure current and temperature using suitable shunt, probe or adapter with wide range of scaling factors.

Work a Full Shift on a Single Charge

New high-performance batteries take advantage of Li-ion technology to keep you going strong for up to seven hours. And with the easy-access battery door you can make battery swaps fast.

Capture and Share Waveforms Easily with New USB connectivity

Two USB ports, electrically isolated from measurement input circuits offer you easy USB connectivity to a PC or USB memory devices. Store unlimited waveform, screen captures or instrument steups to a USB memory device. Connect to a PC USB interface to transfer and archive critical measurement data using FlukeView software for windows.

See a Stable Display Instantly with Connect-and-View&trade Triggering

Connect-and-View™ automatically sets up correct triggering by recognizing signal patterns. Without touching a button, you get a stable, reliable, and repeatable display of virtually any signal including motor drive and control signals. Expedites measuring several test-points in rapid succession.

Record Up to 48 Hours of High-Resolution Waveforms with ScopeRecord™

ScopeRecord memory stores up to 30,000 data points per channel, capturing intermittents and fast glitches. (Two sets of multiple-channel recordings can be stored for later analysis.)

  • Stores events like motion profiles, UPS, power supply, and motor start-ups
  • With the Stop-on-Trigger mode, the ScopeMeter® 190-204 automatically recognizes a power failure and stores the waveform data preceding it
  • With the waveform zoom (up to 100x) you can look at the smallest details, like individual power cycles

Record up to 22 days with TrendPlot™ paperless recorder to find intermittent faults

Intermittent faults can be caused by bad connections, dust, dirt, corrosion, or simply broken wiring or connectors. Line outages, sags, or starting and stopping a motor can also cause a machine to stop. The TrendPlot function in the Fluke ScopeMeter® test tool helps find those faults by:

  • Plotting minimum and maximum peak values and average over time up to 22 days
  • Plotting any combination of voltages, amps, temperature, frequency and phase for all four inputs, all with time and date stamp to pinpoint faults

Tektronix THS3000 Handheld Oscilloscope

The Tektronix THS3000 Handheld Oscilloscope has been discontinued, but customers can find a nearly identical replacement with the Fluke 190 ScopeMeter® Test Tool.

See how the models compare:

 THS3000 Fluke 190 ScopeMeter Feature / Capability Differences
PlatformThe Tektronix THS 3000 and Fluke 190 ScopeMeter Test Tool share the same electronics, with some feature differences highlighted below
Sampling size2.5 GS/s max real time sampling rate; 5 GS/s max sequential sampling rate2.5 GS/s max real time sampling rateReal time sampling rate to capture all the details for troubleshooting electronic circuits
Safety ratingCAT IIICAT IVFluke 190 Series II covers all application installations from CAT II to CATIV
IP rating according to IEC529IP 41IP 51Fluke 190 Series with IP51 rating is less susceptible to harm caused by environmental conditions no matter where it is used in a lab or the field
SoftwareOpenChoiceFlukeView®FlukeView® makes it easy to extract, analyze and document waveforms
Probe sizeLab sizeIndustrial sizeOptional Fluke VPS-510-x Probes offer same size and performance as standard lab grade scope probe

Specifications: Fluke 190-204 ScopeMeter® Test Tool

Specifications
Bandwidth200 MHz
Number of channels200 MHz: 4 channels
Real-time sample rate2.5 GS/s
Inputs4 scope plus DMM input
Independently floating isolated inputsUp to 1000 V CAT III/600 V CAT IV between inputs, references and ground
Timebase range2 ns - 2 min/div
Input sensitivity2 mV-100 V/div
Trigger typesConnect-and-View™, Free Run, Single Shot, Edge, Delay, Dual Slope, Video, Video Line, Selectable pulse width, N-Cycle
Trigger sourceAny scope input channel
Glitch capture8 ns
Scope measurementsCursor: 7
Automatic: 30
Maximum record lengthScopeRecord mode: 30,000 pts
Scope mode: 10,000 pts per input
PersistenceDigital persistence giving analog oscilloscope-like waveform decay
Waveform compareWaveform reference with automatic Pass/Fail testing
Environmental Specifications
Operating temperature0°C to 40°C Including Batteries
0°C to 50°C Excluding Batteries
Storage temperature-20°C to +60°C
Operating altitudeUp to 2,000 m (6666 ft) for CAT IV 600 V, CAT III 1000 V
Up to 3,000 m (10,000 ft) for CAT III 600 V, CAT II 1000 V
Safety Specifications
Electrical safety1,000V CAT III/600V CAT IV (EN61010-1)
Mechanical and General Specifications
Size270 x 190 x 70 mm
Weight2.2 kg
Warranty3-years on main instrument, 1-year on accessories
Li-Ion batteryBP291 4800 mAh battery up to 7 hours included standard
Included Accessories
 VPS410 Voltage Probe Sets (one red, one blue, one grey, one green)
BC190 Battery Charger/mains Adapter
BP291 4800 mAh high capacity Li-ion Battery
Handstrap (affixed to instrument)
Hangstrap
Multi-Language User Manuals on CD-Rom
FlukeView ScopeMeter® demo package (restricted functionality)
USB Interface Cable
WarrantyThree years on main instrument, one year on accessories

Models: Fluke 190-204 ScopeMeter® Test Tool

Fluke 190-204
Fluke 190-204 ScopeMeter® Test Tool

Buy it

Includes:

  • Color ScopeMeter® 200 MHz
  • 4 channels
  • DMM/Ext.input
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 22.81ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Rated 3 out of 5 by from Good Portable Scope We use this scope a good deal at work for troubleshooting various industrial automation applications - especially VFDs. The main benefit of this scope is the portability and the isolated inputs. It is rugged and well built. The highlights are: -A full featured scope in a portable package -Great bandwidth options and sufficient sampling rate -Isolated inputs -Decent battery life -Very rugged -Quality probes -Controls are pretty intuitive with good on-screen menus -Does 95% of what a bench scope can do for basic troubleshooting My main complaints are the following: -Screen resolution is pretty lousy, giving thick, aliased traces. Cursor measurement is a rough guess at best. -Built in measurement and software features are lacking compared to entry level bench scopes. The waveform math functions are especially limited. -The per channel memory sample memory is very lousy (10,000 pts). It is great that the scope can sample at 2.5Gs/s or more on some models, but with such small sample memory, you ability to capture non-recurrent events is very limited. I'd like to see this be in the >5Mpts range, especially since this product by design will be used to troubleshoot intermittent events. -The waveform persistence is nice, but does not employ variable brightness, so you end up with a smudge of a waveform. -A dark theme would be really nice. -PC software integration should be included in the purchase price at this price point -The screen should be glass, too easy to scratch when carrying around.
Date published: 2020-12-08
Rated 1 out of 5 by from Good Scope Great accuracy etc however they make you buy a license to use this on a PC after spending many thousands on the tool itself - you'd think that they would be kind enough to provide this for free like other companies do. 'Thanks again Fluke'.
Date published: 2018-01-23
Rated 1 out of 5 by from Not user friendly The device works great, however, in order to get drivers requires some digging and access to software for reports requires an activation key?!?! If I spend thousands of dollars on your device, why do I need an activation key??? Thanks for wasting peoples time Fluke.
Date published: 2017-11-02
Rated 4 out of 5 by from Good scope for field work and testing Light and easy to carry. Has 4 isolated channels. Good screen but lines are too thick. It does not remember the settings - new at using this scope so I may have missed some instructions. I will use for field work and on site commissioning. Will not use on bench in factory.
Date published: 2016-12-07
Rated 5 out of 5 by from Great Tool! Purchased tool few months ago and really enjoy how easy it is to use and the clarity of the screen! Having 4 channels really helps debug issues faster. So many features, recommend reading the user manual. Possible Improvements: The battery could last longer The carrying cases latches will not open without hitting it
Date published: 2016-12-07
  • y_2024, m_11, d_22, h_7
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_5
  • loc_en_US, sid_1627903328308, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 23.03ms
  • REVIEWS, PRODUCT
Please enable cookies to view product reviews.

Manuals + resources: Fluke 190-204 ScopeMeter® Test Tool