Fluke eMobility Tools Kit with FEV100 Test Adapter, 125B ScopeMeter®, 87V Multimeter and Test Leads

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 123.89ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • Fluke EV Kit 2 FEV100/TY1 KIT2
  • Fluke EV Kit 2 FEV100/TY1 KIT2
  • Fluke EV Kit 2 FEV100/TY1 KIT2
  • Fluke EV Kit 2 FEV100/TY1 KIT2
  • Fluke EV Kit 2 FEV100/TY1 KIT2

Key features

  • Test charging states of EVSE with CP state simulation with the 12B ScopeMeter®.
  • Verify charging voltage and maximum available current using the 87V multimeter and TL224 test leads.
  • Check protective earth for correct wiring and functioning with the PE pre-test feature. 
  • Perform GFCI troubleshooting of EVSE and verify operation within safety standards. 

Product overview: Fluke eMobility Tools Kit with FEV100 Test Adapter, 125B ScopeMeter®, 87V Multimeter and Test Leads

Test the safety and performance of a type 1, level 1 or level 2 electric vehicle ac charging stations (EVSEs) with the Fluke FEV100, 87V + 125B ScopeMeter® kit. This kit includes the FEV100 test adapter to simulates the presence of an electrical vehicle. When connected to the test adapter, the 87V multimeter will allow you to monitor the output voltage and maximum charging current of the station. Verify EVSE charging states (vehicle simulation) by connecting the 125B ScopeMeter® to measure the control pilot signal output. With this kit, it's easy to verify an EV charging station is working properly after install and during periodic maintenance, or troubleshoot an EVSE if it is not delivering the appropriate charge. SAE J1772 compliant to North American standards.

EVSE installation safety and performance checks

  • PE PRE-TEST: Grounding system pre-test verifies that there is no presence of dangerous voltage at the ground terminal​.
  • GFCI TEST: Ground fault circuit interrupter test verifies the breaker of the EVSE is connected by detecting ground faults​.
  • PE ERROR: Ground fault simulation indicates an interruption of the ground conductor; the pending charging process is aborted, and new charging processes are prevented.
  • CP ERROR “E”: The standard J1772 defines Error “E” as a state when charging station is disconnected from vehicle, disconnected from utility, there is a loss of utility power or control pilot is short to control pilot reference (ground).
 

Virtual demo

What's in the box:

FEV100
  • Fluke FEV100/BASIC Test Adapter
  • Fluke FEV-CON/TY1 Type 1 Connector & Cable
  • Soft Carrying Case
  • User Manual
  • 3-year warranty

125B
  • Fluke 125B Hand-Held Oscilloscope
  • Shielded Test Leads with Black Ground Leads
  • Test Lead Black (for Grounding)
  • Hook Clips (red, blue)
  • Banana-to-BNC Adapters (black, x1)
  • 10:1 Voltage Probe
  • i400s AC Current Clamp
  • USB Angled Adapter
  • WiFi USB Adapter
  • Switch Mode Power Supply, Adapter/Battery Charger
  • Rechargeable Li-ion Battery Pack

87V
  • Fluke 87V Industrial Multimeter
  • TL75 Test Leads (TL175 Eur)
  • AC175 Alligator Clips
  • Holster with tilt-leg, test lead storage
  • 80BK Temperature Probe
  • 9V Battery (Installed)

TL224
  • One pair (red, black) silicone insulated leads with one straight female coupler on one end and right angled on the other
  • One-year warranty
  • Quick Reference Guide

Specifications: Fluke eMobility Tools Kit with FEV100 Test Adapter, 125B ScopeMeter®, 87V Multimeter and Test Leads

Fluke FEV100 Electric Vehicle Charging Station Test Adapter specifications

Input voltageUL1/N = 120 V, UL2/N = 120 V, UL1/L2 = 208 V, 60 Hz (three-phase system) or UL1/N = 120 V, UL2/N = 120 V, UL1/L2 = 240 V, 60 Hz (single-phase system), ±10% voltage fluctuations from nominal
EV connector (EVC-13)SAE J1772 socket, 16 A (type 1, 5P single-phase)
Internal power consumption2 W max.
Operating temperature-4 °F to 104 °F (-20 °C to 40 °C)
Storage temperature-4 °F to 122 °F (-20 °C to 50 °C)
Operating humidity range10 % to 85 % relative humidity non-condensing
Storage relative humidity0 % to 85 % non-condensing
Operating altitude6561 ft (2000 m) max.
Dimensions (H × W × D)Approx. 8.66 x 4.33 x 1.77 in (220 x 110 × 45 mm) without cable assembly
WeightApprox. 4.4 lb (2 kg)
Safety standardsIEC 61010-1, Pollution Degree 2
IEC 61010-2-030
Measurement categoryCAT II 250 V
IP protection classIP54
Electromagnetic Compatibility (EMC)
InternationalIEC 61326-1: Basic Electromagnetic Environment
CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
USA (FCC)47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Functions
CP StatesA, B, C, D
CP Error “E”On/off
PE ErrorOn/off
GFCI TestYes, test resistor of 2 kΩ connected between L1 and PE, time limitation 40 ms
PE Pre-Test (typical)Visible indication >30 V on PE conductor
Outputs (for test purpose only)
Measuring terminals
L1, L2/N, PE
Max. 250 V 50/60 Hz, CAT II 250 V
CP signal output terminalsApprox. ±12 V (under normal conditions), in case of wrong wiring or error of the charging station these terminals can be hazardous ≥ max. 250 V against PE
 

Fluke 120B Series Industrial ScopeMeter® Hand-Held Oscilloscopes Specification: Oscilloscope mode

Vertical
Frequency response - dc coupledWithout probes and test leads (with BB120)123B: dc to 20 MHz (-3 dB)
124B and 125B: dc to 40 MHz (-3 dB)
With STL120-IV 1:1 shielded test leadsDC to 12.5 MHz (-3 dB) / dc to 20 MHz (-6 dB)
With VP41 10:1 Probe123B: dc to 20MHz (-3 dB)
124B and 125B: dc to 40 MHz (-3 dB)
Frequency response - ac coupled (lf roll off)Without probes and test leads<10 Hz (-3 dB)
With STL120-IV 1:1 shielded test leads<10 Hz (-3 dB)
With VP41 10:1 Probe<10 Hz (-3 dB)
Rise time, excluding probes, 
test leads
123B <17.5 ns
124B and 125B <8.75 ns
Input impedanceWithout probes and test leads1 MΩ//20 pF
With BB1201 MΩ//24 pF
With STL120-IV 1:1 shielded test leads1 MΩ//230 pF
With VP41 10:1 Probe5 MΩ//15.5 pF
Sensitivity5 mV to 200 V/div
Analog bandwidth limiter10 kHz
Display modesA, -A, B, -B
Max. input voltage A and BDirect, with test leads, or with VP41 Probe600 Vrms Cat IV, 750 Vrms maximum voltage.
With BB120600 Vrms
Max. floating voltage, from any terminal to ground600 Vrms Cat IV, 750 Vrms up to 400Hz
Horizontal
Scope modesNormal, Single, Roll
Ranges (normal)Equivalent sampling123B: 20 ns to 500 ns/div,
124B and 125B: 10 ns to 500 ns/div
Real time sampling1 μs to 5 s/div
Single (real time)1 μs to 5 s/div
Roll (real time)1s to 60 s/div
Sampling rate (for both channels simultaneously)Equivalent sampling (repetitive signals)Up to 4 GS/s
Real time sampling 1 μs to 60 s/div40 MS/s
 
Trigger
Screen updateFree run, on trigger
SourceA, B
Sensitivity A and B@ DC to 5 MHz0.5 divisions or 5 mV
@ 40 MHz123B: 4 divisions
124B and 125B: 1.5 divisions
@ 60 MHz123B: N/A
124B and 125B: 4 divisions
SlopePositive, negative
 
Advanced scope functions
Display modesNormalCaptures up to 25 ns glitches and displays analog-like persistence waveform
SmoothSuppresses noise from a waveform
Glitch offDoes not capture glitches between samples
EnvelopeRecords and displays the minimum and maximum of waveforms over time
Auto set (Connect-and-View™)Continuous fully automatic adjustments of amplitude, time base, trigger levels, trigger gap, and hold-off. Manual override by user adjustment of amplitude, time base, or trigger level.
 
Dual input meter
The accuracy of all measurements is within ±(% of reading + number of counts) from 18 °C to 28 °C.
Add 0.1x (specific accuracy) for each °C below 18 °C or above 28 °C. For voltage measurements with 10:1 probe, add probe  uncertainty +1%. More than one waveform period must be visible on the screen.
 
Input A and input B
DC voltage (VDC)
Ranges500 mV, 5 V, 50 V, 500 V, 750 V
Accuracy±(0.5% +5 counts)
Common mode rejection (CMRR)>100 dB @ dc, >60 dB @ 50, 60, or 400 Hz
Full scale reading5000 counts
True-rms voltages (V ac and V ac+dc)
Ranges500 mV, 5 V, 50 V, 500 V, 750 V
Accuracy for 5% to 100% of range (DC coupled)DC to 60 Hz (V ac+dc)±(1% +10 counts)
1 Hz to 60 Hz (V ac)±(1% +10 counts)
Accuracy for 5% to 100% of range (AC or dc coupled)60 Hz to 20 kHz±(2.5% +15 counts)
DC rejection (only VAC)>50 dB
Common mode rejection (CMRR)>100 dB @ dc
>60 dB @ 50, 60, or 400 Hz
Full scale reading5000 counts, reading is independent of any signal crest factor.
Peak
ModesMax peak, Min peak, or pk-to-pk
Ranges500 mV, 5 V, 50 V, 500 V, 2200 V
AccuracyAccuracy Max peak or Min peak5% of full scale
Accuracy Peak-to-Peak10% of full scale
Full scale reading500 counts
Frequency (Hz)
Ranges123B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz,1 MHz, 10 MHz, and 50 MHz
124B and 125B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz, 1 MHz, 10 MHz, and 70 MHz
Frequency range15 Hz (1 Hz) to 50 MHz in continuous autoset
Accuracy @1 Hz to 1 MHz±(0.5% +2 counts)
Full scale reading10,000 counts
RPM
Max reading50.00 kRPM
Accuracy±(0.5% +2 counts)
Duty cycle (PULSE)
Range2% to 98%
Frequency range15 Hz (1 Hz) to 30 MHz in continuous autoset
Pulse width (PULSE)
Frequency range15 Hz (1 Hz) to 30 MHz in continuous autoset
Full scale reading1000 counts
Amperes (AMP)
With current clampRangesSame as V dc, V ac, V ac+dc, or PEAK
Scale factors0.1 mV/A, 1 mV/A, 10 mV/A, 100 mV/A, 400 mV/A, 1 V/A, 10 mV/mA
AccuracySame as V dc, V ac, V ac+dc, or PEAK (add current clamp uncertainty)
Temperature (TEMP) with optional temperature probe
Range200 °C/div (200 °F/div)
Scale factor1 mV/°C and 1 mV/°F
AccuracyAs V dc (add temp. probe uncertainty)
Decibel (dB)
0 dBV1 V
0 dBm (600 Ω /50 Ω)1 mW referenced to 600 Ω or 50 Ω
dB onV dc, V ac, or Vac+dc
Full scale reading1000 counts
Crest factor (CREST)
Range1 to 10
Full scale reading90 Counts
Phase
ModesA to B, B to A
Range0 to 359 degrees
Resolution1 degree
Power (125B only)
Configurations1 phase / 3 phase 3 conductor balanced loads (3 phase: fundamental component only, AUTOSET mode only)
Power factor (PF)Ratio between watts and VA range - 0.00 to 1.00
WattRMS reading of multiplying corresponding samples of input A (volts) and input B (amperes)
Full scale reading999 counts
VAVrms x Arms
Full scale reading999 counts
VA reactive (var)√((VA)2-W2)
Full scale reading999 counts
Vpwm
PurposeTo measure on pulse width modulated signals, like motor drive inverter outputs
PrincipleReadings show the effective voltage based on the average value of samples over a whole number of periods of the fundamental frequency
AccuracyAs Vrms for sinewave signals
 
Input A to common
Ohm (Ω)
Ranges123B and 124B500 Ω , 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ
125B50 Ω, 500 Ω , 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ
Accuracy±(0.6% + 5 counts) 50 Ω ±(2% + 20 counts)
Full scale reading50 Ω to 5 MΩ - 5000 counts, 30 MΩ - 3000 counts
Measurement current0.5 mA to 50 nA, decreases with increasing ranges
Open circuit voltage<4 V
Continuity (Cont)
Beep<(30 Ω ±5 Ω) in 50 Ω range
Measurement current0.5 mA
Detection of shorts of≥1 ms
Diode
Measurement voltage@0.5 mA>2.8 V
@open circuit<4 V
Measurement current0.5 mA
Polarity+ on input A, - on COM
Capacitance (CAP)
Ranges50 nF, 500 nF, 5 μF, 50 μF, 500 μF
Full scale reading5000 counts
Measurement current500 nA to 0.5 mA, increases with increasing ranges
 
Advanced meter functions
Zero SetSet actual value to reference
AutoHold (on A)Captures and freezes a stable measurement result. Beeps when stable. AutoHold works on the main meter reading, with thresholds of 1 Vpp for AC signals and 100 mV for DC signals.
Fixed decimal pointActivated by using attenuation keys
 
Cursor Readout (124B and 125B)
SourcesA, B
Single vertical lineAverage, min and max readout
Average, min, max and time from start of readout (in ROLL mode; instrument in HOLD)
Min, max and time from start of readout (in RECORDER mode; instrument in HOLD)
Harmonics values in POWER QUALITY mode.
Dual vertical linesPeak-peak, time distance and reciprocal time distance readout
Average, min, max and time distance readout (in ROLL mode; instrument in HOLD)
Dual horizontal linesHigh, low and peak-peak readout
Rise or fall timeTransition time, 0%-level and 100%-level readout (manual or auto leveling; auto leveling only 
possible in single channel mode)
AccuracyAs oscilloscope accuracy
 
Recorder
The recorder captures meter readings in Meter Recorder mode or continuously captures waveform samples in Scope Recorder mode. The information is stored on internal memory or on optional SD card (with the 125B or 124B).
The results are displayed as Chart recorder display that plots a graph of min and max values of Meter measurements over time or as a waveform recorder display that plots all the captured samples.
Meter readings
Measurement SpeedMaximum 2 measurement/s
Record Size (min, max, average)2 M readings for 1 channel
Recorded Time Span2 weeks
Maximum number of events1024
Waveform record
Maximum sample rate400 K sample/s
Size Internal memory400 M samples Recorded Time
Span internal memory15 minutes at 500 μs/div
11 hours at 20 ms/div
Record Size SD card1.5 G samples
Recorded Time Span SD card11 hours at 500 μs/div
14 days at 20 ms/div
Maximum number of events64
 
Power Quality (125B only)
ReadingsWatt, VA, var, PF, DPF, Hz
Watt, VA, var ranges (auto)250 W to 250 MW, 625 MW, 1.56 GW
When selected: total (% r)±(2% + 6 counts)
When selected: fundamental (% f)±(4% + 4 counts)
DPF0.00 to 1.00
PF0.00 to 1.00, ±0.04
Frequency range10.0 Hz to 15.0 kHz
40.0 Hz to 70.0 Hz
Number of HarmonicsDC to 51
Readings / Cursor readings 
(fundamental 40 Hz to 70 Hz)
Vrms / Arms /WattEach harmonic from fundamental maybe selected for individual readings
Includes frequency of fundamental, phase Angle and K-factor (in Amp and Watt)
 
BusHealth tester (Fluke 125B only)
TypeSubtypeProtocol
AS-iNEN-EN50295
CANISO-11898
Interbus SRS-422EIA-422
ModbusRS-232RS-232/EIA-232
RS-485RS-485/EIA-485
Foundation FieldbusH161158 type 1, 31.25 kBit
ProfibusDPEIA-485
PA61158 type 1
 
Miscellaneous
DisplayType5.7-inch color active matrix TFT
Resolution640 x 480 pixels
Waveform DisplayVertical10 div of 40 pixels
Horizontal12 div of 40 pixels
PowerExternalVia Power Adapter BC430
Input voltage10 V DC to 21 V DC
Power consumption5 W typical
Input connector5 mm jack
InternalVia Battery Pack BP290
Battery powerRechargeable Li-Ion 10.8 V
Operating time7 hours with 50% backlight brightness
Charging time4 hours with test tool off,  7 hours with test tool on
Allowable ambient temp0 to 40 °C (32 to 104 °F) during charging
MemoryInternal memory can store 20 data sets  (screen waveform and setup)Micro SD card slot with optional SD card  (max size of 32 GB)
MechanicalSize259 x 132 x 55 mm 
(10.2 x 5.2 x 2.15 in)
Weight1.4 kg (3.2 lb) including battery pack
InterfaceOptically isolatedTransfer screen copies (bitmaps), settings and data
USB to PC/laptopOC4USB optically isolated USB adapter/cable, (optional), using FlukeView® software for Windows®.
Optional WiFi adapterFast transfer of screen copies (bitmaps), settings and data to PC/laptop, tablet, smartphone, etc. A USB port is provided for attaching the WiFi dongle. Do not use the USB port with a cable for safety reasons.
Environmental
EnvironmentalMIL-PRF-28800F, Class 2
TemperatureBattery Operation0 to 40 °C (32 to 104 °F)
Power Adapter Operation0 to 50 °C (32 to 122 °F)
Storage-20 to 60 °C (-4 to 140 °F)
Humidity (Operating)@ 0 to 10 °C (32 to 50 °F)Non-condensing
@ 10 to 30 °C (50 to 86 °F)95%
@ 30 to 40 °C (86 to 104 °F)75%
@ 40 to 50 °C (104 to 122 °F)45%
Storage@ -20 to 60 °C (-4 to 140 °F)Non-condensing
AltitudeOperating at 3 km (10,000 feet)CAT III 600 V
Operating at 2 km (6,600 feet)CAT IV 600 V
Storage12 km (40,000 feet)
EMC electromagnetic compatibilityInternationalIEC 61326-1: Industrial, CISPR 11:  Group 1, Class A
Korea (KCC)Class A Equipment (Industrial Broadcasting & Communication Equipment)
USA (FCC)47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Wireless radio with adapterFrequency range2412 MHz to 2462 MHz
Output power<100 mW
Enclosure protectionIP51, ref: EN/IEC60529
SafetyGeneralIEC 61010-1: Pollution Degree 2
MeasurementIEC 61010-2-033: CAT IV 600 V/CAT III 750 V
Max. input voltage input A and BDirect on input or with leads600 Vrms CAT IV for derating
With Banana-to-BNC Adapter BB120600 Vrms for derating
Max. floating voltage from any terminal to ground600 Vrms Cat IV, 750 Vrms up to 400 Hz
 

Fluke 87V Industrial Multimeter Specifications

Voltage DCMaximum voltage1000 V
Accuracy±(0.05% + 1)
Maximum resolution10 µV
Voltage ACMaximum voltage1000 V
Accuracy±(0.7% + 2) True RMS
AC bandwidth20 kHz with low pass filter; 3 dB @ 1 kHz
Maximum resolution0.1 mV
Current DCMaximum amps10 A (20 A for 30 seconds maximum)
Amps accuracy±(0.2% + 2)
Maximum resolution0.01 µA
Current ACMaximum amps10 A (20 A for 30 seconds maximum)
Amps accuracy±(1.0% + 2) True RMS
Maximum resolution0.1 µA
ResistanceMaximum resistance50 MΩ
Accuracy±(0.2% + 1)
Maximum resolution0.1 Ω
CapacitanceMaximum capacitance9,999 µF
accuracy±(1% + 2)
Maximum resolution0.01 nF
FrequencyMaximum frequency200 kHz
Accuracy±(0.005% + 1)
Maximum resolution0.01 Hz
Duty cycleMaximum duty cycle99.9%
Accuracy±(0.2% per kHz + 0.1%)
Maximum resolution0.1%
Temperature measurement–200.0 °C – 1090 °C
–328.0 °F – 1994.0 °F
excluding probe
80 BK temperature probe–40.0 °C – 260 °C
–40.0 °F – 500 °F, 2.2 °C or 2% whichever is greater
ConductanceMaximum conductance60.00 nS
Accuracy±(1.0% + 10)
Maximum resolution0.01 nS
DiodeRange3 V
Resolution1 mV
Accuracy±(2% + 1)
Duty cycle rangeAccuracyWithin ±(0.2% per kHz + 0.1%)
Environmental Specifications
Operating temperature–20 °C to + 55 °C
Storage temperature–40 °C to + 60 °C
Humidity (without condensation)0% – 90% (0 °C – 35 °C)
0% – 70% (35 °C – 55 °C)
Operating Altitude2000 m
Safety Specifications
Overvoltage categoryEN 61010–1 to 1000 V CAT III, 600V CAT IV
Agency approvalsCE, CSA, RCM
Mechanical and General Specifications
Size201 x 98 x 52 mm (with holster)
Weight355 g
624 g – with holster
DisplayDigital6000 counts updates 4/sec.
19,999 counts in high–resolution mode
Analog32 segments, updates 40/sec
Frequency19,999 counts, updates 3/sec at > 10 Hz
WarrantyLifetime
Battery LifeAlkaline~400 hours typical, without backlight
Shock1 Meter drop per IEC 61010–1:2001
VibrationPer MIL–PRF–28800 for a Class 2 instrument

Models: Fluke eMobility Tools Kit with FEV100 Test Adapter, 125B ScopeMeter®, 87V Multimeter and Test Leads

FLK-FEV100/TY1 KIT2

Buy it
Includes:

FEV100
  • Fluke FEV100/BASIC Test Adapter
  • Fluke FEV-CON/TY1 Type 1 Connector & Cable
  • Soft Carrying Case
  • User Manual
  • 3-year warranty

125B
  • Fluke 125B Hand-Held Oscilloscope
  • Shielded Test Leads with Black Ground Leads
  • Test Lead Black (for Grounding)
  • Hook Clips (red, blue)
  • Banana-to-BNC Adapters (black, x1)
  • 10:1 Voltage Probe
  • i400s AC Current Clamp
  • USB Angled Adapter
  • WiFi USB Adapter
  • Switch Mode Power Supply, Adapter/Battery Charger
  • Rechargeable Li-ion Battery Pack

87V
  • Fluke 87V Industrial Multimeter
  • TL75 Test Leads (TL175 Eur)
  • AC175 Alligator Clips
  • Holster with tilt-leg, test lead storage
  • 80BK Temperature Probe
  • 9V Battery (Installed)

TL224
  • One pair (red, black) silicone insulated leads with one straight female coupler on one end and right angled on the other
  • One-year warranty
  • Quick Reference Guide
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 50.47ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 22.8ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.

Manuals + resources: Fluke eMobility Tools Kit with FEV100 Test Adapter, 125B ScopeMeter®, 87V Multimeter and Test Leads