Key features

  • Measure safely with CAT III 1500 V rated clamp meter
  • Thin jaw for access to cables in crowded combiner boxes
  • Work efficiently with dc power measurement, audio polarity and visual continuity
  • Measure solar irradiance, ambient and PV module temperature, array orientation and tilt angles
  • Solar PV test lead sets are designed for use with solar clamp meters that accept 4mm banana plugs, rated to CAT III 1000 V / CAT IV 600 V

Product overview: Solar Tools Kit with 393 FC Clamp Meter, Irradiance Meter and Solar Test Leads

The 393 FC CAT III 1500 V True-rms Clamp Meter with iFlex is an industrial clamp meter designed for solar photovoltaic (PV) installation technicians and maintenance professionals who work in high voltage dc environments. Safely connect the Solar PV test leads to the clamp meter to validate voltage and current from individual panels or a series of panels in a PV array. The inline capabilities of the Solar PV PVLEAD3 leads allow the system to remain online and generating power while testing without needing to pierce the line. Use the IRR1-SOL to obtain the amount of solar irradiance necessary to calculate the IV curve of the power output. Validate that the panel or string of panels are outputting the correct voltage.

Key functions of the solar clamp meter, irradiance meter and Solar PV test leads:

  • View voltage and current simultaneously with the meter's dual display
  • IP54 rated meter, ideal for work outdoors including PV panel testing
  • DC power measurement, showing readings in kVA
  • Logging and reporting of test results via Fluke Connect software
  • Make instantaneous measurements to determine the watts per square meter solar irradiation, required by IEC 62446-1 standard
  • Solar PV leads comply to IEC / EN 61010-031

The world's first CAT III 1500 V true-RMS solar clamp meter

 

Fluke IRR1-SOL Irradiance Meter


 

What's in the box:

  • Fluke 393 FC CAT III 1500 V TRMS clamp meter
  • Test leads, CAT III 1500 V rated, right angle plugs, with safety caps
  • iFlex 18 inch flexible current probe
  • TPAK magnetic hanging strap
  • Premium carrying case
  • 3-year warranty
  • FLK-IRR1-SOL Solar Irradiance Meter
  • FLK80PR-IRR External Temperature Probe with Suction Cup
  • C250 Carrying Case with Shoulder Strap
  • (4) AA Alkaline Batteries (installed)
  • User Manual
  • Pomona PVLEAD1 Solar PV Connector to 4 mm Test Lead Set
  • Pomona PVLEAD3 Solar PV Clamp Test Lead Set

Specifications: Solar Tools Kit with 393 FC Clamp Meter, Irradiance Meter and Solar Test Leads


Specifications: Fluke 393 FC CAT III 1500 V True-rms Solar Clamp Meter

General   
Maximum voltage between any Terminal and Earth Ground  
AC1000 V  
DC1500 V  
Batteries2 AA IEC LR6 alkaline  
DisplayDual display with backlight  
Automatic Power Off20 minutes  
Electrical   
Accuracy   
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits]).
Temperature CoefficientsAdd 0.1 x specified accuracy for each °C > 28 °C or < 18 °C
AC Current: Jaw   
Range999.9 A  
Resolution0.1 A  
Accuracy2 % + 5 digits (10 Hz to 100 Hz) 
 2.5 % + 5 digits (100 Hz to 500 Hz) 
Crest Factor (50/60 Hz)2.5 @600.0 A  
 3.0 @500.0 A  
 1.42 @999.9 A  
 Add 2 % for C.F. >2  
AC Current: Flexible Current Probe   
Range999.9 A  
 2500 A  
Resolution0.1 A (≤999.9 A)  
 1 A (≤2500 A)  
Accuracy3 % RD + 5 digits (10 Hz to 500 Hz) 
Crest Factor (50/60Hz)2.5 @1400 A  
 3.0 @1100 A  
 1.42@2500 A  
 Add 2 % for C.F. >2  
Position Sensitivity   
NEC symbol
Distance from Optimumi2500-10 Flexi2500-18 FlexError
A0.5 in (12.7 mm)1.4 in (35.6 mm)±0.5 %
B0.8 in (20.3 mm)2.0 in (50.8 mm)±1.0 %
C1.4 in (35.6 mm)2.5 in (63.5 mm)±2.0 %
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
    
DC Current   
Range999.9 A  
Resolution0.1 A  
Accuracy2 % RD + 5 digits[1]  
 [1] When using the ZERO (B) function to compensate for offsets.
AC Voltage   
Range600.0 V  
 1000 V  
Resolution0.1 V (≤600.0 V)  
 1 V (≤1000 V)  
Accuracy1 % RD + 5 digits (20 Hz to 500 Hz) 
DC Voltage   
Range600.0 V  
 1500 V  
Resolution0.1 V (≤600.0 V)  
 1 V (≤1500 V)  
Accuracy1 % RD + 5 digits  
mV dc   
Range500.0 mV  
Resolution0.1 mV  
Accuracy1 % RD + 5 digits  
Amps Frequency: Jaw   
Range5.0 Hz to 500.0 Hz  
Resolution0.1 Hz  
Accuracy0.5 % RD + 5 digits  
Trigger Level5 Hz to 10 Hz, ≥10 A  
 10 Hz to 100 Hz, ≥5 A  
 100 Hz to 500 Hz, ≥10 A  
Amps Frequency: Flexible Current Probe   
Range5.0 Hz to 500.0 Hz  
Resolution0.1 Hz  
Accuracy0.5 % RD + 5 digits  
Trigger Level5 Hz to 20 Hz, ≥25 A  
 20 Hz to 100 Hz, ≥20 A  
 100 Hz to 500 Hz, ≥25 A  
Voltage Frequency   
Range5.0 Hz to 500.0 Hz  
Resolution0.1 Hz  
Accuracy0.5 % RD + 5 digits  
Trigger Level5 Hz to 20 Hz, ≥5 V  
 20 Hz to 100 Hz, ≥5 V  
 100 Hz to 500 Hz, ≥10 V  
DC Power   
Range600.0 kVA (600.0 V dc range)  
 1500 kVA (1500 V dc range)  
Resolution0.1 kVA  
 1 kVA  
Accuracy2 % RD + 2.0 kVA  
 2 % RD + 20 kVA  
Resistance   
Range600.0 Ω  
 6000 Ω  
 60.00 kΩ  
Resolution0.1 Ω (≤600.0 Ω)  
 1 Ω (≤6000 Ω)  
 0.01 kΩ (≤60.00 kΩ)  
Accuracy1 % RD + 5 digits  
Capacitance   
Range100.0 μF  
 1000 μF  
Resolution0.1 μF (≤100.0 μF)  
 1 μF (≤1000 μF)  
Accuracy1 % RD + 5 digits  
Inrush Trigger Level5 A  
Mechanical   
Size (L x W x H)281 mm x 84 mm x 49 mm  
Weight (with batteries)520 g  
Jaw Opening34 mm  
Flexible Current Probe Diameter7.5 mm  
Flexible Current Probe Cable Length   
(head to electronics connector)1.8 m  
Environmental   
Operating Temperature-10 °C to 50 °C  
Storage Temperature-40 °C to 60 °C  
Operating HumidityNon condensing (<10°C)  
 ≤90 % RH (at 10 °C to 30 °C)  
 ≤75 % RH (at 30 °C to 40 °C)  
 ≤45 % RH (at 40 °C to 50 °C)  
Operating Altitude2000 m  
Storage Altitude12 000 m  
Ingress Protection (IP) RatingIEC 60529: IP54 non-operating  
Electromagnetic Compatibility (EMC)   
InternationalIEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A
 Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
Korea (KCC)Class A equipment (Industrial Broadcast & Communications Equipment)
 Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC)47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Safety   
GeneralIEC 61010-1, Pollution Degree 2 
MeasurementIEC 61010-2-032: CAT III 1500 V / CAT IV 600 V 
 IEC 61010-2-033: CAT III 1500 V / CAT IV 600 V 
Wireless Radio   
Radio frequency certificationFCC ID: T68-FBLE, IC: 6627A-FBLE 
Wireless Radio Frequency Range2400 MHz to 2483.5 MHz  
Output Power<100 mW  
SIMPLIFIED EU DECLARATION OF CONFORMITY  
Hereby, Fluke declares that the radio equipment contained in this Product is in compliance with Directive 2014/53/EU.
The full text of the EU declaration is available at the following Internet address:  
www.fluke.com/en-us/declaration-of-conformity   
 

Specifications: Fluke Solar Irradiance Meter

Irradiance
Measuring Range0 to 1400 W/m²
Resolution1 W/m²
Measuring Accuracy± (5 % + 5 Digit)
Temperature Measurement
Measuring range (°C)-22 °F to 212 °F (-30 °C to 100 °C)
Resolution0.2 °F (0.1 °C) / 1 °F @>100 °F
Measuring Accuracy±2 °F (±1 °C) @ 14 °F to 167 °F (-10 °C to 75 °C),
±4 °F (±2 °C) @ -22 °F to 14 °F (-30 °C to -10 °C) and 167 °F to 212 °F (75 °C to 100 °C)
Note: Temperature measurement response time: ~30 sec.
Inclination Angle
Measuring Range-90° to +90°
Resolution0.1°
Measuring Accuracy± 1.5°@ -50° to +50°, ±2.5° @ -85° to -50° and +50° to +85°, ±3.5° @ -90° to -85° and +85° to +90°
Compass
Measuring Range0° to 360°
Resolution
Measuring Accuracy±7°
Note:
a) Measurements valid for device inclination between -20° and +20° to horizontal. Outside that range on LCD will be shown "---".
b) Result is referred to magnetic north.
Temperature
Operating Temperature IRR1-SOL-20 °C to 50 °C (humidity <80%), noncondensing
Operating Temperature 80PR-IRR-30 °C to +100 °C
Storage Temperature-30 °C to 60 °C (humidity <80%)
Altitude0 m to max. 2000 m
Electromagnetic Compatibility (EMC)
InternationalIEC 61326-1: Portable Electromagnetic Environment
CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for radio frequency energy that is necessary for the internal function of the equipment itself. Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
Korea (KCC)Class A Equipment (Industrial Broadcasting & Communication Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC)47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Protection
IP ProtectionIP40
Power Supply & Battery Life
Batteries4 AA Alkaline Batteries
Battery Life (typical)50 hours (≤9000 readings)
Auto Power Off30 minutes
Dimensions
L x W x H5.90 x 3.14 x 1.37 in (150 x 80 x 35 mm)
Weight0.5 lb (231 g)


Specifications: Pomona PVLEAD1 and PVLEAD3 Solar PV Clamp Test Lead Set

 PVLEAD1PVLEAD3
Solar PV Connector to 4mm Test Lead SetSolar PV Clamp Test Lead Set
ContactBrass, Nickel PlatedBrass, Nickel Plated
Length60”36”, 12”
VoltageCAT III 1000V,CAT III 1000V,
CAT IV 600VCAT IV 600V
Current20 amp20 amp
StandardsIEC 61010-031IEC 61010-031
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 123.59ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 23.8ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.