      Key features

      Read more

      Product overview: Solar Tools Kit with 393 FC Clamp Meter and Solar Test Leads

      The 393 FC CAT III 1500 V True-rms Clamp Meter with iFlex is an industrial clamp meter designed for solar photovoltaic (PV) installation technicians and maintenance professionals who work in high voltage dc environments. Safely connect the Solar PV test leads to the clamp meter to validate voltage and current from individual panels or a series of panels in a PV array. The inline capabilities of the Solar PV PVLEAD3 leads allow the system to remain online and generating power while testing without needing to pierce the line.

      Key functions of the solar clamp meter and Solar PV test leads:

      • View voltage and current simultaneously with the meter's dual display
      • IP54 rated meter, ideal for work outdoors including PV panel testing
      • DC power measurement, showing readings in kVA
      • Logging and reporting of test results via Fluke Connect software
      • Solar PV leads comply to IEC / EN 61010-031

      The world's first CAT III 1500 V true-RMS solar clamp meter

       

      What's in the box:

      • Fluke 393 FC CAT III 1500 V TRMS clamp meter
      • Test leads, CAT III 1500 V rated, right angle plugs, with safety caps
      • iFlex 18 inch flexible current probe
      • TPAK magnetic hanging strap
      • Premium carrying case
      • 3-year warranty
      • Pomona PVLEAD1 Solar PV Connector to 4 mm Test Lead Set
      • Pomona PVLEAD3 Solar PV Solar Clamp Test Lead Set

      Specifications: Solar Tools Kit with 393 FC Clamp Meter and Solar Test Leads


      Specifications: Fluke 393 FC CAT III 1500 V True-rms Solar Clamp Meter

      General   
      Maximum voltage between any Terminal and Earth Ground  
      AC1000 V  
      DC1500 V  
      Batteries2 AA IEC LR6 alkaline  
      DisplayDual display with backlight  
      Automatic Power Off20 minutes  
      Electrical   
      Accuracy   
      Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits]).
      Temperature CoefficientsAdd 0.1 x specified accuracy for each °C > 28 °C or < 18 °C
      AC Current: Jaw   
      Range999.9 A  
      Resolution0.1 A  
      Accuracy2 % + 5 digits (10 Hz to 100 Hz) 
       2.5 % + 5 digits (100 Hz to 500 Hz) 
      Crest Factor (50/60 Hz)2.5 @600.0 A  
       3.0 @500.0 A  
       1.42 @999.9 A  
       Add 2 % for C.F. >2  
      AC Current: Flexible Current Probe   
      Range999.9 A  
       2500 A  
      Resolution0.1 A (≤999.9 A)  
       1 A (≤2500 A)  
      Accuracy3 % RD + 5 digits (10 Hz to 500 Hz) 
      Crest Factor (50/60Hz)2.5 @1400 A  
       3.0 @1100 A  
       1.42@2500 A  
       Add 2 % for C.F. >2  
      Position Sensitivity   
      NEC symbol
      Distance from Optimumi2500-10 Flexi2500-18 FlexError
      A0.5 in (12.7 mm)1.4 in (35.6 mm)±0.5 %
      B0.8 in (20.3 mm)2.0 in (50.8 mm)±1.0 %
      C1.4 in (35.6 mm)2.5 in (63.5 mm)±2.0 %
      Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
          
      DC Current   
      Range999.9 A  
      Resolution0.1 A  
      Accuracy2 % RD + 5 digits[1]  
       [1] When using the ZERO (B) function to compensate for offsets.
      AC Voltage   
      Range600.0 V  
       1000 V  
      Resolution0.1 V (≤600.0 V)  
       1 V (≤1000 V)  
      Accuracy1 % RD + 5 digits (20 Hz to 500 Hz) 
      DC Voltage   
      Range600.0 V  
       1500 V  
      Resolution0.1 V (≤600.0 V)  
       1 V (≤1500 V)  
      Accuracy1 % RD + 5 digits  
      mV dc   
      Range500.0 mV  
      Resolution0.1 mV  
      Accuracy1 % RD + 5 digits  
      Amps Frequency: Jaw   
      Range5.0 Hz to 500.0 Hz  
      Resolution0.1 Hz  
      Accuracy0.5 % RD + 5 digits  
      Trigger Level5 Hz to 10 Hz, ≥10 A  
       10 Hz to 100 Hz, ≥5 A  
       100 Hz to 500 Hz, ≥10 A  
      Amps Frequency: Flexible Current Probe   
      Range5.0 Hz to 500.0 Hz  
      Resolution0.1 Hz  
      Accuracy0.5 % RD + 5 digits  
      Trigger Level5 Hz to 20 Hz, ≥25 A  
       20 Hz to 100 Hz, ≥20 A  
       100 Hz to 500 Hz, ≥25 A  
      Voltage Frequency   
      Range5.0 Hz to 500.0 Hz  
      Resolution0.1 Hz  
      Accuracy0.5 % RD + 5 digits  
      Trigger Level5 Hz to 20 Hz, ≥5 V  
       20 Hz to 100 Hz, ≥5 V  
       100 Hz to 500 Hz, ≥10 V  
      DC Power   
      Range600.0 kVA (600.0 V dc range)  
       1500 kVA (1500 V dc range)  
      Resolution0.1 kVA  
       1 kVA  
      Accuracy2 % RD + 2.0 kVA  
       2 % RD + 20 kVA  
      Resistance   
      Range600.0 Ω  
       6000 Ω  
       60.00 kΩ  
      Resolution0.1 Ω (≤600.0 Ω)  
       1 Ω (≤6000 Ω)  
       0.01 kΩ (≤60.00 kΩ)  
      Accuracy1 % RD + 5 digits  
      Capacitance   
      Range100.0 μF  
       1000 μF  
      Resolution0.1 μF (≤100.0 μF)  
       1 μF (≤1000 μF)  
      Accuracy1 % RD + 5 digits  
      Inrush Trigger Level5 A  
      Mechanical   
      Size (L x W x H)281 mm x 84 mm x 49 mm  
      Weight (with batteries)520 g  
      Jaw Opening34 mm  
      Flexible Current Probe Diameter7.5 mm  
      Flexible Current Probe Cable Length   
      (head to electronics connector)1.8 m  
      Environmental   
      Operating Temperature-10 °C to 50 °C  
      Storage Temperature-40 °C to 60 °C  
      Operating HumidityNon condensing (<10°C)  
       ≤90 % RH (at 10 °C to 30 °C)  
       ≤75 % RH (at 30 °C to 40 °C)  
       ≤45 % RH (at 40 °C to 50 °C)  
      Operating Altitude2000 m  
      Storage Altitude12 000 m  
      Ingress Protection (IP) RatingIEC 60529: IP54 non-operating  
      Electromagnetic Compatibility (EMC)   
      InternationalIEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A
       Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
      Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
      Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
      Korea (KCC)Class A equipment (Industrial Broadcast & Communications Equipment)
       Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
      USA (FCC)47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
      Safety   
      GeneralIEC 61010-1, Pollution Degree 2 
      MeasurementIEC 61010-2-032: CAT III 1500 V / CAT IV 600 V 
       IEC 61010-2-033: CAT III 1500 V / CAT IV 600 V 
      Wireless Radio   
      Radio frequency certificationFCC ID: T68-FBLE, IC: 6627A-FBLE 
      Wireless Radio Frequency Range2400 MHz to 2483.5 MHz  
      Output Power<100 mW  
      SIMPLIFIED EU DECLARATION OF CONFORMITY  
      Hereby, Fluke declares that the radio equipment contained in this Product is in compliance with Directive 2014/53/EU.
      The full text of the EU declaration is available at the following Internet address:  
      www.fluke.com/en-us/declaration-of-conformity   



      Specifications: Pomona PVLEAD1 and PVLEAD3 Solar PV Clamp Test Lead Set

       PVLEAD1PVLEAD3
      Solar PV Connector to 4mm Test Lead SetSolar PV Clamp Test Lead Set
      ContactBrass, Nickel PlatedBrass, Nickel Plated
      Length60”36”, 12”
      VoltageCAT III 1000V,CAT III 1000V,
      CAT IV 600VCAT IV 600V
      Current20 amp20 amp
      StandardsIEC 61010-031IEC 61010-031
      • bvseo_sdk, p_sdk, 3.2.1
      • CLOUD, getContent, 126.71ms
      • QUESTIONS, PRODUCT
      • bvseo-msg: HTTP status code of 404 was returned;
      • bvseo_sdk, p_sdk, 3.2.1
      • CLOUD, getReviews, 25.05ms
      • REVIEWS, PRODUCT
      • bvseo-msg: HTTP status code of 404 was returned;
      Please enable cookies to view product reviews.