Fluke 368 FC Leakage Current Clamp Meter

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 235.51ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • Fluke 368 FC Leakage Current Clamp Meter
  • Fluke 368 FC Leakage Current Clamp Meter
  • Fluke 368 FC Leakage Current Clamp Meter
  • Fluke 368 FC Leakage Current Clamp Meter
  • Fluke 368 FC Leakage Current Clamp Meter
  • Video Player is loading.
    Current Time 0:00
    Duration 0:46
    Loaded: 0%
    Stream Type LIVE
    Remaining Time 0:46
     
    1x
      • Chapters
      • descriptions off, selected
      • en (Main), selected
    1. Fluke 368 FC Leakage Current Clamp Meter
    2. Fluke 368 FC Leakage Current Clamp Meter
    3. Fluke 368 FC Leakage Current Clamp Meter
    4. Fluke 368 FC Leakage Current Clamp Meter
    5. Fluke 368 FC Leakage Current Clamp Meter
    6. Fluke 368 FC Leakage Current Clamp Meter

    Key features

    Read more

    Product overview: Fluke 368 FC Leakage Current Clamp Meter

    Reduce downtime – Find leakage currents without taking equipment offline.

    The Fluke 368 FC true-rms leakage current clamp meter helps users detect, document, record and compare leakage current readings over time as a means of preventing unplanned downtime, and identifying intermittent GFCI and RCD trips, all without taking equipment off line.

    The Fluke 368 FC has a large 40 mm diameter jaw for work with large conductors. The clamp’s jaw is fully shielded to accurately capture very small leakage signals, and to minimize external electromagnetic interference.

    The 368 FC also offers wireless data connectivity via Fluke Connect. As part of Fluke Connect — the industry’s largest system of software and more than 40 wireless test tools — the 368 FC allows you to track changes in leakage current over time, helping to identify potential problems before they turn into major failures.

    What's in the box:

    • 368 FC Leakage Clamp Meter
    • Soft case
    • 2 AA Batteries (Installed)
    • Quick Reference Guide

    Specifications: Fluke 368 FC Leakage Current Clamp Meter

    Electrical Specifications
    Measurement functionAlternating current
    AC ampere range3 mA, 30 mA, 300 mA, 3 A, 30 A, 60 A
     mA / A: manual selection
    3 mA / 30 mA / 300 mA: automatic selection
    3 A / 30 A / 60 A: automatic selection
    Range / Resolution3 mA¹ / 0.001 mA
    30 mA / 0.01 mA
    300 mA / 0.1 mA
    3 A / 0.001 A
    30 A / 0.01 A
    60 A / 0.1 A
    Accuracy – filter activated (40 to 70 Hz), filter off (40 to 1 kHz)²3 mA – 30 A
    60 A
    1% + 5 digits
    2% + 5 digits
    Frequency40 Hz to 1 kHz
    Crest Factor3
    After calibration accuracy is valid for one year. Accuracy is expressed as ± (% of reading + digits). Reference conditions 23 ±5 °C and a maximum relative humidity of 80%.
    ¹The minimum value is 10 μA rms.
    ²Outside of the TC / °C 18 °C to 28 °C, 0.02 + 1
    Physical
    Display (LCD)Digital readout: 3300 count
    Display refresh rate4 times / sec
    Maximum conductor diameter40 mm
    Dimensions234 x 101 x 46 mm
    Weight500 g
    Battery2 AA, IEC LR6, NEDA 15A, alkaline
    Battery lifeExpected battery life, without using backlight and spotlight, is more than 150 hours
    Automatic shut-downMeter automatically shuts down after 15 minutes of inactivity
    Safety and Environmental Specifications
    General safetyIEC 61010-1: Pollution Degree 2
    Measurement safetyIEC 61010-2-032: CAT III 600 V / CAT IV 300 V
    Operating temperature-10 °C to +50 °C
    Storage temperature-40 °C to +60 °C
    Operating humidityNon-condensing (<10 °C)
    90% relative humidity (10 °C to 30 °C)
    75% relative humidity (30 °C to 40 °C)
    45% relative humidity (40 °C to 50 °C)
    Protection classIEC 60529: IP30 (jaw closed)
    Operating altitude2000 m
    Storage altitude12000 m
    Current sensor action categoryIEC 61557-13: Class 2, ≤30 A / m
    Electromagnetic compatibility (EMC)
    International
    IEC 61326-1Industrial Electromagnetic Environment
    CISPR 11Group 1 Class B
    Group 1Generated inside the equipment and / or use radio frequency energy associated with conducting the energy for the device's own internal functions is essential.
    Class BEquipment for home appliances and residential buildings directly connected to a low voltage power supply network equipment. When this device is connected to a test object, it may exceed the emission levels produced by CISPR 11 requirements.
    Korea (KCC): A type of equipment (radio and communication equipment industry)
    Class AThis product meets the requirements of industrial electromagnetic equipment, vendors or users should be aware of this. This device is intended for use in a commercial environment, instead of the home environment.
    USA (FCC): 47 CFR 15 B Subpart. In accordance with section 15.103 provides that the products are considered tax-free device.

    Models: Fluke 368 FC Leakage Current Clamp Meter

    Fluke 368 FC
    Fluke 368 FC Leakage Current Clamp Meter

    Buy it

    Includes:

    • Leakage Clamp Meter
    • Soft case
    • Safety manual
    • Batteries: 2 AA
    • bvseo_sdk, p_sdk, 3.2.1
    • CLOUD, getContent, 134.87ms
    • QUESTIONS, PRODUCT
    • bvseo-msg: HTTP status code of 404 was returned;
    • bvseo_sdk, p_sdk, 3.2.1
    • CLOUD, getReviews, 23.33ms
    • REVIEWS, PRODUCT
    • bvseo-msg: HTTP status code of 404 was returned;
    Please enable cookies to view product reviews.