Fluke T+Pro Canada Electrical Tester

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 65.41ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • Fluke T+ Electrical Tester
  • Fluke T+ Electrical Tester
  • Fluke T+ Electrical Tester

Key features

  • Backlit LCD display for easier viewing
  • Display resolution of 0.1 V, ideal for troubleshooting low-voltage lighting
  • Resistance (Ohms) to 9.99 kOhms
  • Rotary Field Indication
  • Display Hold for easier viewing in hard-to-test areas
  • 3 forms of AC/DC voltage indication: light, sound, and vibration for added user protection and convenience
  • Detect live voltage even when the batteries are dead
  • Extra heavy-duty, replaceable test leads for more flexibility and durability
  • CAT IV 600 V, CAT III 1000 V rated for added user protection
  • Continuity beeper
  • Bright LED flashlight for work in poorly lit areas
  • GFCI Trip
  • On/Off switchable beeper, selectable according to your environment
  • Compliant with latest NFPA 70E recommendations*
  • Replaceable test probes for added flexibility and convenience
  • Convenient probe storage on the back
  • Probe holder for easier testing
  • Hazardous voltage warning light for added user protection
  • Test lead strap included for better test lead management
  • AC/DC Voltage: 12 V – 600 V on LED bar, 10.2 V – 600 V on LCD
  • Auto-off saves battery power
  • 2-year warranty

* When used properly per Article 110.9 Use of Equipment (A) Test Instruments and Equipment

Product overview: Fluke T+Pro Canada Electrical Tester

Safer than traditional solenoid testers and fully compliant with NFPA 70E*

The T+PRO Electrical Testers offer all the functionality that electricians look for in volt meters and voltage and continuity testers:

  • Three ways to detect AC/DC voltage: light, sound, and vibration
  • Added functionality of a GFCI trip and continuity beeper, plus the convenience of a built-in flashlight
  • The T+PRO Electrical Tester comes with a rotary field indicator for troubleshooting three-phase systems, resistance measurement to 9.99 KOhms, as well as a backlit LCD display for easier viewing

Safer than traditional solenoid testers:

  • Solid-state tester design
  • CAT IV 600 V, CAT III 1000 V rated
  • Complies with NFPA 70E*

The ruggedness and reliability that customers have come to expect from Fluke

* When used properly per Article 110.9 Use of Equipment (A) Test Instruments and Equipment.

Specifications: Fluke T+Pro Canada Electrical Tester

Specifications
TemperatureOperating-10°C to 55°C (14°F to 131°F)
Storage-30°C to 60°C (-22°F to 140°F)
Relative humidity90%0°C to 30°C (32°F to 86°F)
75%30°C to 40°C (86°F to 104°F)
45%40°C to 50°C (104°F to 122°F)
AltitudeOperating2,000 m (approx. 6,561.6 ft)
Storage10,000 m (approx. 32,808.4 ft)
Battery type/lifeAAA (2); 40 hours
Shock, vibrationSinusoidal vibration per MIL-PRF-28800F for a Class 2 instrument
SafetyISA-82.02.01 (IEC 61010-1 Mod) Second Edition, CAN/CSA-C22.2 No. 61010-1 Second Edition, IEC 61010 - 1 to 1000 V CAT III/600 V CAT IV
Compliance to NFPA 70E1
AC bandwidth45 Hz to 66 Hz
Maximum working Voltage1000 V AC/DC
Maximum measurable voltage600 V AC/DC
Duty cycleIndefinitely for voltages up to 240 V
For voltages between 240 V and 600 V the duty cycle is 30 s on / 300 s off
For voltages above 240 V the tester must connect to a voltage source only for a MAXIMUM of 30 s and then disconnect for a MINIMUM of 300 s
Voltage hazard LEDLEDs turn on at voltages > 30 V AC/DC ±35%
LED voltage indication levels12 V, 24 V, 48 V, 120 V, 208 V, 240 V, 347 V, 480 V, 600 V
LEDsLEDs turn on between 90% and 100% of the indicated voltage on the LED, except for the 12 V LED which turns on between 50% and 100%
LCD accuracyAC voltage±(3% rdg + 2 digits)
DC voltage±(2% rdg + 2 digits)
Resistance±(5% rdg + 3 digits)
LCD resolution0.1 V for voltages < 50 V, 1 V for voltages ≥ 50 V
0.01 kΩ for resistance measurement
GFCI test current100 V - 150 V @ 6 mA - 9 mA AC, 150 V - 240 V < 12 mA
Standard input test current< 5 mA
Size (H x W x L)1.3 x 2.15 x 7.6 in (3.3 x 5.46 x 19.3 cm )
Weight9.9 oz (0.28 kg)
1. When used properly per Article 110.9 Use of Equipment (A) Test Instruments and Equipment.

Models: Fluke T+Pro Canada Electrical Tester

Fluke T+PRO CAN
Fluke T+PRO Canada Electrical Tester

Buy it

Includes:

  • User manual
  • Test lead wrap
  • TP2 test probes

This model is only available in Canada

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 58.79ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 24.19ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.